The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
1-Million droplet array with wide-field fluorescence imaging for digital PCR
Abstract
Digital droplet reactors are useful as chemical and biological containers to discretize reagents into picolitre or nanolitre volumes for analysis of single cells, organisms, or molecules. However, most DNA based assays require processing of samples on the order of tens of microlitres and contain as few as one to as many as millions of fragments to be detected. Presented in this work is a droplet microfluidic platform and fluorescence imaging setup designed to better meet the needs of the high-throughput and high-dynamic-range by integrating multiple high-throughput droplet processing schemes on the chip. The design is capable of generating over 1-million, monodisperse, 50 picolitre droplets in 2-7 minutes that then self-assemble into high density 3-dimensional sphere packing configurations in a large viewing chamber for visualization and analysis. This device then undergoes on-chip polymerase chain reaction (PCR) amplification and fluorescence detection to digitally quantify the sample's nucleic acid contents. Wide-field fluorescence images are captured using a low cost 21-megapixel digital camera and macro-lens with an 8-12 cm(2) field-of-view at 1× to 0.85× magnification, respectively. We demonstrate both end-point and real-time imaging ability to perform on-chip quantitative digital PCR analysis of the entire droplet array. Compared to previous work, this highly integrated design yields a 100-fold increase in the number of on-chip digitized reactors with simultaneous fluorescence imaging for digital PCR based assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Amplification of complex gene libraries by emulsion PCR
Williams, R., Peisajovich, S. G., Miller, O. J., Magdassi, S., Tawfik, D. S., & Griffiths, A. D. (2006) · Nature Methods · doi:10.1038/nmeth896 · Cited by 358
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Weaver, S., Dube, S., Mir, A., Qin, J., Sun, G., Ramakrishnan, R., Jones, R. C., & Livak, K. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.003 · Cited by 220
Novel real-time quantitative PCR test for trisomy 21
Zimmermann, B., Holzgreve, W., Wenzel, F., & Hahn, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.362 · Cited by 86
Research works printed but not linked: 46
- Taly, 2007, ChemBioChem, 8, 263, 10.1002/cbic.200600425 · DOI
- Griffiths, 2006, Trends Biotechnol., 24, 395, 10.1016/j.tibtech.2006.06.009 · DOI · Paper page
- Huebner, 2008, Lab Chip, 8, 1244, 10.1039/b806405a · DOI · Paper page
- Brouzes, 2009, Proc. Natl. Acad. Sci. U. S. A., 106, 14195, 10.1073/pnas.0903542106 · DOI · Paper page
- Baret, 2009, Med. Sci. (Paris), 25, 627, 10.1051/medsci/2009256-7627 · DOI
- Clausell-Tormos, 2008, Chem. Biol., 15, 427, 10.1016/j.chembiol.2008.04.004 · DOI · Paper page
- Schaerli, 2009, Mol. BioSyst., 5, 1392, 10.1039/b907578j · DOI
- Kiss, 2008, Anal. Chem., 80, 8975, 10.1021/ac801276c · DOI · Paper page
- Ottesen, 2006, Science, 314, 1464, 10.1126/science.1131370 · DOI · Paper page
- Sundberg, 2010, Anal. Chem., 82, 1546, 10.1021/ac902398c · DOI
- Hatch, 2011, Lab Chip, 11, 2509, 10.1039/c0lc00553c · DOI
- White, 2009, BMC Genomics, 10, 116, 10.1186/1471-2164-10-116 · DOI · Paper page
- Beer, 2007, Anal. Chem., 79, 8471, 10.1021/ac701809w · DOI · Paper page
