The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Dual-Wavelength Electrochemiluminescence Ratiometry Based on Resonance Energy Transfer between Au Nanoparticles Functionalized g-C3N4 Nanosheet and Ru(bpy)32+ for microRNA Detection
Abstract
Here, a dual-wavelength ratiometric electrochemiluminescence (ECL) approach is reported based on resonance energy transfer (RET) from graphite-like carbon nitride nanosheet (g-C3N4 NS) to Ru(bpy)3(2+) for sensitive detection of microRNA (miRNA). In this approach, Au nanoparticles (Au NPs) functionalized g-C3N4 NS nanohybrid (Au-g-C3N4 NH) coated on glassy carbon electrode (GCE) could exhibit strong and stable ECL emissions with emission peak centered at 460 nm. The ECL emission at such wavelength matched well with the absorption peak of Ru(bpy)3(2+) as well as impeccably stimulating the emission of Ru(bpy)3(2+) at the wavelength of 620 nm, producing ECL-RET with high efficiency. Thus, based on the ECL signals quenching at 460 nm and increasing at 620 nm, a dual-wavelength ratiometric ECL-RET system was achieved. This system was then utilized for determination of target miRNA. With the attachment of thiol-modified molecular beacon on Au-g-C3N4 NH, target miRNA hybridized with the molecular beacon to form a DNA-RNA duplex. The obtained DNA-RNA duplex could be cleaved by duplex-specific nuclease to release target miRNA which would take part in the next cycle for further hybridization. Finally, the introducing of Ru(bpy)3(2+) was through the probe DNA-Ru(bpy)3(2+) complementary with the rest single-strand DNA on electrode. By measuring the ratio of ECL(460 nm)/ECL(620 nm), we could accurately quantify the concentration of miRNA-21 in a wide range from 1.0 fM to 1.0 nM. This work provides an important reference for the study of dual-wavelength ECL ratiometry and also exhibits potential capability in the detection of nucleic acids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced Photoresponsive Ultrathin Graphitic-Phase C3N4Nanosheets for Bioimaging
Zhang, X., Xie, X., Wang, H., Zhang, J., Pan, B., & Xie, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja308249k · Cited by 2,136
Human Argonaute2 mediates RNA cleavage targeted by miRNAs and siRNAs
Meister, G., Landthaler, M., Patkaniowska, A., Dorsett, Y., Teng, G., & Tuschl, T. (2004) · Molecular Cell · doi:10.1016/j.molcel.2004.07.007 · Cited by 2,052
Ma, T. Y., Tang, Y., Dai, S., & Qiao, S. Z. (2014) · Small · doi:10.1002/smll.201303827 · Cited by 497
Chen, L., Zeng, X., Si, P., Chen, Y., Chi, Y., Kim, D.-H., & Chen, G. (2014) · Analytical Chemistry · doi:10.1021/ac403635f · Cited by 421
Sol Processing of Conjugated Carbon Nitride Powders for Thin‐Film Fabrication
Zhang, J., Zhang, M., Lin, L., & Wang, X. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501001 · Cited by 420
Cheng, C., Huang, Y., Tian, X., Zheng, B., Li, Y., Yuan, H., Xiao, D., Xie, S., & Choi, M. M. F. (2012) · Analytical Chemistry · doi:10.1021/ac300205w · Cited by 389
Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
Duan, R., Zuo, X., Wang, S., Quan, X., Chen, D., Chen, Z., Jiang, L., Fan, C., & Xia, F. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311313b · Cited by 355
Lin, L.-S., Cong, Z.-X., Li, J., Ke, K.-M., Guo, S.-S., Yang, H.-H., & Chen, G.-N. (2014) · Journal of Materials Chemistry B · doi:10.1039/c3tb21479f · Cited by 343
Fluorescent Biomembrane Probe for Ratiometric Detection of Apoptosis
Shynkar, V. V., Klymchenko, A. S., Kunzelmann, C., Duportail, G., Muller, C. D., Demchenko, A. P., Freyssinet, J.-M., & Mely, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068008h · Cited by 335
