Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection

Feng, Qiu-Mei, Shen, Yi-Zhong, Li, Mei-Xing, Zhang, Zhuo-Lei, Zhao, Wei, Xu, Jing-Juan, Chen, Hong-Yuan·2016·Analytical Chemistry

Abstract

Here, a dual-wavelength ratiometric electrochemiluminescence (ECL) approach is reported based on resonance energy transfer (RET) from graphite-like carbon nitride nanosheet (g-C3N4 NS) to Ru(bpy)3(2+) for sensitive detection of microRNA (miRNA). In this approach, Au nanoparticles (Au NPs) functionalized g-C3N4 NS nanohybrid (Au-g-C3N4 NH) coated on glassy carbon electrode (GCE) could exhibit strong and stable ECL emissions with emission peak centered at 460 nm. The ECL emission at such wavelength matched well with the absorption peak of Ru(bpy)3(2+) as well as impeccably stimulating the emission of Ru(bpy)3(2+) at the wavelength of 620 nm, producing ECL-RET with high efficiency. Thus, based on the ECL signals quenching at 460 nm and increasing at 620 nm, a dual-wavelength ratiometric ECL-RET system was achieved. This system was then utilized for determination of target miRNA. With the attachment of thiol-modified molecular beacon on Au-g-C3N4 NH, target miRNA hybridized with the molecular beacon to form a DNA-RNA duplex. The obtained DNA-RNA duplex could be cleaved by duplex-specific nuclease to release target miRNA which would take part in the next cycle for further hybridization. Finally, the introducing of Ru(bpy)3(2+) was through the probe DNA-Ru(bpy)3(2+) complementary with the rest single-strand DNA on electrode. By measuring the ratio of ECL(460 nm)/ECL(620 nm), we could accurately quantify the concentration of miRNA-21 in a wide range from 1.0 fM to 1.0 nM. This work provides an important reference for the study of dual-wavelength ECL ratiometry and also exhibits potential capability in the detection of nucleic acids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b03670

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 320

Metadata

Authors
Feng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y.
Venue
Analytical Chemistry
Published
2015-12-15
Volume
88
Issue
1
Pages
937-944
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2336375238
Cited by
320
References
26
FWCI
12.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection. https://app.cochat.ai/papers/10.1021/acs.analchem.5b03670
The paper
Feng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y. (2016). Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b03670

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.