CoChat

Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices

Moore, Thomas A., Brodersen, Peter, Young, Edmond W. K. · 2017 · Analytical Chemistry
Cited by 49

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Poly(dimethylsiloxane) (PDMS) is a commonly used elastomer for fabricating microfluidic devices, but it has previously been shown to absorb hydrophobic molecules. Although this has been demonstrated for molecules such as estrogen and Nile Red, the absorption of small hydrophobic molecules in PDMS specifically used to treat cancer and its subsequent impact on cytotoxicity measurements and assays have not been investigated. This is critical for the development of microfluidic chemosensitivity and resistance assay (CSRA) platforms that have shown potential to help guide clinical therapy selection and which rely on the accuracy of the readout involving interactions between patient-derived cells and cancer drugs. It is thus important to address the issue of drug absorption into device material. We investigated drug absorption into microfluidic devices by treating multiple myeloma (MM) tumor cells with two MM drugs (bortezomib (BTZ) and carfilzomib (CFZ)) in devices fabricated using three different materials (polystyrene (PS), cyclo-olefin polymer (COP), and PDMS). Half-maximal inhibitory concentrations (IC 50 ) were obtained for each drug–material combination, and an increase in IC 50 of ∼4.3× was observed in PDMS devices compared to both thermoplastic devices. Additionally, each MM drug was exposed to polymer samples, and samples were analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to characterize adsorption and absorption of the drugs into each material. ToF-SIMS data showed the bias observed in IC 50 values found in PDMS devices was directly related to the absorption of drug during dose–response experiments. Specifically, BTZ and CFZ absorption in both PS and COP were all in the range of ∼100–300 nm, whereas BTZ and CFZ absorption in PDMS was ∼5.0 and ∼3.5 μm, respectively. These results highlight the biases that exist in PDMS devices and the importance of material selection in microfluidic device design, especially in applications involving drug cytotoxicity and hydrophobic molecules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b02351

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 49

Metadata

Authors
Moore, T. A., Brodersen, P., & Young, E. W. K.
Venue
Analytical Chemistry
Published
2017-10-17
Volume
89
Issue
21
Pages
11391-11398
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2761183585
Cited by
49
References
6
FWCI
1.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices. https://app.cochat.ai/papers/10.1021/acs.analchem.7b02351
The paper
Moore, T. A., Brodersen, P., & Young, E. W. K. (2017). Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b02351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.