The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Secondary Electrospray Ionization Ion Mobility Spectrometry/Mass Spectrometry of Illicit Drugs
Abstract
A secondary electrospray ionization (SESI) method was developed as a nonradioactive ionization source for ion mobility spectrometry (IMS). This SESI method relied on the gas-phase interaction between charged particles created by electrospray ionization (ESI) and neutral gaseous sample molecules. Mass spectrometry (MS) was used as the detection method after ion mobility separation for ion identification. Preliminary investigations focussed on understanding the ionization process of SESI. The performance of ESI-IMS and SESI-IMS for illicit drug detection was evaluated by determining the analytical figures of merit. In general, SESI had a higher ionization efficiency for small volatile molecules compared with the electrospray method. The potential of developing a universal interface for both GC- and LC-MS with an addition stage of mobility separation was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hill, H. H., Siems, W. F., & St. Louis, R. H. (1990) · Analytical Chemistry · doi:10.1021/ac00222a001 · Cited by 737
Self-citationIon formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
Gas-Phase Conformation of Biological Molecules: Bradykinin
Wyttenbach, T., von Helden, G., & Bowers, M. T. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9535928 · Cited by 384
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Electrospray Ionization Ion Mobility Spectrometry
Wittmer, D., Chen, Y. H., Luckenbill, B. K., & Hill, H. H. (1994) · Analytical Chemistry · doi:10.1021/ac00086a021 · Cited by 216
Self-citationOxidation of peptides during electrospray ionization
Morand, K. L., Talbo, G. H., & Mann, M. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070811 · Cited by 127
Biochemical and Biotechnological Applications of Electrospray Ionization Mass Spectrometry
Snyder, A. P. (1996) · ACS symposium series · doi:10.1021/bk-1995-0619 · Cited by 121
Plasma chromatography of heroin and cocaine with mass-identified mobility spectra
Karasek, F. W., Hill, H. H., & Kim, S. H. (1976) · Journal of Chromatography A · doi:10.1016/0021-9673(76)80009-x · Cited by 79
Self-citation
Cited by
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Metadata
- Authors
- Wu, C., Siems, W. F., & Hill, H. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-11
- Volume
- 72
- Issue
- 2
- Pages
- 396-403
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1969724828
- Cited by
- 278
- References
- 11
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.