The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Analytical Properties of the Nanoelectrospray Ion Source
Abstract
The nanoelectrospray ion source (nanoES) has recently been developed and described theoretically. It is different from conventional electrospray sources and from other miniaturized electrospray sources by (i) its 1-2 microns spraying orifice achieved by pulling the spraying capillary to a fine tip, (ii) its very low flow rate of approximately 20 nL/min and the small size of droplets it generates, and (iii) the absence of solvent pumps and inlet valves. The fabrication and operation of nanoES needles is described in detail. Solutions with up to 0.1 M salt contents could be sprayed without sheath flow or pneumatic assist. Improved desolvation in nanoES led to instrument-limited resolution of the signals of a glycoprotein and the ability to signal average extensively allowed the C-terminal sequencing of a 40 kDa protein. Extensive mass spectrometric and tandem mass spectrometric investigation of the components of an unseparated peptide mixture was demonstrated by verification of 93% of the sequence of carbonic anhydrase. A rapid and robust desalting/concentration step coupled to the nanoES procedure allows the direct analysis of impure samples such as peptide mixtures extracted after in-gel digestion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Self-citationInt. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationMicro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Some Developments in Nuclear Magnetic Resonance of Solids
Chmelka, B. F., & Pines, A. (1989) · Science · doi:10.1126/science.246.4926.71 · Cited by 379
Photovoltage of rods and cones in the macaque retina
Schneeweis, D., & Schnapf, J. (1995) · Science · doi:10.1126/science.7754386 · Cited by 334
Smith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Cited by
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Sakurai, T., Amemiya, A., Ishii, M., Matsuzaki, I., Chemelli, R. M., Tanaka, H., Williams, S. C., Richardson, J. A., Kozlowski, G. P., Wilson, S., et al. (1998) · Cell · doi:10.1016/s0092-8674(00)80949-6 · Cited by 5,501
Rappsilber, J., Mann, M., & Ishihama, Y. (2007) · Nature Protocols · doi:10.1038/nprot.2007.261 · Cited by 4,641
Self-citationMuzio, M., Chinnaiyan, A. M., Kischkel, F. C., O'Rourke, K., Shevchenko, A., Ni, J., Scaffidi, C., Bretz, J. D., Zhang, M., Gentz, R., et al. (1996) · Cell · doi:10.1016/s0092-8674(00)81266-0 · Cited by 3,046
Self-citationProteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
Self-citationIKK-1 and IKK-2: Cytokine-Activated IκB Kinases Essential for NF-κB Activation
Mercurio, F., Zhu, H., Murray, B. W., Shevchenko, A., Bennett, B. L., Li, J. W., Young, D. B., Barbosa, M., Mann, M., Manning, A., et al. (1997) · Science · doi:10.1126/science.278.5339.860 · Cited by 2,040
Self-citationFemtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,680
Self-citationProtein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Self-citationCarrageenans: Biological properties, chemical modifications and structural analysis – A review
Campo, V. L., Kawano, D. F., Silva, D. B. D., & Carvalho, I. (2009) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2009.01.020 · Cited by 1,403
Reverse Transcriptase Motifs in the Catalytic Subunit of Telomerase
Lingner, J., Hughes, T. R., Shevchenko, A., Mann, M., Lundblad, V., & Cech, T. R. (1997) · Science · doi:10.1126/science.276.5312.561 · Cited by 1,269
Self-citationMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Self-citationFLICE is activated by association with the CD95 death-inducing signaling complex (DISC)
Medema, J. P. (1997) · The EMBO Journal · doi:10.1093/emboj/16.10.2794 · Cited by 1,188
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Brügger, B., Erben, G., Sandhoff, R., Wieland, F. T., & Lehmann, W. D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.6.2339 · Cited by 881
Proteomics: quantitative and physical mapping of cellular proteins
Blackstock, W. P., & Weir, M. P. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(98)01245-1 · Cited by 873
AU Binding Proteins Recruit the Exosome to Degrade ARE-Containing mRNAs
Chen, C.-Y., Gherzi, R., Ong, S.-E., Chan, E. L., Raijmakers, R., Pruijn, G. J. M., Stoecklin, G., Moroni, C., Mann, M., & Karin, M. (2001) · Cell · doi:10.1016/s0092-8674(01)00578-5 · Cited by 865
Self-citationCohesin’s binding to chromosomes depends on a separate complex consisting of Scc2 and Scc4 proteins
Ciosk, R., Shirayama, M., Shevchenko, A., Tanaka, T., Toth, A., Shevchenko, A., & Nasmyth, K. (2000) · Molecular Cell · doi:10.1016/s1097-2765(00)80420-7 · Cited by 755
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Sinz, A. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20082 · Cited by 648
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“This lower flow rate ESI, termed nanoESI [35], is highly advantageous for native MS analysis because of its low sample consumption, more uniform response factors, and higher tolerance to salts and buffers.”
