Abstract
Characterization of biopharmaceutical products is a challenging task, which needs to be carried out at several different levels (including both primary structure and conformation). An additional difficulty frequently arises due to the structural heterogeneity inherent to many protein-based therapeutics (e.g., extensive glycosylation or "designer" modifications such as chemical conjugation) or introduced postproduction as a result of stress (e.g., oxidation and deamidation). A combination of ion-exchange chromatography (IXC) with online detection by native electrospray ionization mass spectrometry (ESI MS) allows characterization of complex and heterogeneous therapeutic proteins and protein conjugates to be accomplished at a variety of levels without compromising their conformational integrity. The IXC/ESI MS measurements allow protein conjugates to be profiled by analyzing conjugation stoichiometry and the presence of multiple positional isomers, as well as to establish the effect of chemical modifications on the conformational integrity of each species. While mass profiling alone is not sufficient for identification of nonenzymatic post-translational modifications (PTMs) that result in a very small mass change of the eluting species (e.g., deamidation), this task can be completed using online top-down structural analysis, as demonstrated using stressed interferon-β as an example. The wealth of information that can be provided by IXC/native ESI MS and tandem mass spectrometry (MS/MS) on protein-based therapeutics will undoubtedly make it a very valuable addition to the experimental toolbox of biopharmaceutical analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Similarly, ion-exchange chromatography (IEX)-MS has been used to characterize protein conjugates [78,79].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [78]
In the citing paper
“In recent years, important progress in native purification methods such as native gel-eluted liquid fraction entrapment electrophoresis (GeLFrEE) separation,36 native gel electrophoresis,37 ion exchange chromatography (IEX),38 hydrophobic interaction chromatography (HIC),39,40 and online buffer exchange, has made these methods more applicable for complex mixtures and for characterisation of endo”
From Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry (2020) · cites this paper as [38]
Citations
Cites
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Fragmentation pathways of protonated peptides
Paizs, B., & Suhai, S. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20024 · Cited by 1,118
Biopharmaceutical benchmarks 2014
Walsh, G. (2014) · Nature Biotechnology · doi:10.1038/nbt.3040 · Cited by 1,008
The folding of hen lysozyme involves partially structured intermediates and multiple pathways
Radford, S. E., Dobson, C. M., & Evans, P. A. (1992) · Nature · doi:10.1038/358302a0 · Cited by 708
Sinz, A. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20082 · Cited by 648
Post-translational Modifications Differentially Affect IgG1 Conformation and Receptor Binding
Houde, D., Peng, Y., Berkowitz, S. A., & Engen, J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900540-mcp200 · Cited by 393
Electron-capture dissociation tandem mass spectrometry
Zubarev, R. A. (2004) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2003.12.002 · Cited by 360
Theory and practice of size exclusion chromatography for the analysis of protein aggregates
Fekete, S., Beck, A., Veuthey, J.-L., & Guillarme, D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.011 · Cited by 324
Runkel, L., Meier, W., Pepinsky, R. B., Karpusas, M., Whitty, A., Kimball, K., Brickelmaier, M., Muldowney, C., Jones, W., & Goelz, S. E. (1998) · Pharmaceutical Research · doi:10.1023/a:1011974512425 · Cited by 304
Wakankar, A. A., & Borchardt, R. T. (2006) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20740 · Cited by 254
Research works printed but not linked: 2
- Lin, L.InSymposium on the Characterization of Biotechnology Pharmaceutical Products;Brown, F.; Lubiniecki, A.; Murano, G., Eds.Karger:Washington, DC, 1995; pp97–104.
- Robinson N. E., 2004, Molecular Clocks: Deamidation of Asparaginyl and Glutaminyl Residues in Peptides and Proteins
Cited by
Liu, X. R., Zhang, M. M., & Gross, M. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00815 · Cited by 242
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Novel Strategies to Address the Challenges in Top-Down Proteomics
Melby, J. A., Roberts, D. S., Larson, E. J., Brown, K. A., Bayne, E. F., Jin, S., & Ge, Y. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00099 · Cited by 190
The Role of Electron Transfer Dissociation in Modern Proteomics
Riley, N. M., & Coon, J. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04810 · Cited by 180
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
“Similarly, ion-exchange chromatography (IEX)-MS has been used to characterize protein conjugates [78,79].”
MethodRoberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Cai, W., Tucholski, T., Chen, B., Alpert, A. J., McIlwain, S., Kohmoto, T., Jin, S., & Ge, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00380 · Cited by 135
Füssl, F., Cook, K., Scheffler, K., Farrell, A., Mittermayr, S., & Bones, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05241 · Cited by 132
Leblanc, Y., Ramon, C., Bihoreau, N., & Chevreux, G. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.02.017 · Cited by 127
Online Hydrophobic Interaction Chromatography–Mass Spectrometry for Top-Down Proteomics
Chen, B., Peng, Y., Valeja, S. G., Xiu, L., Alpert, A. J., & Ge, Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04285 · Cited by 110
Yan, Y., Liu, A. P., Wang, S., Daly, T. J., & Li, N. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03773 · Cited by 110
Top-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
“In addition to HIC, recent work using online IEC coupled with MS also demonstrated great success in the study of native proteins and protein complexes [47].”
Bailey, A. O., Han, G., Phung, W., Gazis, P., Sutton, J. N., Josephs, J. L., & Sandoval, W. N. (2018) · mAbs · doi:10.1080/19420862.2018.1521131 · Cited by 113
“Recent reports have shown that native IEC-MS is possible to implement, but these demonstrations required high concentrations of ammonium acetate (>200 mM) to elute proteins, which can result in reduced sensitivity of the mass spectra.(16,21) Low sensitivity and lack of robustness remain significant barriers to any pot…”
BackgroundBelov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
“All capillary electrophoresis equipment, including bare fused silica (BFS) and neutral polyacrylamide-coated capillaries with hydrofluoric acid-etched emitters for sheathless nanoESI (aka CESI), were provided by SCIEX Separations (Brea, CA, USA).”
InfluentialFüssl, F., Trappe, A., Cook, K., Scheffler, K., FitzGerald, O., & Bones, J. (2018) · mAbs · doi:10.1080/19420862.2018.1531664 · Cited by 106
Beck, A., D’Atri, V., Ehkirch, A., Fekete, S., Hernandez‐Alba, O., Gahoual, R., Leize‐Wagner, E., François, Y., Guillarme, D., & Cianférani, S. (2019) · Expert Review of Proteomics · doi:10.1080/14789450.2019.1578215 · Cited by 97
Capillary zone electrophoresis-mass spectrometry for top-down proteomics
Shen, X., Yang, Z., McCool, E. N., Lubeckyj, R. A., Chen, D., & Sun, L. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115644 · Cited by 92
“SEC, IEX and CZE separations have been online coupled to native-ESI-MS for analysis of simple protein complex samples [22,50,96,97].”
MethodBelov, A. M., Zang, L., Sebastiano, R., Santos, M. R., Bush, D. R., Karger, B. L., & Ivanov, A. R. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800067 · Cited by 88
Shen, X., Kou, Q., Guo, R., Yang, Z., Chen, D., Liu, X., Hong, H., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02725 · Cited by 78
Top-down proteomics: Where we are, where we are going?
Fornelli, L., Toby, T. K., Schachner, L. F., Doubleday, P. F., Srzentić, K., DeHart, C. J., & Kelleher, N. L. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2017.02.002 · Cited by 77
“[13] Alternatively to its complementary role in structural biology,[14,15] the high-MW capabilities of native top-down might someday be employed on-line with the appropriate protein separation techniques such as ion exchange chromatography, potentially increasing the analysis throughput and steering native topdown tow…”
MethodHaverland, N. A., Skinner, O. S., Fellers, R. T., Tariq, A. A., Early, B. P., LeDuc, R. D., Fornelli, L., Compton, P. D., & Kelleher, N. L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1635-x · Cited by 62
Studying protein structure and function by native separation–mass spectrometry
van Schaick, G., Haselberg, R., Somsen, G. W., Wuhrer, M., & Domínguez‐Vega, E. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00353-7 · Cited by 71
Schwenzer, A., Kruse, L., Jooß, K., & Neusüß, C. (2023) · PROTEOMICS · doi:10.1002/pmic.202300135 · Cited by 63
“Chromatographic separation approaches compatible with native conditions include SEC [13–15], ion-exchange chromatography [16], hydrophobic interaction chromatography [17, 18], and affinity chromatography [19].”
