Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 601

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Strategy for the Generation of Surfaces Presenting Ligands for Studies of Binding Based on an Active Ester as a Common Reactive Intermediate: A Surface Plasmon Resonance Study

Lahiri, Joydeep, Isaacs, Lyle, Tien, Joe, Whitesides, George M.·1999·Analytical Chemistry

Abstract

This paper describes the immobilization of ten proteins and two low-molecular-weight ligands on mixed self-assembled monolayers (SAMs) of alkanethiolates on gold generated from the tri(ethylene glycol)-terminated thiol 1 (HS(CH2)11(OCH2CH2)3OH) (chi(1) = 1.0-0.0) and the longer, carboxylic acid-terminated thiol2(HS(CH2)11(OCH2-CH2)6OCH2CO2H) (chi(2) = 0.0-1.0). The immobilization was achieved by a two-step procedure: generation of reactive N-hydroxysuccinimidyl esters from the carboxylic acid groups of 2 in the SAM and coupling of these groups with amines on the protein or ligand. Because this method involves a common reactive intermediate that is easily prepared, it provides a convenient method for attaching ligands to SAMs for studies using surface plasmon resonance spectroscopy (and, in principle, other bioanalytical methods that use derivatized SAMs on gold, silver, and other surfaces). These SAMs were resistant to nonspecific adsorption of proteins having a wide range of molecular weights and isoelectric points. The pH of the coupling buffer, the concentration of protein, the ionic strength of the solution of protein, and the molecular weight of the protein all influenced the amount of the protein that was immobilized. For the proteins investigated in detail--carbonic anhydrase and lysozyme--the highest quantities of immobilized proteins were obtained when using a low ionic strength solution at a value of pH approximately one unit below the isoelectric point (pI) of the protein, at a concentration of approximately 0.5 mg mL-1. Comparisons of the kinetic and thermodynamic constants describing binding of carbonic anhydrase and vancomycin to immobilized benzenesulfonamide and N-alpha-Ac-Lys-D-Ala-D-Ala groups, respectively, on mixed SAMs (by methods described in this paper) and in the carboxymethyl dextran matrix of commercially available substrates yielded (for these systems) essentially indistinguishable values of Kd, koff, and kon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac980959t

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 601

Metadata

Authors
Lahiri, J., Isaacs, L., Tien, J., & Whitesides, G. M.
Venue
Analytical Chemistry
Published
1999-01-08
Volume
71
Issue
4
Pages
777-790
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2047917567
Cited by
601
References
1
FWCI
21.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.