CoChat

Native MS Analysis of Bacteriorhodopsin and an Empty Nanodisc by Orthogonal Acceleration Time-of-Flight, Orbitrap and Ion Cyclotron Resonance

Open access
Campuzano, Iain D. G., Li, Huilin, Bagal, Dhanashri, Lippens, Jennifer L., Svitel, Juraj, Kurzeja, Robert J. M., Xu, Han, Schnier, Paul D., Loo, Joseph A. · 2016 · Analytical Chemistry
Cited by 54

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Over the past two decades, orthogonal acceleration time-of-flight has been the de facto analyzer for solution and membrane-soluble protein native mass spectrometry (MS) studies; this however is gradually changing. Three MS instruments are compared, the Q-ToF, Orbitrap, and the FT-ICR, to analyze, under native instrument and buffer conditions, the seven-transmembrane helical protein bacteriorhodopsin-octylglucoside micelle and the empty nanodisc (MSP1D1-Nd) using both MS and tandem-MS modes of operation. Bacteriorhodopsin can be released from the octylglucoside-micelle efficiently on all three instruments (MS-mode), producing a narrow charge state distribution (z = 8+ to 10+) by either increasing the source lens or collision cell (or HCD) voltages. A lower center-of-mass collision energy (0.20-0.41 eV) is required for optimal bacteriorhodopsin liberation on the FT-ICR, in comparison to the Q-ToF and Orbitrap instruments (0.29-2.47 eV). The empty MSP1D1-Nd can be measured with relative ease on all three instruments, resulting in a highly complex spectrum of overlapping, polydisperse charge states. There is a measurable difference in MSP1D1-Nd charge state distribution (z = 15+ to 26+), average molecular weight (141.7 to 169.6 kDa), and phospholipid incorporation number (143 to 184) under low activation conditions. Utilizing tandem-MS, bacteriorhodopsin can be effectively liberated from the octylglucoside-micelle by collisional (Q-ToF and FT-ICR) or continuous IRMPD activation (FT-ICR). MSP1D1-Nd spectral complexity can also be significantly reduced by tandem-MS (Q-ToF and FT-ICR) followed by mild collisional or continuous IRMPD activation, resulting in a spectrum in which the charge state and phospholipid incorporation levels can easily be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.6b03762

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Campuzano, I. D. G., Li, H., Bagal, D., Lippens, J. L., Svitel, J., Kurzeja, R. J. M., Xu, H., Schnier, P. D., & Loo, J. A.
Venue
Analytical Chemistry
Published
2016-12-01
Volume
88
Issue
24
Pages
12427-12436
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2551701542
Cited by
54
References
8
FWCI
3.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.