The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Velocity-Difference Induced Focusing of Nucleotides in Capillary Electrophoresis with a Dynamic pH Junction
Abstract
Velocity-difference induced focusing (V-DIF) of nucleotides was achieved by using a dynamic pH junction in capillary electrophoresis (CE) with UV detection. The influence of specific analyte properties, such as nucleotide base structure, sugar structure, and degree of phosphorylation, is examined. The pKa values and borate complexation with vicinal diols are important factors that caused the focusing. Therefore, the pH and borate content in the sample and background electrolyte can be adjusted to optimize the focusing effect. This method allows the injection of large volumes of sample (approximately 300 nL), resulting in at least 50-fold improvement in concentration sensitivity. The detection limit of 4.0 x 10(-8) M for nucleotides can be achieved in favorable conditions. V-DIF can be also applied to nucleotide pool analysis from cell extracts to improve the concentration sensitivity of CE and to reduce the time-consuming steps of desalting and off-line preconcentration that are often required for assays of nucleotides from biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased Vascularization in Mice Overexpressing Angiopoietin-1
Suri, C., McClain, J., Thurston, G., McDonald, D. M., Zhou, H., Oldmixon, E. H., Sato, T. N., & Yancopoulos, G. D. (1998) · Science · doi:10.1126/science.282.5388.468 · Cited by 818
Cited by
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Wang, C., Li, C., Zang, X., Han, D., Liu, Z., & Wang, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.027 · Cited by 56
Zhang, Z., Sun, L., Zhu, G., Yan, X., & Dovichi, N. J. (2015) · Talanta · doi:10.1016/j.talanta.2015.01.040 · Cited by 53
Zhang, Z., Hebert, A. S., Westphall, M. S., Qu, Y., Coon, J. J., & Dovichi, N. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02991 · Cited by 30
Metadata
- Authors
- Britz-McKibbin, P., Bebault, G. M., & Chen, D. D. Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-03-11
- Volume
- 72
- Issue
- 8
- Pages
- 1729-1735
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1999741750
- Cited by
- 201
- References
- 1
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.