Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Monitoring of Heparin Activity in Live Rats Using Metal–Organic Framework Nanosheets as Peroxidase Mimics

Cheng, Hanjun, Liu, Yufeng, Hu, Yihui, Ding, Yubin, Lin, Shichao, Cao, Wen, Wang, Qian, Wu, Jiangjiexing, Muhammad, Faheem, Zhao, Xiaozhi, Zhao, Dan, Li, Zhe, Xing, Hang, Wei, Hui·2017·Analytical Chemistry

Abstract

Metal-organic framework (MOF) nanosheets are a class of two-dimensional (2D) porous and crystalline materials that hold promise for catalysis and biodetection. Although 2D MOF nanosheets have been utilized for in vitro assays, ways of engineering them into diagnostic tools for live animals are much less explored. In this work, a series of MOF nanosheets are successfully engineered into a highly sensitive and selective diagnostic platform for in vivo monitoring of heparin (Hep) activity. The iron-porphyrin derivative is selected as a ligand to synthesize a series of archetypical MOF nanosheets with intrinsic heme-like catalytic sites, mimicking peroxidase. Hep-specific AG73 peptides as recognition motifs are physically adsorbed onto MOF nanosheets, blocking active sites from nonspecific substrate-catalyst interaction. Because of the highly specific interaction between Hep and AG73, the activity of AG73-MOF nanosheets is restored upon the binding of Hep, but not Hep analogues and other endogenous biomolecules. Furthermore, by taking advantages of biocompatibility and diagnostic property enabled by AG73-MOF nanosheets, the elimination process of Hep in live rats is quantitatively monitored by coupling with microdialysis technology. This work expands the biomedical applications of 2D MOF nanomaterials and provides access to a promising in vivo diagnostic platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b02895

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Cited by

See all 267

Metadata

Authors
Cheng, H., Liu, Y., Hu, Y., Ding, Y., Lin, S., Cao, W., Wang, Q., Wu, J., Muhammad, F., Zhao, X., Zhao, D., Li, Z., Xing, H., & Wei, H.
Venue
Analytical Chemistry
Published
2017-10-23
Volume
89
Issue
21
Pages
11552-11559
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2764092097
Cited by
267
References
48
FWCI
13.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Monitoring of Heparin Activity in Live Rats Using Metal–Organic Framework Nanosheets as Peroxidase Mimics. https://app.cochat.ai/papers/10.1021/acs.analchem.7b02895
The paper
Cheng, H., Liu, Y., Hu, Y., Ding, Y., Lin, S., Cao, W., Wang, Q., Wu, J., Muhammad, F., Zhao, X., Zhao, D., Li, Z., Xing, H., & Wei, H. (2017). Monitoring of Heparin Activity in Live Rats Using Metal–Organic Framework Nanosheets as Peroxidase Mimics. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b02895

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.