The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection
Abstract
Here, a dual-wavelength ratiometric electrochemiluminescence (ECL) approach is reported based on resonance energy transfer (RET) from graphite-like carbon nitride nanosheet (g-C3N4 NS) to Ru(bpy)3(2+) for sensitive detection of microRNA (miRNA). In this approach, Au nanoparticles (Au NPs) functionalized g-C3N4 NS nanohybrid (Au-g-C3N4 NH) coated on glassy carbon electrode (GCE) could exhibit strong and stable ECL emissions with emission peak centered at 460 nm. The ECL emission at such wavelength matched well with the absorption peak of Ru(bpy)3(2+) as well as impeccably stimulating the emission of Ru(bpy)3(2+) at the wavelength of 620 nm, producing ECL-RET with high efficiency. Thus, based on the ECL signals quenching at 460 nm and increasing at 620 nm, a dual-wavelength ratiometric ECL-RET system was achieved. This system was then utilized for determination of target miRNA. With the attachment of thiol-modified molecular beacon on Au-g-C3N4 NH, target miRNA hybridized with the molecular beacon to form a DNA-RNA duplex. The obtained DNA-RNA duplex could be cleaved by duplex-specific nuclease to release target miRNA which would take part in the next cycle for further hybridization. Finally, the introducing of Ru(bpy)3(2+) was through the probe DNA-Ru(bpy)3(2+) complementary with the rest single-strand DNA on electrode. By measuring the ratio of ECL(460 nm)/ECL(620 nm), we could accurately quantify the concentration of miRNA-21 in a wide range from 1.0 fM to 1.0 nM. This work provides an important reference for the study of dual-wavelength ECL ratiometry and also exhibits potential capability in the detection of nucleic acids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced Photoresponsive Ultrathin Graphitic-Phase C3N4Nanosheets for Bioimaging
Zhang, X., Xie, X., Wang, H., Zhang, J., Pan, B., & Xie, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja308249k · Cited by 2,136
Human Argonaute2 mediates RNA cleavage targeted by miRNAs and siRNAs
Meister, G., Landthaler, M., Patkaniowska, A., Dorsett, Y., Teng, G., & Tuschl, T. (2004) · Molecular Cell · doi:10.1016/j.molcel.2004.07.007 · Cited by 2,052
Ma, T. Y., Tang, Y., Dai, S., & Qiao, S. Z. (2014) · Small · doi:10.1002/smll.201303827 · Cited by 497
Chen, L., Zeng, X., Si, P., Chen, Y., Chi, Y., Kim, D.-H., & Chen, G. (2014) · Analytical Chemistry · doi:10.1021/ac403635f · Cited by 421
Sol Processing of Conjugated Carbon Nitride Powders for Thin‐Film Fabrication
Zhang, J., Zhang, M., Lin, L., & Wang, X. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501001 · Cited by 420
Cheng, C., Huang, Y., Tian, X., Zheng, B., Li, Y., Yuan, H., Xiao, D., Xie, S., & Choi, M. M. F. (2012) · Analytical Chemistry · doi:10.1021/ac300205w · Cited by 389
Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
Duan, R., Zuo, X., Wang, S., Quan, X., Chen, D., Chen, Z., Jiang, L., Fan, C., & Xia, F. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311313b · Cited by 355
Lin, L.-S., Cong, Z.-X., Li, J., Ke, K.-M., Guo, S.-S., Yang, H.-H., & Chen, G.-N. (2014) · Journal of Materials Chemistry B · doi:10.1039/c3tb21479f · Cited by 343
Fluorescent Biomembrane Probe for Ratiometric Detection of Apoptosis
Shynkar, V. V., Klymchenko, A. S., Kunzelmann, C., Duportail, G., Muller, C. D., Demchenko, A. P., Freyssinet, J.-M., & Mely, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068008h · Cited by 335
Cited by
Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing
Lv, M., Zhou, W., Tavakoli, H., Bautista, C., Xia, J., Wang, Z., & Li, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112947 · Cited by 331
Metadata
- Authors
- Feng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-15
- Volume
- 88
- Issue
- 1
- Pages
- 937-944
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2336375238
- Cited by
- 320
- References
- 26
- FWCI
- 12.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.5b03670
- The paper
- Feng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y. (2016). Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b03670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.