CoChat

In Vivo Brain Glucose Measurements: Differential Normal Pulse Voltammetry with Enzyme-Modified Carbon Fiber Microelectrodes

Netchiporouk, Larissa I., Shram, Nataliya F., Jaffrezic-Renault, Nicole, Martelet, Claude, Cespuglio, Raymond · 1996 · Analytical Chemistry
Cited by 94

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The enzyme glucose oxidase was immobilized on the surface of carbon fiber microelectrodes (CFMEs) either by cross-linking in glutaraldehyde vapor or by enzyme entrapment in electropolymerized films of m-phenylenediamine or resorcinol. The cross-linked enzymatic layer was, in the given conditions, covered with an additional membrane of Nafion or cellulose acetate. The prepared glucose sensors were tested using differential normal pulse voltammetry (DNPV, in which the scan comprises successive double pulses ("prepulse and pulse"), the prepulses are of increasing amplitude, and the current measured is the differential of the current existing between each prepulse and pulse). With properly chosen DNPV parameters, the response to glucose presented a peak at a potential of about 1 V versus an Ag/AgC1-reference, owing to the oxidation of enzymatically produced hydrogen peroxide. The calibration curves obtained (peak height/glucose concentration) were linear from 0.3-0.5 up to 1.5-6.5 mM and showed a sensitivity ranging from 1.4 up to 34.5 mA M-1 cm-2, depending on the sensor type. The DNPV response to glucose exhibited an essential insensitivity toward easily oxidizable interfering substances such as ascorbic acid and acetaminophen present at physiological concentrations. Peptides, the interfering species typical of the cerebral medium, were effectively retained by the above additional membranes. Concentration values of glucose in plasma and cerebrospinal fluid, determined in vitro from the DNPV peak height, agreed well with those measured by standard procedures. In the anesthetized rat, extracellular brain concentration of glucose was also monitored during administration of either insulin or glucagon. Under such pharmacological conditions, the changes observed in the peak height were in perfect agreement with the known effects induced by both substances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac960190p

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Netchiporouk, L. I., Shram, N. F., Jaffrezic-Renault, N., Martelet, C., & Cespuglio, R.
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
24
Pages
4358-4364
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2052148264
Cited by
94
References
1
FWCI
2.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.