The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements
Open accessAbstract
Collision cross section (CCS) measurements resulting from ion mobility–mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values ( DT CCS N2 ) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DT CCS N2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DT CCS N2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry‐based metabolomics
Dettmer, K., Aronov, P. A., & Hammock, B. D. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20108 · Cited by 2,241
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Quantifying Uncertainty in Analytical Measurement
Silva, R. A., Bremser, W., Brzyski, A., Kaarls, R., Kaus, R., Magnusson, B., Amico, D. E., Robouch, P. B., Rösslein, M., van der, V. A., et al. (2012) · Cited by 1,141
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Gros, M., Petrović, M., & Barceló, D. (2006) · Talanta · doi:10.1016/j.talanta.2006.05.024 · Cited by 753
Screening Newborns for Inborn Errors of Metabolism by Tandem Mass Spectrometry
Wilcken, B., Wiley, V., Hammond, J., & Carpenter, K. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa025225 · Cited by 677
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Self-citationMay, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Self-citationJurneczko, E., & Barran, P. E. (2011) · The Analyst · doi:10.1039/c0an00373e · Cited by 328
Ion Mobility Derived Collision Cross Sections to Support Metabolomics Applications
Paglia, G., Williams, J. P., Menikarachchi, L., Thompson, J. W., Tyldesley-Worster, R., Halldórsson, S., Rolfsson, O., Moseley, A., Grant, D., Langridge, J., et al. (2014) · Analytical Chemistry · doi:10.1021/ac500405x · Cited by 319
Ion mobility–mass spectrometry: a new paradigm for proteomics
McLean, J. A., Ruotolo, B. T., Gillig, K. J., & Russell, D. H. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.10.003 · Cited by 309
Self-citationPaglia, G., Angel, P., Williams, J. P., Richardson, K., Olivos, H. J., Thompson, J. W., Menikarachchi, L., Lai, S., Walsh, C., Moseley, A., et al. (2015) · Analytical Chemistry · doi:10.1021/ac503715v · Cited by 295
Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00079-3 · Cited by 219
Zhou, Z., Shen, X., Tu, J., & Zhu, Z.-J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03091 · Cited by 212
Wu, C., Siems, W. F., Klasmeier, J., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac990601c · Cited by 207
Fenn, L. S., Kliman, M., Mahsut, A., Zhao, S. R., & McLean, J. A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2666-3 · Cited by 198
Self-citationHines, K. M., May, J. C., McLean, J. A., & Xu, L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01728 · Cited by 188
Self-citationIon Mobility Collision Cross Section Compendium
May, J. C., Morris, C. B., & McLean, J. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04905 · Cited by 183
Self-citationIon mobility–mass spectrometry for structural proteomics
Zhong, Y., Hyung, S.-J., & Ruotolo, B. T. (2012) · Expert Review of Proteomics · doi:10.1586/epr.11.75 · Cited by 179
Baker, E. S., Clowers, B. H., Li, F., Tang, K., Tolmachev, A. V., Prior, D. C., Belov, M. E., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.03.031 · Cited by 143
Self-citationValentine, S. J., Kulchania, M., Barnes, C. A. S., & Clemmer, D. E. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00511-5 · Cited by 143
Development of a new ion mobility time-of-flight mass spectrometer
Ibrahim, Y., Baker, E. S., Danielson, W., Norheim, R. V., Prior, D. C., Anderson, G., Belov, M. E., & Smith, R. D. (2014) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.07.034 · Cited by 122
Self-citationEnvironmental Mass Spectrometry
Lebedev, А. T. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092604 · Cited by 115
Drift Tube-Mass Spectrometer for Studies of Low-Energy Ion-Molecule Reactions
McDaniel, E. W., Martin, D. W., & Barnes, W. S. (1962) · Review of Scientific Instruments · doi:10.1063/1.1717656 · Cited by 111
Dodds, J. N., May, J. C., & MCLEAN, J. A. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04171 · Cited by 111
Self-citationImproving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface
Ibrahim, Y., Tang, K., Tolmachev, A. V., Shvartsburg, A. A., & Smith, R. D. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.06.005 · Cited by 100
Self-citationMetz, T., Baker, E. S., Schymanski, E., Renslow, R. S., Thomas, D., Causon, T. J., Webb, I., Hann, S., Smith, R. D., & Teeguarden, J. (2016) · Bioanalysis · doi:10.4155/bio-2016-0244 · Cited by 92
Self-citationAdvanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge
May, J. C., & MCLEAN, J. A. J. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041734 · Cited by 91
Self-citationMay, J. C., Dodds, J. N., Kurulugama, R. T., Stafford, G. C., Fjeldsted, J. C., & MCLEAN, J. A. J. (2015) · The Analyst · doi:10.1039/c5an00923e · Cited by 58
Self-citationDilger, J. M., Valentine, S. J., Glover, M. S., Ewing, M. A., & Clemmer, D. E. (2012) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2012.05.001 · Cited by 35
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Self-citationA Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citation
Metadata
- Authors
- Stow, S. M., Causon, T. J., Zheng, X., Kurulugama, R. T., Mairinger, T., May, J. C., Rennie, E. E., Baker, E. S., Smith, R. D., McLean, J. A., Hann, S., & Fjeldsted, J. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-16
- Volume
- 89
- Issue
- 17
- Pages
- 9048-9055
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2740977550
- Cited by
- 534
- References
- 31
- FWCI
- 19.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.