Dissolution and Liquid Crystals Phase of 2D Polymeric Carbon Nitride
Zhou, Z., Wang, J., Yu, J., Shen, Y., Li, Y., Liu, A., Liu, S., & Zhang, Y. (2015) · Journal of the American Chemical Society · doi:10.1021/ja512179x · Cited by 333
Self-citationZhao, C., Zhang, X., Li, K., Zhu, S., Guo, Z., Zhang, L., Wang, F., Fei, Q., Luo, S., Shi, P., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b03248 · Cited by 282
Lei, Y.-M., Huang, W.-X., Zhao, M., Chai, Y.-Q., Yuan, R., & Zhuo, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01445 · Cited by 161
Xiong, E., Zhang, X., Liu, Y., Zhou, J., Yu, P., Li, X., & Chen, J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01402 · Cited by 149
Liao, Y., Huang, R. Q., Ma, Z., Wu, Y., Zhou, X., & Xing, D. (2014) · Analytical Chemistry · doi:10.1021/ac5007427 · Cited by 126
Zhang, L., Han, Y., Zhao, F., Shi, G., & Tian, Y. (2015) · Analytical Chemistry · doi:10.1021/ac504448m · Cited by 124
Lin, X., Zhang, C., Huang, Y., Zhu, Z., Chen, X., & Yang, C. J. (2013) · Chemical Communications · doi:10.1039/c3cc43224f · Cited by 111
MS4, a seminaphthofluorescein-based chemosensor for the ratiometric detection of Hg(ii)
Nolan, E. M., & Lippard, S. J. (2005) · Journal of Materials Chemistry · doi:10.1039/b501615k · Cited by 106
A ratiometric fluorescent system for carboxylesterase detection with AIE dots as FRET donors
Wu, Y., Huang, S., Zeng, F., Wang, J., Yu, C., Huang, J., Xie, H., & Wu, S. (2015) · Chemical Communications · doi:10.1039/c5cc04771d · Cited by 105
Hao, N., Li, X., Zhang, H., Xu, J., & Chen, H. (2014) · Chemical Communications · doi:10.1039/c4cc06801g · Cited by 97
Self-citationZhao, H., Liang, R., Wang, J., & Qiu, J. (2015) · Chemical Communications · doi:10.1039/c5cc03678j · Cited by 93
Qin, J., Yang, Z., Wang, G.-Q., & Li, C.-R. (2015) · Tetrahedron Letters · doi:10.1016/j.tetlet.2015.07.023 · Cited by 73
Zhang, Y., Guo, X., Tian, X., Liu, A., & Jia, L. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.100 · Cited by 42
Meier, R. J., Simbürger, J. M. B., Soukka, T., & Schäferling, M. (2015) · Chemical Communications · doi:10.1039/c5cc00144g · Cited by 31
Chen, H., Tan, X., Zhang, J., Lu, Q., Ou, X., Ruo, Y., & Chen, S. (2014) · RSC Advances · doi:10.1039/c4ra09616a · Cited by 27
Self-citationKawagoe, R., Takashima, I., Usui, K., Kanegae, A., Ozawa, Y., & Ojida, A. (2015) · ChemBioChem · doi:10.1002/cbic.201500249 · Cited by 12
Cited by
Zhou, Z., Zhang, Y., Shen, Y., Liu, S., & Zhang, Y. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00840f · Cited by 617
Self-citationWang, A., Wang, C., Fu, L., Wong-Ng, W., & Lan, Y. (2017) · Nano-Micro Letters · doi:10.1007/s40820-017-0148-2 · Cited by 498
Emerging graphitic carbon nitride-based materials for biomedical applications
Liao, G., He, F., Li, Q., Zhong, L., Zhao, R., Che, H., Gao, H., & Fang, B. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100666 · Cited by 340
Nanomaterials-based sensitive electrochemiluminescence biosensing
Chen, Y., Zhou, S., Li, L., & Zhu, J.-J. (2017) · Nano Today · doi:10.1016/j.nantod.2016.12.013 · Cited by 337
Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing
Lv, M., Zhou, W., Tavakoli, H., Bautista, C., Xia, J., Wang, Z., & Li, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112947 · Cited by 331
Metadata
- Authors
- Feng, Q.-M., Shen, Y.-Z., Li, M.-X., Zhang, Z.-L., Zhao, W., Xu, J.-J., & Chen, H.-Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-15
- Volume
- 88
- Issue
- 1
- Pages
- 937-944
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2336375238
- Cited by
- 320
- References
- 26
- FWCI
- 12.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.