Development of Adhesive and Conductive Resilin-Based Hydrogels for Wearable Sensors
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Integrating multifunctionality such as stretchability, adhesiveness, and electroconductivity on a single protein hydrogel is highly desirable for various applications, and remains a challenge. Here we present the development of such multifunctional hydrogels based on resilin, a natural rubber-like material with remarkable extensibility and resilience. First, genetically engineered reslin-like proteins (RLPs) with varying molecular weight were biosynthesized to tune mechanical strength and stiffness of the cross-linked RLP hydrogels. Second, glycerol was incorporated into the hydrogels to endow adhesive properties. Next, a graphene-RLP conjugate was synthesized for cross-linking with the unmodified, pristine RLP to form an integrated network. The obtained hybrid hydrogel could be stretched to over four times of its original length, and self-adhered to diverse substrate surfaces due to its high adhesion strength of ∼24 kPa. Furthermore, the hybrid hydrogel showed high sensitivity, with a gauge factor of 3.4 at 200% strain, and was capable of real-time monitoring human activities such as finger bending, swallowing, and phonating. Due to these favorable attributes, the graphene/resilin hybrid hydrogel was a promising material for use in wearable sensors. In addition, the above material design and functionalization strategy may provide intriguing opportunities to generate innovative materials for broad applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Carbonized Silk Fabric for Ultrastretchable, Highly Sensitive, and Wearable Strain Sensors
Wang, C., Li, X., Gao, E., Jian, M., Xia, K., Wang, Q., Xu, Z., Ren, T., & Zhang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201601572 · Cited by 916
Jing, X., Mi, H.-Y., Lin, Y.-J., Enriquez, E., Peng, X.-F., & Turng, L.-S. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b06475 · Cited by 492
Cited by
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Naturally sourced hydrogels: emerging fundamental materials for next-generation healthcare sensing
Wang, Z., Wei, H., Huang, Y., Wei, Y., & Chen, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00813k · Cited by 392
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
Highly Stretchable, Adhesive, and Mechanical Zwitterionic Nanocomposite Hydrogel Biomimetic Skin
Yang, B., & Yuan, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14040 · Cited by 189
Gao, Y., Gu, S., Jia, F., & Gao, G. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta07883b · Cited by 159
Metadata
- Authors
- Hu, X., Xia, X.-X., Huang, S.-C., & Qian, Z.-G.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-04-29
- Volume
- 20
- Issue
- 9
- Pages
- 3283-3293
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2943017209
- Cited by
- 88
- References
- 3
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.