This paper presents a microfluidic device for electrical discrimination of circulating tumor cells (CTCs) using graphene nanoplates (GNPs) as a highly conductive material bound to the cell surface. For two-step cascade discrimination, the microfluidic device is composed of a CTC-enrichment device and an impedance cytometry. Using lateral magnetophoresis, the CTC-enrichment device enriches rare CTCs from millions of background blood cells. Then, the impedance cytometry electrically identifies CTCs from the enriched sample, containing CTCs and persistent residual blood cells, based on the electrical impedance of CTCs modified by the GNPs. GNPs were used as a highly conductive material for modifying surface conductivity of CTCs, thereby improving the accuracy of electrical discrimination. The experimental results showed that a colorectal cancer cell line (DLD-1) spiked into peripheral blood was enriched by nearly 500-fold by the CTC-enrichment device. The phase of the electrical signal measured from DLD-1 cells covered by GNPs shifted by about 100° in comparison with that from normal blood cells, which allows the impedance cytometry to identify CTCs at a rate of 94% from the enriched samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Microchip-based immunomagnetic detection of circulating tumor cells
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20270g · Cited by 400
Separation and detection of rare cells in a microfluidic disk via negative selection
Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M. (2011) · Lab Chip · doi:10.1039/c0lc00332h · Cited by 72
Cited by
Current detection technologies for circulating tumor cells
Shen, Z., Wu, A., & Chen, X. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00803h · Cited by 433
Honrado, C., Bisegna, P., Swami, N. S., & Caselli, F. (2021) · Lab on a Chip · doi:10.1039/d0lc00840k · Cited by 222
Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids
Neoh, K. H., Hassan, A. A., Chen, A., Sun, Y., Liu, P., Xu, K.-F., Wong, A. S. T., & Han, R. P. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.006 · Cited by 44
Han, S.-I., Kim, H. S., Han, K.-H., & Han, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00850k · Cited by 40
Self-citation
Metadata
- Authors
- Han, S.-I., & Han, K.-H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-10-01
- Volume
- 87
- Issue
- 20
- Pages
- 10585-10592
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2286903909
- Cited by
- 59
- References
- 3
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.