Anthraquinonedisulfonate Electrochemistry: A Comparison of Glassy Carbon, Hydrogenated Glassy Carbon, Highly Oriented Pyrolytic Graphite, and Diamond Electrodes

Xu, Jishou, Chen, Qingyun, Swain, Greg M. · 1998 · Analytical Chemistry

Abstract

The electrochemistry of anthraquinone-2,6-disulfonate (2,6-AQDS) at glassy carbon (GC), hydrogenated glassy carbon (HGC), the basal plane of highly oriented pyrolytic graphite (HOPG), and boron-doped diamond was investigated by cyclic voltammetry and chronocoulometry. Quantitative determination of the surface coverage and qualitative assessment of the physisorption strength of 2,6-AQDS adsorption on each of these electrodes were done. The diamond and HGC surfaces are nonpolar and relatively oxygen-free, with the surface carbon atoms terminated by hydrogen. The polar 2,6-AQDS does not adsorb on these surfaces, and the electrolysis proceeds by a diffusion-controlled reaction. Conversely, the GC and HOPG surfaces are polar, with the exposed defect sites terminated by carbon-oxygen functionalities. 2,6-AQDS strongly physisorbs on both of these surfaces at near monolayer or greater coverages, such that the electrolysis proceeds through a surface-confined state. Less than 40% of the initial surface coverage can be removed by rinsing and solution replacement, reflective of strong physisorption. The results show the important role of the surface carbon-oxygen functionalities in promoting strong dipole-dipole and ion-dipole interactions with polar and ionic molecules such as 2,6-AQDS. The results also support the theory that diamond electrodes may be less subject to fouling by polar adsorbates, as compared to GC, leading to improved response stability in electroanalytical measurements. The relationship between the 2,6-AQDS surface coverage, the double-layer capacitance, and the heterogeneous electron-transfer rate constant for Fe(CN)(6)(3)(-)(/4)(-) for these four carbon electrodes is presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9800661

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 252

Metadata

Authors
Xu, J., Chen, Q., & Swain, G. M.
Venue
Analytical Chemistry
Published
1998-06-23
Volume
70
Issue
15
Pages
3146-3154
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2081749592
Cited by
252
References
10
FWCI
9.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anthraquinonedisulfonate Electrochemistry: A Comparison of Glassy Carbon, Hydrogenated Glassy Carbon, Highly Oriented Pyrolytic Graphite, and Diamond Electrodes. https://app.cochat.ai/papers/10.1021/ac9800661
The paper
Xu, J., Chen, Q., & Swain, G. M. (1998). Anthraquinonedisulfonate Electrochemistry: A Comparison of Glassy Carbon, Hydrogenated Glassy Carbon, Highly Oriented Pyrolytic Graphite, and Diamond Electrodes. Analytical Chemistry. https://doi.org/10.1021/ac9800661

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.