BackgroundCurrent approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
The dynamic range of protein expression: A challenge for proteomic research
Corthals, G. L., Wasinger, V. C., Hochstrasser, D. F., & Sanchez, J.-C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1104::aid-elps1104>3.0.co;2-c · Cited by 619
Ciosk, R., Zachariae, W., Michaelis, C., Shevchenko, A., Mann, M., & Nasmyth, K. (1998) · Cell · doi:10.1016/s0092-8674(00)81211-8 · Cited by 593
Self-citationInvestigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Target profiling of small molecules by chemical proteomics
Rix, U., & Superti-Furga, G. (2009) · Nature Chemical Biology · doi:10.1038/nchembio.216 · Cited by 575
A New Yeast Poly(A) Polymerase Complex Involved in RNA Quality Control
Vaňáčová, Š., Wolf, J., Martin, G., Blank, D., Dettwiler, S., Friedlein, A., Langen, H., Keith, G., & Keller, W. (2005) · PLoS Biology · doi:10.1371/journal.pbio.0030189 · Cited by 567
TAP, the human homolog of Mex67p, mediates CTE-dependent RNA export from the nucleus
Grüter, P., Tabernero, C., von Kobbe, C., Schmitt, C., Saavedra, C., Bachi, A., Wilm, M., Felber, B. K., & Izaurralde, E. (1998) · Molecular Cell · doi:10.1016/s1097-2765(00)80065-9 · Cited by 560
Self-citationUltra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
Self-citationSchmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Gln 63 of Rho is deamidated by Escherichia coli cytotoxic necrotizing factor-1
Schmidt, G., Sehr, P., Wilm, M., Selzer, J., Mann, M., & Aktories, K. (1997) · Nature · doi:10.1038/42735 · Cited by 530
Self-citationOstareck, D. H., Ostareck-Lederer, A., Wilm, M., Thiele, B. J., Mann, M., & Hentze, M. W. (1997) · Cell · doi:10.1016/s0092-8674(00)80241-x · Cited by 502
Self-citationBera, A., Herbert, S., Jakob, A., Vollmer, W., & Götz, F. (2005) · Molecular Microbiology · doi:10.1111/j.1365-2958.2004.04446.x · Cited by 481
Brdic̆ka, T., Pavlis̆tová, D., Leo, A., Bruyns, E., Kor̆ínek, V., Angelisová, P., Scherer, J., Shevchenko, A., Shevchenko, A., Hilgert, I., et al. (2000) · The Journal of Experimental Medicine · doi:10.1084/jem.191.9.1591 · Cited by 461
Phosphorylation of Sic1p by G 1 Cdk Required for Its Degradation and Entry into S Phase
Verma, R., Annan, R. S., Huddleston, M. J., Carr, S. A., Reynard, G., & Deshaies, R. J. (1997) · Science · doi:10.1126/science.278.5337.455 · Cited by 449
Meyer, H. H., Shorter, J. G., Seemann, J., Pappin, D., & Warren, G. (2000) · The EMBO Journal · doi:10.1093/emboj/19.10.2181 · Cited by 445
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
The Mex67p-mediated nuclear mRNA export pathway is conserved from yeast to human
Katahira, J., Sträßer, K., Podtelejnikov, A., Mann, M., Jung, J. U., & Hurt, E. (1999) · The EMBO Journal · doi:10.1093/emboj/18.9.2593 · Cited by 441
Self-citationDestoumieux, D., Bulet, P., Loew, D., Van Dorsselaer, A., Rodriguez, J., & Bachère, E. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.45.28398 · Cited by 441
Molecular Mechanism for the Regulation of Protein Kinase B/Akt by Hydrophobic Motif Phosphorylation
Yang, J., Cron, P., Thompson, V., Good, V. M., Hess, D., Hemmings, B. A., & Barford, D. (2002) · Molecular Cell · doi:10.1016/s1097-2765(02)00550-6 · Cited by 418
Nanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Seol, J. H., Feldman, R. M. R., Zachariae, W., Shevchenko, A., Correll, C. C., Lyapina, S., Chi, Y., Galova, M., Claypool, J., Sandmeyer, S., et al. (1999) · Genes & Development · doi:10.1101/gad.13.12.1614 · Cited by 407
Pandey, A., Podtelejnikov, A. V., Blagoev, B., Bustelo, X. R., Mann, M., & Lodish, H. F. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.1.179 · Cited by 406
