The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Analytical Properties of the Nanoelectrospray Ion Source
Abstract
The nanoelectrospray ion source (nanoES) has recently been developed and described theoretically. It is different from conventional electrospray sources and from other miniaturized electrospray sources by (i) its 1-2 microns spraying orifice achieved by pulling the spraying capillary to a fine tip, (ii) its very low flow rate of approximately 20 nL/min and the small size of droplets it generates, and (iii) the absence of solvent pumps and inlet valves. The fabrication and operation of nanoES needles is described in detail. Solutions with up to 0.1 M salt contents could be sprayed without sheath flow or pneumatic assist. Improved desolvation in nanoES led to instrument-limited resolution of the signals of a glycoprotein and the ability to signal average extensively allowed the C-terminal sequencing of a 40 kDa protein. Extensive mass spectrometric and tandem mass spectrometric investigation of the components of an unseparated peptide mixture was demonstrated by verification of 93% of the sequence of carbonic anhydrase. A rapid and robust desalting/concentration step coupled to the nanoES procedure allows the direct analysis of impure samples such as peptide mixtures extracted after in-gel digestion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Self-citationInt. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationMicro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Some Developments in Nuclear Magnetic Resonance of Solids
Chmelka, B. F., & Pines, A. (1989) · Science · doi:10.1126/science.246.4926.71 · Cited by 379
Photovoltage of rods and cones in the macaque retina
Schneeweis, D., & Schnapf, J. (1995) · Science · doi:10.1126/science.7754386 · Cited by 334
Smith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Cited by
Items 101–104 of 104
Wang, X., Yan, S., Dai, W., Liu, X., Zhang, W., & Wang, J. (2010) · International Journal of Cancer · doi:10.1002/ijc.25294 · Cited by 26
Structural insights into binding-site access and ligand recognition by human ABCB1
Kurre, D., Dang, P. X., Le, L. T. M., Gadkari, V. V., & Alam, A. (2025) · The EMBO Journal · doi:10.1038/s44318-025-00361-z · Cited by 25
(2022) · doi:10.3390/proteomes10030026 · Cited by 20
CICEK, G., SCHILTZ, E., HESS, D., STAIGER, J., & BRANDSCH, R. (2002) · Clinical and Experimental Immunology · doi:10.1046/j.1365-2249.2002.01816.x · Cited by 11
Metadata
- Authors
- Wilm, M., & Mann, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031884770
- Cited by
- 1,868
- References
- 14
- FWCI
- 53.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.