Contactless Photoelectrochemical Biosensor Based on the Ultraviolet–Assisted Gas Sensing Interface of Three-Dimensional SnS2 Nanosheets: From Mechanism Reveal to Practical Application
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This work reports a contactless photoelectrochemical biosensor based on an ultraviolet-assisted gas sensor (UV–AGS) with a homemade three-dimensional (3D)-SnS 2 nanosheet-functionalized interdigitated electrode. After rigorous examination, it was found that the gas responsiveness accelerated and the sensitivity increased using the UV irradiation strategy. The effects of the interlayer structure and the Schottky heterojunction on the gas-sensitive response of O 2 and NH 3 under UV irradiation were further investigated theoretically by 3D electrostatic field simulations and first-principles density functional theory to reveal the mechanism. Finally, a UV–AGS device was developed to quantify the blood ammonia bioassay in a small-volume whole blood sample by alkalizing blood to release gas-phase ammonia with a linear range of 25–5000 μM with a limit of detection (LOD) of 29.5 μM. The device also enables a rapid immunoassay of human cardiac troponin I (cTnI) with a linear range of 0.4–25.6 ng/mL and an LOD of 0.37 ng/mL using a urease-labeled antibody as the immune recognition molecule. Both analyses showed satisfying specificity and stability, suggesting that the device can be applied to practical assays and is of great potential to increase the value of gas-sensitive sensors in chemical biosensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single- and multi-wall carbon nanotube field-effect transistors
Martel, R., Schmidt, T., Shea, H. R., Hertel, T., & Avouris, P. (1998) · Applied Physics Letters · doi:10.1063/1.122477 · Cited by 2,812
Shu, J., & Tang, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04199 · Cited by 976
Self-citationYang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
High Performance and Bendable Few-Layered InSe Photodetectors with Broad Spectral Response
Tamalampudi, S. R., Lu, Y.-Y., U., R. K., Sankar, R., Liao, C.-D., B., K. M., Cheng, C.-H., Chou, F. C., & Chen, Y.-T. (2014) · Nano Letters · doi:10.1021/nl500817g · Cited by 811
Recent advances in energy-saving chemiresistive gas sensors: A review
Majhi, S. M., Mirzaei, A., Kim, H. W., Kim, S. S., & Kim, T. W. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105369 · Cited by 653
Huang, Y., Sutter, E., Sadowski, J. T., Cotlet, M., Monti, O. L. A., Racke, D. A., Neupane, M. R., Wickramaratne, D., Lake, R. K., Parkinson, B. A., et al. (2014) · ACS Nano · doi:10.1021/nn504481r · Cited by 551
Thermochemical description of dielectric breakdown in high dielectric constant materials
McPherson, J., Kim, J.-Y., Shanware, A., & Mogul, H. (2003) · Applied Physics Letters · doi:10.1063/1.1565180 · Cited by 398
Large‐Size Growth of Ultrathin SnS2 Nanosheets and High Performance for Phototransistors
Zhou, X., Zhang, Q., Gan, L., Li, H., & Zhai, T. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201600318 · Cited by 361
Zeng, R., Lian, K., Su, B., Lu, L., Lin, J., Tang, D., Lin, S., & Wang, X. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202110670 · Cited by 340
Self-citationElectronic Processes on Semiconductor Surfaces during Chemisorption
Wolkenstein, T. (1991) · Springer eBooks · doi:10.1007/978-1-4615-3656-7 · Cited by 281
Cited by
CRISPR-Driven Biosensors: A New Frontier in Rapid and Accurate Disease Detection
Razavi, Z., Soltani, M., Souri, M., & Pazoki-Toroudi, H. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2024.2400267 · Cited by 45
Metadata
- Authors
- Huang, L., Cai, G., Zeng, R., Yu, Z., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-06-23
- Volume
- 94
- Issue
- 26
- Pages
- 9487-9495
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4283323342
- Cited by
- 171
- References
- 27
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.