Charge Variant Analysis of Monoclonal Antibodies Using Direct Coupled pH Gradient Cation Exchange Chromatography to High-Resolution Native Mass Spectrometry
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Charge variant analysis (CVA) of monoclonal antibodies (mAbs) using cation exchange chromatography is routinely used as a fingerprint of the distribution of posttranslational modifications present on the molecule. Traditional salt or pH based eluents are not suited for direct coupling to mass spectrometry due to nonvolatility or high ionic strength. This makes further analysis complicated when an alteration in the charge variant profile or the emergence of an additional peak is encountered. Here, the use of pH gradient elution using volatile, low ionic strength buffers is reported with direct coupling to high-resolution Orbitrap mass spectrometry. The development of a universal method based on pH elution was explored using a number of mAb drug products. Optimized methods facilitated the separation and identification of charge variants including individual glycoforms of the mAbs investigated using the same buffer system but with tailored gradient slopes. The developed method represents an exciting advance for the characterization of biopharmaceuticals as intact entities through the combination of native charge variant separations with high-resolution native mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Dynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194
Leblanc, Y., Ramon, C., Bihoreau, N., & Chevreux, G. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.02.017 · Cited by 127
Muneeruddin, K., Nazzaro, M., & Kaltashov, I. A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02982 · Cited by 98
Muneeruddin, K., Bobst, C. E., Frenkel, R., Houde, D., Turyan, I., Sosic, Z., & Kaltashov, I. A. (2017) · The Analyst · doi:10.1039/c6an02041k · Cited by 38
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Dai, J., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04396 · Cited by 46
Graf, T., Heinrich, K., Grunert, I., Wegele, H., Haberger, M., Bulau, P., & Leiss, M. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113251 · Cited by 46
Diehm, J., Witting, L., Kirschhöfer, F., Brenner-Weiß, G., & Franzreb, M. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-05023-9 · Cited by 2
Metadata
- Authors
- Füssl, F., Cook, K., Scheffler, K., Farrell, A., Mittermayr, S., & Bones, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-01
- Volume
- 90
- Issue
- 7
- Pages
- 4669-4676
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2793987949
- Cited by
- 132
- References
- 5
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.