Self-citationNielsen, E., Christoforidis, S., Uttenweiler-Joseph, S., Miaczynska, M., Dewitte, F., Wilm, M., Hoflack, B., & Zerial, M. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.151.3.601 · Cited by 383
Self-citationHanger, D. P., Betts, J. C., Loviny, T. L. F., Blackstock, W. P., & Anderton, B. H. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.71062465.x · Cited by 377
Tpx2, a Novel Xenopus Map Involved in Spindle Pole Organization
Wittmann, T., Wilm, M., Karsenti, E., & Vernos, I. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.149.7.1405 · Cited by 377
Self-citationPHAX, a Mediator of U snRNA Nuclear Export Whose Activity Is Regulated by Phosphorylation
Ohno, M., Segref, A., Bachi, A., Wilm, M., & Mattaj, I. W. (2000) · Cell · doi:10.1016/s0092-8674(00)80829-6 · Cited by 374
Self-citationMechanistic aspects of electrospray ionization
Bruins, A. P. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01110-2 · Cited by 368
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
The Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Single-cell Proteomics: Progress and Prospects
Kelly, R. T. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r120.002234 · Cited by 356
The emerging landscape of single-molecule protein sequencing technologies
Alfaro, J. A., Bohländer, P., Dai, M., Filius, M., Howard, C. J., van Kooten, X. F., Ohayon, S., Pomorski, A., Schmid, S., Aksimentiev, A., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01143-1 · Cited by 351
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Internal energy and fragmentation of ions produced in electrospray sources
Gabelica, V., & Pauw, E. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20027 · Cited by 338
Achsel, T. (1999) · The EMBO Journal · doi:10.1093/emboj/18.20.5789 · Cited by 337
Tackling the plant proteome: practical approaches, hurdles and experimental tools
Rose, J. K. C., Bashir, S., Giovannoni, J. J., Jahn, M. M., & Saravanan, R. S. (2004) · The Plant Journal · doi:10.1111/j.1365-313x.2004.02182.x · Cited by 330
Phosphoproteome analysis of the human mitotic spindle
Nousiainen, M., Silljé, H. H. W., Sauer, G., Nigg, E. A., & Körner, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507066103 · Cited by 324
Regulation of G2/M events by Cdc25A through phosphorylation‐dependent modulation of its stability
Mailand, N., Podtelejnikov, A. V., Groth, A., Mann, M., Bartek, J., & Lukas, J. (2002) · The EMBO Journal · doi:10.1093/emboj/cdf567 · Cited by 315
Self-citationStatus of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Principles of Electrospray Ionization
Wilm, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009407 · Cited by 311
Self-citationHigh-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Staubitz, A., Sloan, M. E., Robertson, A. P. M., Friedrich, A., Schneider, S., Gates, P. J., Schmedt auf der Günne, J., & Manners, I. (2010) · Journal of the American Chemical Society · doi:10.1021/ja104607y · Cited by 302
Spindle Checkpoint Protein Xmad1 Recruits Xmad2 to Unattached Kinetochores
Chen, R.-H., Shevchenko, A., Mann, M., & Murray, A. W. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.143.2.283 · Cited by 301
Self-citationStrategies for analysis of glycoprotein glycosylation
Geyer, H., & Geyer, R. (2006) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2006.10.007 · Cited by 299
Schmitt, C. (1999) · The EMBO Journal · doi:10.1093/emboj/18.15.4332 · Cited by 289
Hopfgartner, G., Varesio, E., Tschäppät, V., Grivet, C., Bourgogne, E., & Leuthold, L. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.659 · Cited by 287
Nguyen, H. P., & Schug, K. A. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700630 · Cited by 275
