Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 291

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Avoiding Pre-Isolation Step in Exosome Analysis: Direct Isolation and Sensitive Detection of Exosomes Using Gold-Loaded Nanoporous Ferric Oxide Nanozymes

Open access
Boriachek, Kseniia, Masud, Mostafa Kamal, Palma, Carlos, Phan, Hoang-Phuong, Yamauchi, Yusuke, Hossain, Md. Shahriar A., Nguyen, Nam-Trung, Salomon, Carlos, Shiddiky, Muhammad J. A.·2019·Analytical Chemistry

Abstract

Most of the current exosome-analysis strategies are time-consuming and largely dependent on commercial extraction kit-based preisolation step, which requires extensive sample manipulations, costly isolation kits, reagents, tedious procedures, and sophisticated equipment and is prone to bias/artifacts. Herein we introduce a simple method for direct isolation and subsequent detection of a specific population of exosomes using an engineered superparamagnetic material with multifunctional properties, namely, gold-loaded ferric oxide nanocubes (Au-NPFe 2 O 3 NC). In this method, the Au-NPFe 2 O 3 NC were initially functionalized with a generic tetraspanin (exosomes-associated) antibody (i.e., CD63) and dispersed in sample fluids where they work as “dispersible nanocarriers” to capture the bulk population of exosomes. After magnetic collection and purification, Au-NPFe 2 O 3 NC-bound exosomes were transferred to the tissue-specific, antibody-modified, screen-printed electrode. As a proof of principle, we used a specific placental marker, placenta alkaline phosphatase (PLAP), to detect exosomes secreted from placental cells. The peroxidase-like activity of Au-NPFe 2 O 3 NC was then used to accomplish an enzyme-linked immunosorbent assay (ELISA)-based sensing protocol for naked-eye observation along with UV–visible and electrochemical detection of PLAP-specific exosomes present in placental cell-conditioned media. We demonstrated excellent agreement in analytical performance for the detection of placental cell-derived exosomes (i.e., linear dynamic range, 10 3 –10 7 exosomes/mL; limit of detection, 10 3 exosomes/mL; relative standard deviation (%RSD) of <5.5% for n = 3) using with and without commercial “total exosome isolation kit”-based preisolation step. We envisage that this highly sensitive, rapid, and inexpensive assay could be useful in quantifying specific populations of exosomes for various clinical applications, focusing on pregnancy complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b03619

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 291

Metadata

Authors
Boriachek, K., Masud, M. K., Palma, C., Phan, H.-P., Yamauchi, Y., Hossain, M. S. A., Nguyen, N.-T., Salomon, C., & Shiddiky, M. J. A.
Venue
Analytical Chemistry
Published
2019-02-08
Volume
91
Issue
6
Pages
3827-3834
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2913124957
Cited by
291
References
1
FWCI
11.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Avoiding Pre-Isolation Step in Exosome Analysis: Direct Isolation and Sensitive Detection of Exosomes Using Gold-Loaded Nanoporous Ferric Oxide Nanozymes. https://app.cochat.ai/papers/10.1021/acs.analchem.8b03619
The paper
Boriachek, K., Masud, M. K., Palma, C., Phan, H.-P., Yamauchi, Y., Hossain, M. S. A., Nguyen, N.-T., Salomon, C., & Shiddiky, M. J. A. (2019). Avoiding Pre-Isolation Step in Exosome Analysis: Direct Isolation and Sensitive Detection of Exosomes Using Gold-Loaded Nanoporous Ferric Oxide Nanozymes. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b03619

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.