The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Strategy for the Generation of Surfaces Presenting Ligands for Studies of Binding Based on an Active Ester as a Common Reactive Intermediate: A Surface Plasmon Resonance Study
Abstract
This paper describes the immobilization of ten proteins and two low-molecular-weight ligands on mixed self-assembled monolayers (SAMs) of alkanethiolates on gold generated from the tri(ethylene glycol)-terminated thiol 1 (HS(CH2)11(OCH2CH2)3OH) (chi(1) = 1.0-0.0) and the longer, carboxylic acid-terminated thiol2(HS(CH2)11(OCH2-CH2)6OCH2CO2H) (chi(2) = 0.0-1.0). The immobilization was achieved by a two-step procedure: generation of reactive N-hydroxysuccinimidyl esters from the carboxylic acid groups of 2 in the SAM and coupling of these groups with amines on the protein or ligand. Because this method involves a common reactive intermediate that is easily prepared, it provides a convenient method for attaching ligands to SAMs for studies using surface plasmon resonance spectroscopy (and, in principle, other bioanalytical methods that use derivatized SAMs on gold, silver, and other surfaces). These SAMs were resistant to nonspecific adsorption of proteins having a wide range of molecular weights and isoelectric points. The pH of the coupling buffer, the concentration of protein, the ionic strength of the solution of protein, and the molecular weight of the protein all influenced the amount of the protein that was immobilized. For the proteins investigated in detail--carbonic anhydrase and lysozyme--the highest quantities of immobilized proteins were obtained when using a low ionic strength solution at a value of pH approximately one unit below the isoelectric point (pI) of the protein, at a concentration of approximately 0.5 mg mL-1. Comparisons of the kinetic and thermodynamic constants describing binding of carbonic anhydrase and vancomycin to immobilized benzenesulfonamide and N-alpha-Ac-Lys-D-Ala-D-Ala groups, respectively, on mixed SAMs (by methods described in this paper) and in the carboxymethyl dextran matrix of commercially available substrates yielded (for these systems) essentially indistinguishable values of Kd, koff, and kon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Self-citationSurface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationA Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Self-citationOptical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015
Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000) · Journal of the American Chemical Society · doi:10.1021/ja001215b · Cited by 932
Rabilloud, T. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1<3::aid-prot3>3.0.co;2-r · Cited by 717
Hydroxylated Quantum Dots as Luminescent Probes for in Situ Hybridization
Pathak, S., Choi, S.-K., Arnheim, N., & Thompson, M. E. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0058334 · Cited by 614
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Label-free screening of bio-molecular interactions
Cooper, M. A. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2111-y · Cited by 460
Diels−Alder Click Cross-Linked Hyaluronic Acid Hydrogels for Tissue Engineering
Nimmo, C. M., Owen, S. C., & Shoichet, M. S. (2011) · Biomacromolecules · doi:10.1021/bm101446k · Cited by 436
Towards advanced chemical and biological nanosensors—An overview
Yonzon, C. R., Stuart, D. A., Zhang, X., McFarland, A. D., Haynes, C. L., & Van Duyne, R. P. (2005) · Talanta · doi:10.1016/j.talanta.2005.06.039 · Cited by 379
Wijaya, E., Lenaerts, C., Maricot, S., Hastanin, J., Habraken, S., Vilcot, J.-P., Boukherroub, R., & Szunerits, S. (2011) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2011.05.001 · Cited by 377
Sam, S., Touahir, L., Salvador Andresa, J., Allongue, P., Chazalviel, J.-N., Gouget-Laemmel, A. C., Henry de Villeneuve, C., Moraillon, A., Ozanam, F., Gabouze, N., et al. (2010) · Langmuir · doi:10.1021/la902220a · Cited by 377
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Kalia, J., & Raines, R. (2010) · Current Organic Chemistry · doi:10.2174/138527210790069839 · Cited by 362
Haynes, C. L., Yonzon, C. R., Zhang, X., & Van Duyne, R. P. (2005) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1376 · Cited by 354
Effect of Surface Wettability on the Adhesion of Proteins
Sethuraman, A., Han, M., Kane, R. S., & Belfort, G. (2004) · Langmuir · doi:10.1021/la049454q · Cited by 344
Ciampi, S., Harper, J. B., & Gooding, J. J. (2010) · Chemical Society Reviews · doi:10.1039/b923890p · Cited by 310
A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7
Subramanian, A., Irudayaraj, J., & Ryan, T. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.007 · Cited by 281
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Adsorption of Proteins to Hydrophobic Sites on Mixed Self-Assembled Monolayers
Ostuni, E., Grzybowski, B. A., Mrksich, M., Roberts, C. S., & Whitesides, G. M. (2003) · Langmuir · doi:10.1021/la020649c · Cited by 261
Self-citationChapman, R. G., Ostuni, E., Yan, L., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la991579l · Cited by 254
Self-citationHuang, W., Besar, K., LeCover, R., Dulloor, P., Sinha, J., Martínez Hardigree, J. F., Pick, C., Swavola, J., Everett, A. D., Frechette, J., et al. (2014) · Chem. Sci. · doi:10.1039/c3sc52638k · Cited by 83
Asymmetric amyloid fibril elongation: a new perspective on a symmetric world
Heldt, C. L., Zhang, S., & Belfort, G. (2011) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.22861 · Cited by 30
Metadata
- Authors
- Lahiri, J., Isaacs, L., Tien, J., & Whitesides, G. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-01-08
- Volume
- 71
- Issue
- 4
- Pages
- 777-790
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047917567
- Cited by
- 601
- References
- 1
- FWCI
- 21.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.