The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Quantitative Analysis of Molecular Interaction in a Microfluidic Channel: The T-Sensor
Abstract
The T-sensor is a recently developed microfluidic chemical measurement device that exploits the low Reynolds number flow conditions in microfabricated channels. The interdiffusion and resulting chemical interaction of components from two or more input fluid streams can be monitored optically, allowing measurement of analyte concentrations on a continuous basis. In a simple form of T-sensor, the concentration of a target analyte is determined by measuring fluorescence intensity in a region where the analyte and a fluorescent indicator have interdiffused. An analytical model has been developed that predicts device behavior from the diffusion coefficients of the analyte, indicator, and analyte--indicator complex and from the kinetics of the complex formation. Diffusion coefficients depend on the local viscosity which, in turn, depends on local concentrations of all analytes. These relationships, as well as reaction equilibria, are often unknown. A rapid method for determining these unknown parameters by interpreting T-sensor experiments through the model is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perry, J. H. (1950) · Journal of Chemical Education · doi:10.1021/ed027p533.1 · Cited by 3,807
Investigations on the Theory of the Brownian Movement
Topping, J. (1956) · Physics Bulletin · doi:10.1088/0031-9112/7/10/012 · Cited by 2,033
Curry, S., Mandelkow, H., Brick, P., & Franks, N. (1998) · Nature Structural Biology · doi:10.1038/1869 · Cited by 1,377
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Self-citationDiffusion-based extraction in a microfabricated device
Brody, J. P., & Yager, P. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)80219-1 · Cited by 278
Self-citationTemperature Behaviour of Human Serum Albumin
WETZEL, R., BECKER, M., BEHLKE, J., BILLWITZ, H., BoHM, S., EBERT, B., HAMANN, H., KRUMBIEGEL, J., & LASSMANN, G. (1980) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1980.tb04449.x · Cited by 248
Albumin Blue 580 Fluorescence Assay for Albumin
Kessler, M. A., Meinitzer, A., & Wolfbeis, O. S. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2113 · Cited by 86
Protein diffusion coefficient measurements by laminar flow analysis: Method and applications
Walters, R. R., Graham, J. F., Moore, R. M., & Anderson, D. J. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90152-0 · Cited by 84
Cited by
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Self-citationTokeshi, M., Minagawa, T., Uchiyama, K., Hibara, A., Sato, K., Hisamoto, H., & Kitamori, T. (2002) · Analytical Chemistry · doi:10.1021/ac011111z · Cited by 342
Metadata
- Authors
- Kamholz, A. E., Weigl, B. H., Finlayson, B. A., & Yager, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-28
- Volume
- 71
- Issue
- 23
- Pages
- 5340-5347
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2022069856
- Cited by
- 631
- References
- 10
- FWCI
- 21.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.