CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

A Middle-Up Approach with Online Capillary Isoelectric Focusing/Mass Spectrometry for In-Depth Characterization of Cetuximab Charge Heterogeneity

Dai, Jun, Zhang, Yingru · 2018 · Analytical Chemistry

Abstract

Previously, we reported a new online capillary isoelectric focusing/mass spectrometric (CIEF/MS) method for intact monoclonal antibody (mAb) charge variant analysis that uses an electrokinetically pumped sheath-flow nanospray ion source on a time-of-flight (TOF) MS with a pressure-assisted chemical mobilization. The direct online CIEF/MS method exhibited excellent resolution of charge variants conforming to those of imaged capillary isoelectric focusing with ultraviolet detection (iCIEF/UV). However, for complex mAbs, CIEF/MS spectra of the intact charge variant peaks may be too convoluted to be effectively interpreted. In the present study, we implemented a middle-up approach to enhance the capability of the CIEF/MS method for characterizing complex mAb charge variants by reducing sample complexity. To demonstrate such a strategy, we fragmented cetuximab through IdeS enzymatic cleavage and dithiothreitol (DTT) reduction. For the first time, online CIEF/MS resolved the complex charge variants of cetuximab at subunit level, corroborating the profiles obtained by iCIEF/UV. Furthermore, high-resolution TOF mass spectra with high mass accuracy were obtained for the eight charge variants separated by CIEF/MS after IdeS cleavage and for the 11 charge variants after IdeS digestion with subsequent DTT reduction. In-depth analyses revealed the identities of all charge variants and pinpointed the causes of charge heterogeneity, which are in accord with those reported in the literature. The main sources of charge heterogeneity of cetuximab were identified as terminal lysine on the Fc domain (up to one on each single-chain Fc), glycolylneuraminic acid residues on the Fd' domain (up to two on each Fd'), and likely several deamidation species on the Fd' domain. No charge heterogeneity contribution was found from light chain. The in-depth characterization of complex charge variants for cetuximab demonstrates the remarkable capability of this middle-up CIEF/MS approach. This novel workflow holds great potential for detecting and elucidating charge variants to help understand proteins with complex charge heterogeneity.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b04396

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Cited by

See all 46

Metadata

Authors
Dai, J., & Zhang, Y.
Affiliations
Bristol-Myers Squibb (United States) (US)
Corresponding author
Dai, Jun
Venue
Analytical Chemistry
Published
2018-11-19
Volume
90
Issue
24
Pages
14527-14534
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2900473322
Cited by
46
References
49
Citations by year
2026: 1 · 2025: 1 · 2024: 5 · 2023: 2 · 2022: 8 · 2021: 11 · 2020: 10 · 2019: 8
FWCI
3.13
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
Keywords
cetuximab, charge heterogeneity, dithiothreitol reduction, deamidation, sample complexity reduction
MeSH terms
Cetuximab, Bacterial Proteins, Dithiothreitol, Immunoglobulin Fab Fragments, Isoelectric Focusing, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Middle-Up Approach with Online Capillary Isoelectric Focusing/Mass Spectrometry for In-Depth Characterization of Cetuximab Charge Heterogeneity. https://app.cochat.ai/papers/10.1021/acs.analchem.8b04396
The paper
Dai, J., & Zhang, Y. (2018). A Middle-Up Approach with Online Capillary Isoelectric Focusing/Mass Spectrometry for In-Depth Characterization of Cetuximab Charge Heterogeneity. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b04396

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.