CoChat

Separation and detection of rare cells in a microfluidic disk via negative selection

The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.

Abstract

Cyto-analysis of rare cells often requires separation and detection with each procedure posing substantial challenges. This paper presents a disk-based microfluidic platform for both procedures via an immunomagnetic negative selection process. The microfluidic platform's unique features include a multistage magnetic gradient to trap labeled cells in double trapping areas, drainage of fluid to substantially shorten detection time, and a bin-like regions to capture target cells to facilitate a seamless enumeration process. Proof-of-concept was conducted using MCF7 as target rare cells (stained with anti-cytokeratin-FITC antibodies) spiked into Jurkat Clone E6-1 non-target cells (labeled with anti-CD45-PE and anti-PE BD magnetic beads). Then, mononuclear cells (MNC) from healthy blood donors were mixed with MCF7s, modeling rare cells, and tested in the disk. Results show a non-linear magnetic coupling effect of the multistage magnet substantially increased the trapping efficacy over that of a single magnet, contributing to the depletion rate of Jurkats, which reaches 99.96%. Detection time is extensively shortened by depletion of 95% of non-cell-containing fluid in the collection area. The average yield of detected MCF7 cells is near-constant 60 ± 10% over a wide range of rarity from 10(-3) to 10(-6) and this yield also holds for the MCF7/MNC complex mixture. Comparison with autoMACS and BD IMagnet separators revealed the average yield from the disk (60%) is superior to that of autoMACS (37.3%) and BD IMagnet (48.3%). The advantages of near-constant yield, roughly 30 min of operation, an acceptable level of cell loss, and potentially low cost system should aid in cyto-analysis of rare cells.

Overview

Integrity signals

Registry

Crossref · 10.1039/c0lc00332h

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. C. Alix-Panabieres and K.Pantel, Am. Assoc. Cancer Res. 101st Annual Meeting, Education Book, 2010, Apr. 17–21, pp. 179–185

Cited by

See all 73

Metadata

Authors
Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M.
Affiliations
National Taiwan University (TW)
Corresponding author
Wo, Andrew M.
Venue
Lab Chip
Published
2011
Volume
11
Issue
3
Pages
474-483
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2077346543
Cited by
72
References
47
Citations by year
2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 8 · 2018: 3 · 2017: 4 · 2016: 10 · 2015: 7 · 2014: 7 · 2013: 8 · 2012: 11
FWCI
4.15
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Council
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
rare cell detection, negative selection, immunomagnetic separation, magnetic gradient, MCF-7 cells, mononuclear cells, cell counting
MeSH terms
Antibodies, Monoclonal, Humans, Keratins, Leukocytes, Leukocyte Common Antigens, Immunomagnetic Separation, Jurkat Cells, Cell Line, Tumor, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Separation and detection of rare cells in a microfluidic disk via negative selection. https://app.cochat.ai/papers/10.1039/c0lc00332h
The paper
Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M. (2011). Separation and detection of rare cells in a microfluidic disk via negative selection. Lab Chip. https://doi.org/10.1039/c0lc00332h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.