The DOI matches its Crossref record.
Oriented Immobilization of Antibodies onto the Gold Surfaces via Their Native Thiol Groups
Abstract
The general approach for site-oriented immobilization of antibodies onto gold supports is reported. The immobilization is carried out using the native sulfide groups of immunoglobulin (IgG). To liberate the thiol groups, the intact IgG was split into two half-IgG fragments without destruction of the binding site of the antibody. The immobilization of half-IgG fragments on the gold surface was carried out by simple adsorption. The antigen binding capacity of the half-IgG modified gold supports is similar to that of the gold surfaces with the traditionally linked antibodies and is much higher than for nonspecifically adsorbed intact IgGs. The immobilized antibodies, according to the proposed approach, maintain high antigen binding constants. The immobilization procedure provides orientation of IgG fragments in terms of the similar distance between the binding site of the antibody and the surface of the gold support, which does not cause the distribution of the apparent affinity constants. The high operational stability of half-IgG modified gold electrodes makes them applicable for analytical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathogen detection: A perspective of traditional methods and biosensors
Lazcka, O., Campo, F. J. D., & Muñoz, F. X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.036 · Cited by 1,500
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017) · Biointerphases · doi:10.1116/1.4978435 · Cited by 414
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Solid supports for microarray immunoassays
Kusnezow, W., & Hoheisel, J. D. (2003) · Journal of Molecular Recognition · doi:10.1002/jmr.625 · Cited by 277
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Urbán, P., Estelrich, J., Cortés, A., & Fernàndez-Busquets, X. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.001 · Cited by 90
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Metadata
- Authors
- Karyakin, A. A., Presnova, G. V., Rubtsova, M. Y., & Egorov, A. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-07-21
- Volume
- 72
- Issue
- 16
- Pages
- 3805-3811
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965080527
- Cited by
- 206
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.