Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Tuning and Predicting Mesh Size and Protein Release from Step Growth Hydrogels

Open access
Rehmann, Matthew S., Skeens, Kelsi M., Kharkar, Prathamesh M., Ford, Eden M., Maverakis, Emanual, Lee, Kelvin H., Kloxin, April M.·2017·Biomacromolecules

Abstract

Hydrogel-based depots are of growing interest for release of biopharmaceuticals; however, a priori selection of hydrogel compositions that will retain proteins of interest and provide desired release profiles remains elusive. Toward addressing this, in this work, we have established a new tool for the facile assessment of protein release from hydrogels and applied it to evaluate the effectiveness of mesh size estimations on predicting protein retention or release. Poly(ethylene glycol) (PEG)-based hydrogel depots were formed by photoinitiated step growth polymerization of four-arm PEG functionalized with norbornene (PEG-norbornene, 4% w/w to 20% w/w, M n ∼ 5 to 20 kDa) and different dithiol cross-linkers (PEG M n ∼ 1.5 kDa or enzymatically degradable peptide), creating well-defined, robust materials with a range of mesh sizes estimated with Flory–Rehner or rubber elasticity theory (∼5 to 15 nm). A cocktail of different model proteins was released from compositions of interest, and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) was used to facilely and quantitatively analyze temporal release profiles. Mesh size was predictive of retention of relatively large proteins and release of relatively small proteins. Proteins with diameters comparable to the mesh size, which is often the case for growth factors, were released by hindered diffusion and required experimental assessment of retention and release. With this knowledge, hydrogels were designed for the controlled release of a therapeutically relevant growth factor, PDGF-BB.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.biomac.7b00781

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 190

Metadata

Authors
Rehmann, M. S., Skeens, K. M., Kharkar, P. M., Ford, E. M., Maverakis, E., Lee, K. H., & Kloxin, A. M.
Venue
Biomacromolecules
Published
2017-09-14
Volume
18
Issue
10
Pages
3131-3142
ISSN
  • 1525-7797 (ISSN-L)
  • 1526-4602
OpenAlex
W2751760736
Cited by
190
References
3
FWCI
3.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tuning and Predicting Mesh Size and Protein Release from Step Growth Hydrogels. https://app.cochat.ai/papers/10.1021/acs.biomac.7b00781
The paper
Rehmann, M. S., Skeens, K. M., Kharkar, P. M., Ford, E. M., Maverakis, E., Lee, K. H., & Kloxin, A. M. (2017). Tuning and Predicting Mesh Size and Protein Release from Step Growth Hydrogels. Biomacromolecules. https://doi.org/10.1021/acs.biomac.7b00781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.