Nearly 1000 Protein Identifications from 50 ng of Xenopus laevis Zygote Homogenate Using Online Sample Preparation on a Strong Cation Exchange Monolith Based Microreactor Coupled with Capillary Zone Electrophoresis
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A sulfonate-silica hybrid strong cation exchange monolith microreactor was synthesized and coupled to a linear polyacrylamide coated capillary for online sample preparation and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) bottom-up proteomic analysis. The protein sample was loaded onto the microreactor in an acidic buffer. After online reduction, alkylation, and digestion with trypsin, the digests were eluted with 200 mM ammonium bicarbonate at pH 8.2 for CZE-MS/MS analysis using 1 M acetic acid as the background electrolyte. This combination of basic elution and acidic background electrolytes results in both sample stacking and formation of a dynamic pH junction. 369 protein groups and 1274 peptides were identified from 50 ng of Xenopus laevis zygote homogenate, which is comparable with an offline sample preparation method, but the time required for sample preparation was decreased from over 24 h to less than 40 min. Dramatically improved performance was produced by coupling the reactor to a longer separation capillary (∼100 cm) and a Q Exactive HF mass spectrometer. 975 protein groups and 3749 peptides were identified from 50 ng of Xenopus protein using the online sample preparation method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128
Self-citationZhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103
Self-citationZhang, Z., Yan, X., Sun, L., Zhu, G., & Dovichi, N. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00789 · Cited by 67
Self-citationZhang, Z., Sun, L., Zhu, G., Yan, X., & Dovichi, N. J. (2015) · Talanta · doi:10.1016/j.talanta.2015.01.040 · Cited by 53
Self-citation
Cited by
Recent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Týčová, A., Ledvina, V., & Klepárník, K. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600366 · Cited by 99
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Self-citationYang, Z., Shen, X., Chen, D., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02466 · Cited by 43
Self-citationZhang, Z., Hebert, A. S., Westphall, M. S., Qu, Y., Coon, J. J., & Dovichi, N. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02991 · Cited by 30
Self-citationZhang, Z., Zhu, G., Peuchen, E. H., & Dovichi, N. J. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2084-8 · Cited by 24
“Solid phase extraction (SPE) monoliths typically fall into two types: reversed phase (RP) [12–14], and ion exchange [15, 16, 29].”
BackgroundSelf-citation
Metadata
- Authors
- Zhang, Z., Sun, L., Zhu, G., Cox, O. F., Huber, P. W., & Dovichi, N. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-15
- Volume
- 88
- Issue
- 1
- Pages
- 877-882
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2275760082
- Cited by
- 46
- References
- 5
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.