Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 492

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Highly Stretchable and Biocompatible Strain Sensors Based on Mussel-Inspired Super-Adhesive Self-Healing Hydrogels for Human Motion Monitoring

Jing, Xin, Mi, Hao-Yang, Lin, Yu-Jyun, Enriquez, Eduardo, Peng, Xiang-Fang, Turng, Lih-Sheng·2018·ACS Applied Materials & Interfaces

Abstract

Integrating multifunctionality such as adhesiveness, stretchability, and self-healing ability on a single hydrogel has been a challenge and is a highly desired development for various applications including electronic skin, wound dressings, and wearable devices. In this study, a novel hydrogel was synthesized by incorporating polydopamine-coated talc (PDA-talc) nanoflakes into a polyacrylamide (PAM) hydrogel inspired by the natural mussel adhesive mechanism. Dopamine molecules were intercalated into talc and oxidized, which enhanced the dispersion of talc and preserved catechol groups in the hydrogel. The resulting dopamine-talc-PAM (DTPAM) hydrogel showed a remarkable stretchability, with over 1000% extension and a recovery rate over 99%. It also displayed strong adhesiveness to various substrates, including human skin, and the adhesion strength surpassed that of commercial double-sided tape and glue sticks, even as the hydrogel dehydrated over time. Moreover, the DTPAM hydrogel could rapidly self-heal and regain its mechanical properties without needing any external stimuli. It showed excellent biocompatibility and improved cell affinity to human fibroblasts compared to the PAM hydrogel. When used as a strain sensor, the DTPAM hydrogel showed high sensitivity, with a gauge factor of 0.693 at 1000% strain, and was capable of monitoring various human motions such as the bending of a finger, knee, or elbow and taking a deep breath. Therefore, this hydrogel displays favorable attributes and is highly suitable for use in human-friendly biological devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.8b06475

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 492

Metadata

Authors
Jing, X., Mi, H.-Y., Lin, Y.-J., Enriquez, E., Peng, X.-F., & Turng, L.-S.
Venue
ACS Applied Materials & Interfaces
Published
2018-06-04
Volume
10
Issue
24
Pages
20897-20909
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2806259909
Cited by
492
References
11
FWCI
22.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Stretchable and Biocompatible Strain Sensors Based on Mussel-Inspired Super-Adhesive Self-Healing Hydrogels for Human Motion Monitoring. https://app.cochat.ai/papers/10.1021/acsami.8b06475
The paper
Jing, X., Mi, H.-Y., Lin, Y.-J., Enriquez, E., Peng, X.-F., & Turng, L.-S. (2018). Highly Stretchable and Biocompatible Strain Sensors Based on Mussel-Inspired Super-Adhesive Self-Healing Hydrogels for Human Motion Monitoring. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b06475

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.