The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays
Open accessAbstract
High-throughput genetic and phenotypic analysis at the single cell level is critical to advance our understanding of the molecular mechanisms underlying cellular function and dysfunction. Here we describe a high-performance single cell genetic analysis (SCGA) technique that combines high-throughput microfluidic emulsion generation with single cell multiplex polymerase chain reaction (PCR). Microfabricated emulsion generator array (MEGA) devices containing 4, 32, and 96 channels are developed to confer a flexible capability of generating up to 3.4 x 10(6) nanoliter-volume droplets per hour. Hybrid glass-polydimethylsiloxane diaphragm micropumps integrated into the MEGA chips afford uniform droplet formation, controlled generation frequency, and effective transportation and encapsulation of primer functionalized microbeads and cells. A multiplex single cell PCR method is developed to detect and quantify both wild type and mutant/pathogenic cells. In this method, microbeads functionalized with multiple forward primers targeting specific genes from different cell types are used for solid-phase PCR in droplets. Following PCR, the droplets are lysed and the beads are pooled and rapidly analyzed by multicolor flow cytometry. Using Escherichia coli bacterial cells as a model, we show that this technique enables digital detection of pathogenic E. coli O157 cells in a high background of normal K12 cells, with a detection limit on the order of 1/10(5). This result demonstrates that multiplex SCGA is a promising tool for high-throughput quantitative digital analysis of genetic variation in complex populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Stochastic Gene Expression in a Single Cell
Elowitz, M. B., Levine, A. J., Siggia, E. D., & Swain, P. S. (2002) · Science · doi:10.1126/science.1070919 · Cited by 5,441
Detection and quantification of mutations in the plasma of patients with colorectal tumors
Diehl, F., Li, M., Dressman, D., He, Y., Shen, D., Szabo, S., Diaz, L. A., Goodman, S. N., David, K. A., Juhl, H., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507904102 · Cited by 1,188
Stochastic protein expression in individual cells at the single molecule level
Cai, L., Friedman, N., & Xie, X. S. (2006) · Nature · doi:10.1038/nature04599 · Cited by 1,145
Sensitive digital quantification of DNA methylation in clinical samples
Li, M., Chen, W.-D., Papadopoulos, N., Goodman, S. N., Bjerregaard, N. C., Laurberg, S., Levin, B., Juhl, H., Arber, N., Moinova, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1559 · Cited by 341
BEAMing up for detection and quantification of rare sequence variants
Li, M., Diehl, F., Dressman, D., Vogelstein, B., & Kinzler, K. W. (2006) · Nature Methods · doi:10.1038/nmeth850 · Cited by 261
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
He, M., Crow, J., Roth, M., Zeng, Y., & Godwin, A. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00662c · Cited by 499
Self-citationFoudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
McHale, C. M., Zhang, L., & Smith, M. T. (2012) · Carcinogenesis · doi:10.1093/carcin/bgr297 · Cited by 345
Self-citationScaling by shrinking: empowering single-cell 'omics' with microfluidic devices
Prakadan, S. M., Shalek, A. K., & Weitz, D. A. (2017) · Nature Reviews Genetics · doi:10.1038/nrg.2017.15 · Cited by 325
1-Million droplet array with wide-field fluorescence imaging for digital PCR
Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20561g · Cited by 317
Droplets Formation and Merging in Two-Phase Flow Microfluidics
Gu, H., Duits, M. H. G., & Mugele, F. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12042572 · Cited by 312
The future is now: single-cell genomics of bacteria and archaea
Blainey, P. C. (2013) · FEMS Microbiology Reviews · doi:10.1111/1574-6976.12015 · Cited by 299
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
The role of physiological heterogeneity in microbial population behavior
Lidstrom, M. E., & Konopka, M. C. (2010) · Nature Chemical Biology · doi:10.1038/nchembio.436 · Cited by 296
Single‐Cell Analysis Using Droplet Microfluidics
Matuła, K., Rivello, F., & Huck, W. T. S. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900188 · Cited by 277
Micro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Isothermal Amplification Methods for the Detection of Nucleic Acids in Microfluidic Devices
Zanoli, L., & Spoto, G. (2012) · Biosensors · doi:10.3390/bios3010018 · Cited by 265
Development and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Kreutz, J. E., Munson, T., Huynh, T., Shen, F., Du, W., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac201658s · Cited by 148
Han, L., Zi, X., Garmire, L. X., Wu, Y., Weissman, S. M., Pan, X., & Fan, R. (2014) · Scientific Reports · doi:10.1038/srep06485 · Cited by 83
Digital PCR to Determine the number of Transcripts from Single Neurons after Patch-Clamp Recording
Faragó, N., Kocsis, Á. K., Lovas, S., Molnár, G., Boldog, E., Rózsa, M., Szemenyei, V., Vámos, E., Nagy, L. I., Tamás, G., et al. (2013) · BioTechniques · doi:10.2144/000114029 · Cited by 26
Metadata
- Authors
- Zeng, Y., Novak, R., Shuga, J., Smith, M. T., & Mathies, R. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-01
- Volume
- 82
- Issue
- 8
- Pages
- 3183-3190
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968579293
- Cited by
- 232
- References
- 6
- FWCI
- 18.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.