Improving the Thromboresistivity of Chemical Sensors via Nitric Oxide Release: Fabrication and in Vivo Evaluation of NO-Releasing Oxygen-Sensing Catheters
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The development and in vivo analytical performance of a nitric oxide (NO)-releasing amperometric oxygen sensor with greatly enhanced thromboresistivity are reported. Gas permeable coatings formulated with cross-linked silicone rubber (SR) containing NO-generating compounds (diazeniumdiolates) are shown to release NO for extended periods of time (> 20 h) while reducing platelet adhesion and activation. Oxygen-sensing catheters prepared by dip-coating the NO-releasing films over the outer SR tubes of the implantable devices display similar analytical response properties in vitro (sensitivity, selectivity, response times) when compared to analogous sensors prepared without the NO release coatings. Superior analytical accuracy (relative to blood PO2 values measured in vitro) and greatly reduced thrombus formation on the outer surface of the sensors are observed in vivo (in canine model) with the NO release PO2 sensors compared to control sensors (without NO release) implanted simultaneously within the same animals. Based on these preliminary studies, the use of NO release polymers to fabricate catheter-style chemical sensors may be a potential solution to lingering biocompatibility and concomitant performance problems encountered when attempting to employ such devices for continuous intravascular measurements of blood gases and electrolytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ignarro, L. J., Fukuto, J. M., Griscavage, J. M., Rogers, N. E., & Byrns, R. E. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.17.8103 · Cited by 856
Catheter-type sensor for potentiometric monitoring of oxygen, pH and carbon dioxide
Meruva, R. K., & Meyerhoff, M. E. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00097-3 · Cited by 64
Self-citation
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Self-citationNitric oxide release: Part II. Therapeutic applications
Carpenter, A. W., & Schoenfisch, M. H. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15273h · Cited by 964
Self-citationBakker, E., & Telting-Diaz, M. (2002) · Analytical Chemistry · doi:10.1021/ac0202278 · Cited by 662
Recent developments in nitric oxide donor drugs
Miller, M. R., & Megson, I. L. (2007) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707224 · Cited by 628
Metadata
- Authors
- Schoenfisch, M. H., Mowery, K. A., Rader, M. V., Baliga, N., Wahr, J. A., & Meyerhoff, M. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-02-17
- Volume
- 72
- Issue
- 6
- Pages
- 1119-1126
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010064142
- Cited by
- 121
- References
- 2
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving the Thromboresistivity of Chemical Sensors via Nitric Oxide Release: Fabrication and in Vivo Evaluation of NO-Releasing Oxygen-Sensing Catheters. https://app.cochat.ai/papers/10.1021/ac991370c
- The paper
- Schoenfisch, M. H., Mowery, K. A., Rader, M. V., Baliga, N., Wahr, J. A., & Meyerhoff, M. E. (2000). Improving the Thromboresistivity of Chemical Sensors via Nitric Oxide Release: Fabrication and in Vivo Evaluation of NO-Releasing Oxygen-Sensing Catheters. Analytical Chemistry. https://doi.org/10.1021/ac991370c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.