Charroux, B., Pellizzoni, L., Perkinson, R. A., Shevchenko, A., Mann, M., & Dreyfuss, G. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.147.6.1181 · Cited by 274
Self-citationProtein identification: The origins of peptide mass fingerprinting
Henzel, W. J., Watanabe, C., & Stults, J. T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00214-9 · Cited by 268
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Ionization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.018 · Cited by 265
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Activation of a Novel Calcium-dependent Protein-tyrosine Kinase
Yu, H., Li, X., Marchetto, G. S., Dy, R., Hunter, D., Calvo, B., Dawson, T. L., Wilm, M., Anderegg, R. J., Graves, L. M., et al. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.47.29993 · Cited by 262
Self-citationGao, L., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac800014v · Cited by 258
Protein-Based Biological Materials: Molecular Design and Artificial Production
Miserez, A., Yu, J., & Mohammadi, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00621 · Cited by 257
Fragmentation of phosphopeptides in an ion trap mass spectrometer
DeGnore, J. P., & Qin, J. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00088-9 · Cited by 257
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Zhu, Y., Dou, M., Piehowski, P. D., Liang, Y., Wang, F., Chu, R. K., Chrisler, W. B., Smith, J. N., Schwarz, K. C., Shen, Y., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000686 · Cited by 147
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Fort, K. L., van de Waterbeemd, M., Boll, D., Reinhardt-Szyba, M., Belov, M. E., Sasaki, E., Zschoche, R., Hilvert, D., Makarov, A. A., & Heck, A. J. R. (2018) · The Analyst · doi:10.1039/c7an01629h · Cited by 122
Ancient Biomolecules and Evolutionary Inference
Cappellini, E., Prohaska, A., Racimo, F., Welker, F., Pedersen, M. W., Allentoft, M. E., de Barros Damgaard, P., Gutenbrunner, P., Dunne, J., Hammann, S., et al. (2018) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-062917-012002 · Cited by 118
Wang, H., Yang, Y., Li, Y., Bai, B., Wang, X., Tan, H., Liu, T., Beach, T. G., Peng, J., & Wu, Z. (2015) · Journal of Proteome Research · doi:10.1021/pr500882h · Cited by 96
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
Vowinckel, J., Zelezniak, A., Kibler, A., Bruderer, R., Muelleder, M., Reiter, L., & Ralser, M. (2016) · doi:10.1101/073478 · Cited by 81
Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00479 · Cited by 74
Unique insights to intrinsically disordered proteins provided by ion mobility mass spectrometry
Stuchfield, D., & Barran, P. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.01.007 · Cited by 72
c-Abl Phosphorylates Hdmx and Regulates Its Interaction with p53
Zuckerman, V., Lenos, K., Popowicz, G. M., Silberman, I., Grossman, T., Marine, J.-C., Holak, T. A., Jochemsen, A. G., & Haupt, Y. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m809211200 · Cited by 68
Native vs Denatured: An in Depth Investigation of Charge State and Isotope Distributions
Kafader, J. O., Melani, R. D., Schachner, L. F., Ives, A. N., Patrie, S. M., Kelleher, N. L., & Compton, P. D. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00040 · Cited by 51
Zhu, Y., Piehowski, P. D., Kelly, R. T., & Qian, W.-J. (2018) · Expert Review of Proteomics · doi:10.1080/14789450.2018.1537787 · Cited by 50
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48
Konijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43
Metadata
- Authors
- Wilm, M., & Mann, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031884770
- Cited by
- 1,868
- References
- 14
- FWCI
- 53.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.