MethodWei, B., Han, G., Tang, J., Sandoval, W. N., & Zhang, Y. T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04467 · Cited by 60
Versatile, Sensitive, and Robust Native LC–MS Platform for Intact Mass Analysis of Protein Drugs
Yan, Y., Xing, T., Wang, S., & Li, N. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00277 · Cited by 61
Cammarata, M., Thyer, R., Lombardo, M., Anderson, A., Wright, D., Ellington, A., & Brodbelt, J. S. (2017) · Chemical Science · doi:10.1039/c6sc05235e · Cited by 56
Yan, Y., Xing, T., Wang, S., Daly, T. J., & Li, N. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113313 · Cited by 58
Mehaffey, M. R., Xia, Q., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03784 · Cited by 53
Capillary HILIC-MS: A New Tool for Sensitive Top-Down Proteomics
Gargano, A. F. G., Roca, L. S., Fellers, R. T., Bocxe, M., Domínguez-Vega, E., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00382 · Cited by 52
Xu, T., Han, L., & Sun, L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00975 · Cited by 53
Shi, L., Xiao, G., Dillon, T. M., Ricci, M. S., & Bondarenko, P. V. (2020) · mAbs · doi:10.1080/19420862.2020.1739825 · Cited by 56
“Characterization of digested mAbs and proteins with molecular weights below ~30 kDa has also been described by utilizing an ammonium formate and ammonium acetate-based pH and salt gradient.(29,33) Yan et al.”
MethodIt is time for top-down venomics
Melani, R. D., Nogueira, F. C. S., & Domont, G. B. (2017) · The Journal of venomous animals and toxins including tropical diseases · doi:10.1186/s40409-017-0135-6 · Cited by 49
“[75] coupled ion exchange chromatography on-line with native MS, potentially increasing the analysis throughput of unknown intact protein conjugates.”
BackgroundMurisier, A., Duivelshof, B. L., Fekete, S., Bourquin, J., Schmudlach, A., Lauber, M. A., Nguyen, J. M., Beck, A., Guillarme, D., & D’Atri, V. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462499 · Cited by 50
Jooß, K., Schachner, L. F., Watson, R., Gillespie, Z. B., Howard, S. A., Cheek, M. A., Meiners, M. J., Sobh, A., Licht, J. D., Keogh, M., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04975 · Cited by 44
Intact protein bioanalysis by liquid chromatography – High-resolution mass spectrometry
Bults, P., Spanov, B., Olaleye, O., van de Merbel, N. C., & Bischoff, R. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.01.032 · Cited by 45
Jin, Y., Yi, Y., & Yeung, B. (2020) · Methods · doi:10.1016/j.ymeth.2020.08.002 · Cited by 50
Standard procedures for native CZE‐MS of proteins and protein complexes up to 800 kDa
Jooß, K., McGee, J. P., Melani, R. D., & Kelleher, N. L. (2021) · Electrophoresis · doi:10.1002/elps.202000317 · Cited by 43
Tong, W., & Wang, G. (2018) · Methods · doi:10.1016/j.ymeth.2018.04.025 · Cited by 40
Muneeruddin, K., Bobst, C. E., Frenkel, R., Houde, D., Turyan, I., Sosic, Z., & Kaltashov, I. A. (2017) · The Analyst · doi:10.1039/c6an02041k · Cited by 38
Self-citationLeblanc, Y., Bihoreau, N., & Chevreux, G. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.07.014 · Cited by 44
Direct Tissue Profiling of Protein Complexes: Toward Native Mass Spectrometry Imaging
Griffiths, R. L., & Cooper, H. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03993 · Cited by 43
Ma, F., Raoufi, F., Bailly, M. A., Fayadat‐Dilman, L., & Tomazela, D. M. (2020) · mAbs · doi:10.1080/19420862.2020.1763762 · Cited by 40
“successfully demonstrated the use of a salt gradient with increasing concentrations of ammonium acetate to characterize stressed interferon-β and pegylated proteins.(14,15) Talebi et al.”
