The DOI matches its Crossref record.
Electrodeposited Iridium Oxide pH Electrode for Measurement of Extracellular Myocardial Acidosis during Acute Ischemia
Abstract
In the present paper, fabrication, characterization, and physiological applications of a solid-state pH electrode are described. The pH sensing layer was based on an anodic electrodeposited iridium oxide film (AEIROF). Sputtered platinum electrodes (1 mm diameter) fabricated on flexible Kapton films or platinum wires were used as planar or cylindrical supports. Each electrode site was coated with Nafion to attenuate the interference of anionic redox species and to protect the electrode surface during in vivo measurements. Performance of the AEIROF was evaluated, for the first time, as a pH electrode and proved to have a slightly super-Nernstian response with slope of -63.5 +/- 2.2 mV/pH unit for both wire and planar sputtered platinum electrodes. Linear pH responses were obtained in the pH range 2-10. The electrodes have a working lifetime of at least 1 month with accuracy of about 0.02 pH unit and fast response time. The electrodes showed very low sensitivities for different species, such as Na+, K+, Li+, NH4+, Ca2+, Mg2+, dissolved oxygen, lactate, ascorbate, and urate, which are important for physiological applications. The electrodes were applied in extracellular pH measurements during brief regional ischemia in a swine heart and no-flow ischemia in an isolated rabbit papillary muscle. A first report on extracellular pH, K+, and lactate simultaneous measurements during no-flow ischemia using the AEIROF pH electrode and the previously described K+ and lactate electrodes is presented as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 481
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255
Mailley, S. C., Hyland, M., Mailley, P., McLaughlin, J. M., & McAdams, E. T. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00098-x · Cited by 84
Metadata
- Authors
- Marzouk, S. A. M., Ufer, S., Buck, R. P., Johnson, T. A., Dunlap, L. A., & Cascio, W. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-24
- Volume
- 70
- Issue
- 23
- Pages
- 5054-5061
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089791650
- Cited by
- 219
- References
- 0
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.