- Zhong, 2011, Lab Chip, 11, 2167, 10.1039/c1lc20126c · DOI · Paper page
- Schaerli, 2009, Anal. Chem., 81, 302, 10.1021/ac802038c · DOI · Paper page
- Zeng, 2010, Anal. Chem., 82, 3183, 10.1021/ac902683t · DOI · Paper page
- Gan, 2008, Biotechnol. Prog., 24, 1107, 10.1002/btpr.43 · doi:10.1002/btpr.43
- Diehl, 2006, Nat. Methods, 3, 551, 10.1038/nmeth898 · DOI · Paper page
- Beer, 2008, Anal. Chem., 80, 1854, 10.1021/ac800048k · DOI · Paper page
- Nakano, 2005, J. Biosci. Bioeng., 99, 293, 10.1263/jbb.99.293 · DOI
- Hua, 2010, Anal. Chem., 82, 2310, 10.1021/ac902510u · DOI · Paper page
- Hori, 2007, Biochem. Biophys. Res. Commun., 352, 323, 10.1016/j.bbrc.2006.11.037 · DOI
- Sykes, 1992, BioTechniques, 13, 444
- Kim, 2009, Opt. Express, 17, 218, 10.1364/OE.17.000218 · DOI
- Sista, 2008, Lab Chip, 8, 2091, 10.1039/b814922d · DOI · Paper page
- Wittwer, 1997, BioTechniques, 22, 130, 10.2144/97221bi01 · DOI · Paper page
- Whitesides, 2001, Annu. Rev. Biomed. Eng., 3, 335, 10.1146/annurev.bioeng.3.1.335 · DOI · Paper page
- Xia, 1998, Annu. Rev. Mater. Sci., 28, 153, 10.1146/annurev.matsci.28.1.153 · DOI · Paper page
- Courtois, 2008, ChemBioChem, 9, 439, 10.1002/cbic.200700536 · DOI · Paper page
- Ostuni, 2000, Langmuir, 16, 7811, 10.1021/la000382m · DOI · Paper page
- Poussier, 2002, J. Microbiol. Methods, 51, 349, 10.1016/S0167-7012(02)00111-2 · doi:10.1016/s0167-7012(02)00111-2
- Courtois, 2009, Anal. Chem., 81, 3008, 10.1021/ac802658n · DOI · Paper page
- Beverung, 1999, Biophys. Chem., 81, 59, 10.1016/S0301-4622(99)00082-4 · DOI · Paper page
- Roach, 2005, Anal. Chem., 77, 785, 10.1021/ac049061w · DOI · Paper page
- Horakova, 2011, BMC Biotechnol., 11, 41, 10.1186/1472-6750-11-41 · DOI
- Sahoo, 1988, Comput. Vision Graphics Image Process., 41, 233, 10.1016/0734-189X(88)90022-9 · DOI · Paper page
- Lai, 2005, Clin. Chem., 51, 1132, 10.1373/clinchem.2004.039909 · DOI
- Morrison, 1998, BioTechniques, 24, 954
- Cikos, 2009, Anal. Biochem., 384, 1, 10.1016/j.ab.2008.08.031 · DOI
- Boggy, 2010, PLoS One, 5, e12355, 10.1371/journal.pone.0012355 · DOI
- El Gamal, 2005, IEEE Circuits Devices Mag., 21, 6, 10.1109/MCD.2005.1438751 · DOI · Paper page
- Vykoukal, 2009, Angew. Chem., Int. Ed., 48, 7649, 10.1002/anie.200901814 · DOI
- Shen, 2011, Sens. Actuators, B, 155, 430, 10.1016/j.snb.2011.01.001 · doi:10.1016/j.snb.2011.01.001
- Song, 2005, Biosens. Bioelectron., 20, 2203, 10.1016/j.bios.2004.08.033 · doi:10.1016/j.bios.2004.08.033
- Bubner, 2004, BMC Biotechnol., 4, 14, 10.1186/1472-6750-4-14 · DOI · Paper page
- Chapin, 1997, J. Clin. Microbiol., 35, 2157, 10.1128/JCM.35.8.2157-2159.1997 · doi:10.1128/jcm.35.8.2157-2159.1997
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Metadata
- Authors
- Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 22
- Pages
- 3838
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1988955440
- Cited by
- 317
- References
- 5
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1-Million droplet array with wide-field fluorescence imaging for digital PCR. https://app.cochat.ai/papers/10.1039/c1lc20561g
- The paper
- Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011). 1-Million droplet array with wide-field fluorescence imaging for digital PCR. Lab on a Chip. https://doi.org/10.1039/c1lc20561g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.