Füssl, F., Criscuolo, A., Cook, K., Scheffler, K., & Bones, J. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00375 · Cited by 39
Leblanc, Y., Faid, V., Lauber, M. A., Wang, Q., Bihoreau, N., & Chevreux, G. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.121814 · Cited by 38
Recent progress in the analysis of protein deamidation using mass spectrometry
Ying, Y., & Li, H. (2020) · Methods · doi:10.1016/j.ymeth.2020.06.009 · Cited by 42
Wang, Y., & Olesik, S. V. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03970 · Cited by 35
A perspective view of top‐down proteomics in snake venom research
Ghezellou, P., Garikapati, V., Kazemi, S. M., Strupat, K., Ghassempour, A., & Spengler, B. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8255 · Cited by 38
Zhao, Y., Abzalimov, R. R., & Kaltashov, I. A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03792 · Cited by 31
Self-citationNative Proteomics by Capillary Zone Electrophoresis‐Mass Spectrometry
Wang, Q., Wang, Q., Qi, Z., Moeller, W. J., Wysocki, V. H., & Sun, L. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202408370 · Cited by 34
Goswami, D., Zhang, J., Bondarenko, P. V., & Zhang, Z. (2018) · Methods · doi:10.1016/j.ymeth.2018.04.011 · Cited by 26
Ventouri, I. K., Veelders, S., Passamonti, M., Endres, P., Roemling, R., Schoenmakers, P. J., Somsen, G. W., Haselberg, R., & Gargano, A. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341324 · Cited by 28
Kaltashov, I. A., Ivanov, D. G., & Yang, Y. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21829 · Cited by 30
Self-citationMillán‐Martín, S., Carillo, S., Füssl, F., Sutton, J. N., Gazis, P., Cook, K., Scheffler, K., & Bones, J. (2020) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.11.006 · Cited by 24
Kaltashov, I. A., Pawlowski, J. W., Yang, W., Muneeruddin, K., Yao, H., Bobst, C. E., & Lipatnikov, A. N. (2018) · Methods · doi:10.1016/j.ymeth.2018.04.019 · Cited by 23
Self-citationSankaran, P. K., Kabadi, P. G., Honnappa, C. G., Subbarao, M., Pai, H. V., Adhikary, L., & Palanivelu, D. V. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.10.019 · Cited by 22
Analytical tools for the characterization of deamidation in monoclonal antibodies
Spanov, B., Govorukhina, N. I., van de Merbel, N. C., & Bischoff, R. (2021) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2021.100025 · Cited by 22
Dominguez-Vega, E., De Vijlder, T., Romijn, E. P., & Somsen, G. W. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.06.021 · Cited by 19
“Mass spectrometry (MS) has demonstrated to be a pow erful tool for the characterization of peptide and protein deamidation[2-5].”
MethodSantos, D. R. D., Soares, R. R. G., Pinto, I. F., Caneira, C. R. F., Pinto, R. M. R., Chu, V., & Conde, J. P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2917305 · Cited by 18
“Ion exchange chromatography (IEC), in particular, is one of the most used chromatographic techniques in the separation, purification and analysis of proteins [27], enzymes [28], nucleic acids [29] and antibiotics [30].”
