Cited by 35Mass Spectrometry Techniques and ApplicationsMicrofluidic and Capillary Electrophoresis ApplicationsAdvanced Proteomics Techniques and Applications

Utilizing Microchip Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry

Open access
Black, William A., Stocks, Bradley B., Mellors, J. Scott, Engen, John R., Ramsey, J. Michael·2015·Analytical Chemistry

Abstract

Hydrogen exchange (HX) mass spectrometry (MS) of complex mixtures requires a fast, reproducible, and high peak capacity separation prior to MS detection. The current paradigm relies on liquid chromatography (LC) with fast gradients performed at low temperatures to minimize back exchange. Unfortunately, under these conditions, the efficiency of LC is limited due to resistance to mass transfer, reducing the capability to analyze complex samples. Capillary electrophoresis (CE), on the other hand, is not limited by resistance to mass transfer, enabling very rapid separations that are not adversely affected by low temperature. Previously, we have demonstrated an integrated microfluidic device coupling CE with electrospray ionization (ESI) capable of very rapid and high efficiency separations. In this work, we demonstrate the utility of this microchip CE-ESI device for HX MS. High speed CE-ESI of a bovine hemoglobin pepsin digestion was performed in 1 min with a peak capacity of 62 versus a similar LC separation performed in 7 min with peak capacity of 31. A room temperature CE method performed in 1.25 min provided similar deuterium retention as an 8.5 min LC method conducted at 0 °C. Separation of a complex mixture with CE was done with considerably better speed and nearly triple the peak capacity than the equivalent separation by LC. Overall, the results indicate the potential utility of microchip CE-ESI for HX MS.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b01179

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Microchip CE-MS analysis of a bovine hemoglobin pepsin digest demonstrated high peak capacity and speed compared to conventional LC separation of the same sample.

    “For instance, microchip CE-MS analysis of a bovine hemoglobin pepsin digest has demonstrated high peak capacity and speed when compared to a conventional LC separation of the same sample136.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [15]Landers JP Handbook of capillary electrophoresis 1997 894 CRC Press Boca Raton 2nd ed.
  2. [16]Nelson RJ Paulus A Cohen AS Guttman A Karger BL J Chromatogr 1989 480 111 127

Cited by

Sorted by citations

Authors
Black, W. A., Stocks, B. B., Mellors, J. S., Engen, J. R., & Ramsey, J. M.
Affiliations
  • University of North Carolina at Chapel Hill (US)
  • Northeastern University (US)
Corresponding author
Ramsey, J. Michael
Venue
Analytical Chemistry
Published
2015-06-02
Volume
87
Issue
12
Pages
6280-6287
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W281344288
Cited by
35
References
37
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 2
FWCI
2.53
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
  • UNC Libraries
Funders
  • Northeastern University
  • Center for Biomedical Microdevices, University of North Carolina, Chapel Hill
  • National Institute of General Medical Sciences (R01-GM101135)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
hydrogen-deuterium exchange mass spectrometry, capillary electrophoresis, electrospray ionization, microfluidics, peak capacity, separation speed, deuterium retention, bovine hemoglobin, pepsin digestion
MeSH terms
Animals, Cattle, Chromatography, High Pressure Liquid, Hemoglobins, Mass Spectrometry, Deuterium Exchange Measurement, Electrophoresis, Microchip

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review