CoChat

Solvent Microextraction as a Speciation Tool: Determination of Free Progesterone in a Protein Solution

Jeannot, Michael A., Cantwell, Frederick F. · 1997 · Analytical Chemistry
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A 1-microL drop of n-octane suspended from the tip of a microsyringe needle in 500 mL of stirred aqueous solution is used to extract unbound progesterone in the presence of 1% (w/v) bovine serum albumin (BSA) for analysis by gas chromatography (GC). The observed extraction kinetics are in good agreement with a proposed convective-diffusive mass transfer model which accounts for diffusion of both free and bound species in the aqueous Nernst diffusion film adjacent to the interface. The equilibrium binding constant, which can be measured both at equilibrium and at nonequilibrium extraction times, is in good agreement with literature values. The very small phase ratio employed (i.e., 2 x 10(-6) mL of organic/mL of water) avoids perturbation of the aqueous solution equilibria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac970207j

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Jeannot, M. A., & Cantwell, F. F.
Venue
Analytical Chemistry
Published
1997-08-01
Volume
69
Issue
15
Pages
2935-2940
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2076990354
Cited by
152
References
1
FWCI
2.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.