BackgroundKobayashi, H., Okada, K., Tokuda, S., Kanao, E., Masuda, Y., Naito, T., Takaya, H., Yan, M., Kubo, T., & Otsuka, K. (2020) · Scientific Reports · doi:10.1038/s41598-020-70904-3 · Cited by 19
Chromatographic separation of peptides and proteins for characterization of proteomes
Liang, Y., Zhang, L., & Zhang, Y. (2022) · Chemical Communications · doi:10.1039/d2cc05568f · Cited by 17
van Schaick, G., Domínguez‐Vega, E., Gstöttner, C., van den Berg-Verleg, J. H., Schouten, O., Akeroyd, M., Olsthoorn, M. M. A., Wuhrer, M., Heck, A. J. R., Abello, N., et al. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00663 · Cited by 13
Blevins, M. S., Juetten, K. J., James, V. K., Butalewicz, J. P., Escobar, E. E., Lanzillotti, M. B., Sanders, J. D., Fort, K. L., & Brodbelt, J. S. (2022) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00450 · Cited by 15
Microfluidic devices for protein analysis using intact and top‐down mass spectrometry
Shao, X., Huang, Y., & Wang, G. (2022) · Open Research (University of Surrey) · doi:10.1002/viw.20220032 · Cited by 15
Kumar, S., Peruri, V., & Rathore, A. S. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00308 · Cited by 13
Biotechnology-Based Pharmaceutical Products
Deb, P. K., Al-Attraqchi, O. H. A., Stanslas, J., Al-Aboudi, A. F., Al-Attraqchi, N., & Tekade, R. K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814427-5.00005-6 · Cited by 10
Jia, M., Mozziconacci, O., Abend, A. M., Wuelfing, W. P., & Pennington, J. P. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116725 · Cited by 11
Corbett, J. R., Robinson, D. E., & Patrie, S. M. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00355 · Cited by 8
MS methods to study macromolecule-ligand interaction: Applications in drug discovery
Sirtori, F. R., Altomare, A., Carini, M., Aldini, G., & Regazzoni, L. (2018) · Methods · doi:10.1016/j.ymeth.2018.06.005 · Cited by 8
Ülkü, Ö., Atakay, M., Kohneshahri, M. Y., Uzun, C., & Salih, B. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.104467 · Cited by 8
Duivelshof, B. L., Bouvarel, T., Pirner, S., Larraillet, V., Knaupp, A., Koll, H., D’Atri, V., & Guillarme, D. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242316623 · Cited by 10
“However, directly hyphenating IEX with MS often leads to a compromised chromatographic separation due to the limited buffering capacity when only volatile salts are being used in the mobile phase [28,32,33].”
BackgroundA systematic assessment of structural heterogeneity and IgG/IgE-binding of ovalbumin
Yang, W., Tu, Z., McClements, D. J., & Kaltashov, I. A. (2021) · Food & Function · doi:10.1039/d0fo02980g · Cited by 8
Self-citationYang, W., Ivanov, D. G., & Kaltashov, I. A. (2022) · mAbs · doi:10.1080/19420862.2022.2103906 · Cited by 7
Self-citationEisert, J., Maciel, E. V. S., Dederer, V., Berwanger, A., Bailey, H., Đikić, I., Knapp, S., Empting, M., Mathea, S., Jensen, H. M., et al. (2025) · Small Methods · doi:10.1002/smtd.202500658 · Cited by 7
Nascimento, P. A., Alves, A. N., dos Santos, K. A., Veloso, C. M., Santos, L. S., Fontan, R. D. C. I., Sampaio, V. S., & Bonomo, R. C. F. (2021) · Brazilian Journal of Chemical Engineering · doi:10.1007/s43153-021-00154-x · Cited by 6
Xu, S., & Kaltashov, I. A. (2017) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.7b00410 · Cited by 5
Self-citationSeparation techniques for intact antibody analysis by mass spectrometry
Schneck, N. A., Khatri, K., Maust, M. D., Jennings, M. E., Peltier, J., & Kellie, J. F. (2022) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2023.2199328 · Cited by 4
“Initial works with mAb IEC demonstrated that complications in buffer systems and the ESI process must be overcome for sufficient information from the analysis.([45]) Muneeruddin et al.”
