The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
CoxFe3–xO4 Nanocubes for Theranostic Applications: Effect of Cobalt Content and Particle Size
Abstract
We report a facile synthesis of cube-shaped Co x Fe 3– x O 4 nanocrystals (NCs), which could be finely tuned in terms of NC size (from 15 to 27 nm) and cobalt stoichiometry (from 0.1 to 0.7). These particles exhibited high specific absorption rate (SAR) values, relevant for magnetic hyperthermia, and high relaxivity values, significant for magnetic resonance imaging applications. The peculiarity of these NCs is that already at low frequencies (such as 105 kHz, a working frequency used on human patients), they display SAR values that are three-times as large as those of iron oxide nanocubes of comparable sizes (and which were already considered outstanding). The highest SAR value recorded on the NCs reported here (915 ± 10 W/g (Co+Fe) at 105 kHz and 32 kAm –1 ) refers to particles with cubic shape, 20 ± 2 nm edge size, and Co stoichiometry between 0.6 and 0.7. The highest r 2 value (958 mM –1 s –1 ) was instead recorded on nanocubes with Co stoichiometry around 0.5/0.6 and size of 20 ± 2 nm. Remarkably, only at this specific size and Co stoichiometry were the NCs not perfect cubes but had a slightly concave shape, which together with their core–shell structure and magnetic parameters might account for the higher r 2 values recorded. NCs reported here, with optimized SAR and r 2 values, are promising tools for theranostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guardia, P., Di Corato, R., Lartigue, L., Wilhelm, C., Espinosa, A., Garcia-Hernandez, M., Gazeau, F., Manna, L., & Pellegrino, T. (2012) · ACS Nano · doi:10.1021/nn2048137 · Cited by 752
Self-citationA Review of Clinical Translation of Inorganic Nanoparticles
Anselmo, A. C., & Mitragotri, S. (2015) · The AAPS Journal · doi:10.1208/s12248-015-9780-2 · Cited by 509
Smolensky, E. D., Park, H.-Y. E., Zhou, Y., Rolla, G. A., Marjańska, M., Botta, M., & Pierre, V. C. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00369h · Cited by 156
Cited by
Spinels: Controlled Preparation, Oxygen Reduction/Evolution Reaction Application, and Beyond
Zhao, Q., Yan, Z., Chen, C., & Chen, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00051 · Cited by 1,712
Han, X., Ling, X., Wang, Y., Ma, T., Zhong, C., Hu, W., & Deng, Y. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901109 · Cited by 658
Review on magnetic nanoparticles for magnetic nanofluid hyperthermia application
Hedayatnasab, Z., Abnisa, F., & Daud, W. M. A. W. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.03.036 · Cited by 565
Gavilán, H., Avugadda, S. K., Fernández-Cabada, T., Soni, N., Cassani, M., Mai, B. T., Chantrell, R., & Pellegrino, T. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00427a · Cited by 525
Self-citationDesign strategies for shape-controlled magnetic iron oxide nanoparticles
Roca, A. G., Gutiérrez, L., Gavilán, H., Fortes Brollo, M. E., Veintemillas-Verdaguer, S., & Morales, M. D. P. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.008 · Cited by 366
Metadata
- Authors
- Sathya, A., Guardia, P., Brescia, R., Silvestri, N., Pugliese, G., Nitti, S., Manna, L., & Pellegrino, T.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-03-07
- Volume
- 28
- Issue
- 6
- Pages
- 1769-1780
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2271276723
- Cited by
- 180
- References
- 3
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CoxFe3–xO4 Nanocubes for Theranostic Applications: Effect of Cobalt Content and Particle Size. https://app.cochat.ai/papers/10.1021/acs.chemmater.5b04780
- The paper
- Sathya, A., Guardia, P., Brescia, R., Silvestri, N., Pugliese, G., Nitti, S., Manna, L., & Pellegrino, T. (2016). CoxFe3–xO4 Nanocubes for Theranostic Applications: Effect of Cobalt Content and Particle Size. Chemistry of Materials. https://doi.org/10.1021/acs.chemmater.5b04780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.