Bioelectrochemical Monitoring of Phenols and Aromatic Amines in Flow Injection Using Novel Plant Peroxidases
The DOI matches its Crossref record.
Abstract
An amperometric flow system combined with a glucose oxidase-mutarotase reactor was optimized and used to determine aromatic amines and phenols using peroxidase-modified graphite electrodes. An increase in currents upon injection of the analyzed substrate was shown to be approximated by a Michaelis-Menten type dependence. The detection limit was calculated as 3 times the noise, and the sensitivity was calculated as Imax/K(m)app. Commercially available horseradish peroxidase was compared with tobacco anionic and peanut cationic peroxidases for determination of aromatic amines and phenols. Detection limits of 10 nM for determination of o-aminophenol and o- and p-phenylenediamine achieved with a tobacco peroxidase-modified electrode give a promise for further improvements in sensitivities and detection limits of biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanotechnology applications in pollution sensing and degradation in agriculture: a review
Baruah, S., & Dutta, J. (2009) · Environmental Chemistry Letters · doi:10.1007/s10311-009-0228-8 · Cited by 387
Extraction and Analysis of Polyphenols: Recent trends
Ajila, C. M., Brar, S. K., Verma, M., Tyagi, R. D., Godbout, S., & Valéro, J. R. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.513677 · Cited by 354
Potential applications of peroxidases
Hamid, M., & Khalil-ur-Rehman (2009) · Food Chemistry · doi:10.1016/j.foodchem.2009.02.035 · Cited by 312
Laccase-based biosensors for detection of phenolic compounds
Rodríguez-Delgado, M. M., Alemán-Nava, G. S., Rodríguez-Delgado, J. M., Dieck-Assad, G., Martínez-Chapa, S. O., Barceló, D., & Parra, R. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.05.008 · Cited by 302
Castillo, J., Gáspár, S., Leth, S., Niculescu, M., Mortari, A., Bontidean, I., Soukharev, V., Dorneanu, S. A., Ryabov, A. D., & Csöregi, E. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.04.084 · Cited by 272
Self-citation
Metadata
- Authors
- Munteanu, F.-D., Lindgren, A., Emnéus, J., Gorton, L., Ruzgas, T., Csöregi, E., Ciucu, A., van Huystee, R. B., Gazaryan, I. G., & Lagrimini, L. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-05-09
- Volume
- 70
- Issue
- 13
- Pages
- 2596-2600
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2003534913
- Cited by
- 120
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioelectrochemical Monitoring of Phenols and Aromatic Amines in Flow Injection Using Novel Plant Peroxidases. https://app.cochat.ai/papers/10.1021/ac980022s
- The paper
- Munteanu, F.-D., Lindgren, A., Emnéus, J., Gorton, L., Ruzgas, T., Csöregi, E., Ciucu, A., van Huystee, R. B., Gazaryan, I. G., & Lagrimini, L. M. (1998). Bioelectrochemical Monitoring of Phenols and Aromatic Amines in Flow Injection Using Novel Plant Peroxidases. Analytical Chemistry. https://doi.org/10.1021/ac980022s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.