BackgroundBiophysical Analysis of Therapeutic Antibodies in the Early Development Pipeline
Willis, L. F., Kapur, N., Radford, S. E., & Brockwell, D. J. (2024) · Biologics · doi:10.2147/btt.s486345 · Cited by 8
Muneeruddin, K., Kaltashov, I. A., & Wang, G. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-1859-2_27 · Cited by 4
Self-citationNative Proteomics by Capillary Zone Electrophoresis‐Mass Spectrometry
Wang, Q., Wang, Q., Qi, Z., Moeller, W. J., Wysocki, V. H., & Sun, L. (2024) · Angewandte Chemie · doi:10.1002/ange.202408370 · Cited by 6
Structural characterization and the role of EPR spectroscopy for protein–polymer conjugates
Giannoulis, A. (2026) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2026.115596 · Cited by 2
Leblanc, Y., Cauquil, N., Pasteau, V., Duguet, F., Bahraoui, S., André, M., & Nony, E. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c00578 · Cited by 2
Leblanc, Y., Chapuis, V., Faid, V., & Seifert, A. (2023) · Analytical Biochemistry · doi:10.1016/j.ab.2023.115088 · Cited by 3
Skjærvø, Ø., Togle, A. J., Sutton, H., Han, X., & Rauniyar, N. (2024) · Analytical Methods · doi:10.1039/d4ay00660g · Cited by 1
Chromatography (other than size-exclusion chromatography) and electrophoresis
Berkowitz, S. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-444-64173-1.00014-7 · Cited by 1
Belov (2017) · Digital Repository Service (Northeastern University) · doi:10.17760/d20259955 · Cited by 1
“The interface is sold commercially via SCIEX (Toronto, Canada) and marketed for CZE-MS applications as a part of SCIEX’s CESI platform. separation capillary with an HF-etched tip for nanoESI and a capillary used to deliver the conductive liquid.”
BackgroundMethodInfluentialRawlins (2018) · Digital Repository Service (Northeastern University) · doi:10.17760/d20292916
Pharmacokinetics and biotransformation of biopharmaceuticals
Bults, P. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.206613225
Lim, G.-M., Kim, B., & Jeong, H. (2022) · RSC Advances · doi:10.1039/d2ra00429a
Bioanalytical methodology to study the in vivo biotransformation of therapeutic proteins
Spanov, B. (2023) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.603403111
Native Mass Spectrometry in Drug Discovery and Development
Jia, M., Wen, J., Mozziconacci, O., & Pierson, E. E. (2023) · Wiley eBooks · doi:10.1002/9781119678496.ch10
Maldi-Ms2 Analyses of Insulin-Polyethylene Glycol ConjugatesPreprint
Ülkü, Ö., Atakay, M., Asiltürk, M., Uzun, C., & Salih, B. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4865030
Advanced site-specific analysis of insulin-PEG conjugates using MALDI-MS
Ülkü, Ö., Atakay, M., Asiltürk, M., Uzun, C., & Salih, B. (2025) · Essential Chem · doi:10.1080/28378083.2025.2512237
IgG Monoclonal Antibodies: Analytical Perspectives
Nirmal, D. N., & Kulkarni, S. (2025) · Applied Research · doi:10.1002/appl.70055
Advances in Proteomic Sample Preparation Strategies for Human Disease Biomarker Discovery
de Carvalho, D. T., Rosa, M. A., Pereira, M. V. D. S., de Jesus, J. R., & Figueiredo, E. C. (2026) · Separation and Purification Reviews · doi:10.1080/15422119.2026.2730200
Keeping It Native: Non‐Denaturing Approaches to Top‐Down Protein Mass Spectrometry
Xiao, M., Maciel, E. V. S., Lermyte, F., & Skinner, O. S. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70050
Metadata
- Authors
- Muneeruddin, K., Nazzaro, M., & Kaltashov, I. A.
- Affiliations
- University of Massachusetts Amherst (US)
- Corresponding author
- Kaltashov, Igor A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-09-22
- Volume
- 87
- Issue
- 19
- Pages
- 10138-10145
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2414824072
- Cited by
- 98
- References
- 45
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 7 · 2022: 11 · 2021: 9 · 2020: 13 · 2019: 11 · 2018: 17 · 2017: 12 · 2016: 3 · 2015: 2
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- United States Pharmacopeia
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Keywords
- protein conjugates, biopharmaceutical characterization, ion-exchange chromatography, regioisomers, deamidation, interferon-beta, glycosylation, chemical modification
- MeSH terms
- Animals, Chickens, Chromatography, Ion Exchange, Humans, Models, Molecular, Muramidase, Protein Conformation, Interferon-beta, Spectrometry, Mass, Electrospray Ionization, Protein Stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.