Abstract
Monte Carlo simulations are used to examine the bias and loss of precision that result from experimental error and analysis procedures in real-time quantitative polymerase chain reaction (PCR). In the limit of small copy numbers (N0), Poisson statistics govern the dispersion in estimates of the quantification cycle (Cq) for replicate experiments, permitting the estimation of N0 from the Cq variance, which is inversely proportional to N0. We derive corrections to expressions given previously for this determination. With increasing N0, the Poisson contribution decreases and other effects, like pipet volume uncertainty (typically >3%), dominate. Cycle-to-cycle variability in the amplification efficiency E produces scale dispersion similar to that for variability in the sensitivity of fluorescence detection. When this E variability is proportional to just the amplification (E - 1), there is insignificant effect on Cq if scale-independent definitions are used for this marker. Single-reaction analysis methods based on the exponential growth equation are inherently low-biased in E and high-biased in N0, and these biases can amount to factor-of-4 or greater error in N0. For estimating Cq, their greatest limitation is use of a constant absolute threshold, making them inefficient for data that exhibit scale variability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
A standard curve based method for relative real time PCR data processing
Larionov, A., Krause, A., & Miller, W. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-62 · Cited by 946
Mathematics of quantitative kinetic PCR and the application of standard curves
Rutledge, R. G. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng093 · Cited by 545
Liu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516
Standardized determination of real-time PCR efficiency from a single reaction set-up
Tichopad, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng122 · Cited by 455
Research works printed but not linked: 4
- Morrison T. B., 1998, BioTechniques, 24, 954
- 10.2144/3702a0246 · doi:10.2144/3702a0246
- Press W. H., 1986, Numerical Recipes
- Curry J. D., 2002, Mol. Biol. Today, 3, 79
Cited by
Taylor, S. C., Laperriere, G., & Germain, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-02217-x · Cited by 638
“(1) Always begin a study by testing each primer pair in a 1/10 diluted, pooled cDNA or gDNA sample (using individual samples from each treatment group in the study set) in duplicate with qPCR under optimized thermocycling conditions and a no template control for each target.”
BackgroundForootan, A., Sjöback, R., Björkman, J., Sjögreen, B., Linz, L., & Kubista, M. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.04.001 · Cited by 578
“Although other factors also contribute to variation across replicates [14], sampling noise, which can be modeled by the Poisson distribution, is expected to dominate at very low copy numbers [15,16].”
BackgroundAdvances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
Cao, L., Cui, X., Hu, J., Li, Z., Choi, J. R., Yang, Q., Lin, M., Ying Hui, L., & Xu, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.082 · Cited by 291
“…detection, it is unable to provide absolute result (exact quantity of target), due to the issue of amplification bias that comes from fluorescence baseline estimation errors and polymerase's preference on amplification efficiency in qPCR (Ruijter et al., 2009; Tellinghuisen and Spiess, 2015b).”
BackgroundEstrogen receptor profiles across tissues from male and female Rattus norvegicus
Hutson, D. D., Gurrala, R., Ogola, B. O., Zimmerman, M. A., Mostany, R., Satou, R., & Lindsey, S. H. (2019) · Biology of Sex Differences · doi:10.1186/s13293-019-0219-9 · Cited by 152
Deligezer, U., Bronkhorst, A. J., & Holdenrieder, S. (2022) · Diagnostics · doi:10.3390/diagnostics12123042 · Cited by 48
Metadata
- Authors
- Tellinghuisen, J., & Spiess, A.-N.
- Affiliations
- Vanderbilt University (US)
- University Medical Center Hamburg-Eppendorf (DE)
- Corresponding author
- Tellinghuisen, Joel
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-08-13
- Volume
- 87
- Issue
- 17
- Pages
- 8925-8931
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2412182458
- Cited by
- 35
- References
- 36
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 5 · 2020: 6 · 2019: 2 · 2017: 5 · 2016: 5 · 2015: 1
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Deutsche Forschungsgemeinschaft (Sp721/4-1)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- real-time quantitative PCR, Poisson statistics, fluorescence detection sensitivity, exponential growth model, absolute threshold, Monte Carlo simulation, bias and precision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.