Synthetic Systems Powered by Biological Molecular Motors
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Biological molecular motors (or biomolecular motors for short) are nature's solution to the efficient conversion of chemical energy to mechanical movement. In biological systems, these fascinating molecules are responsible for movement of molecules, organelles, cells, and whole animals. In engineered systems, these motors can potentially be used to power actuators and engines, shuttle cargo to sensors, and enable new computing paradigms. Here, we review the progress in the past decade in the integration of biomolecular motors into hybrid nanosystems. After briefly introducing the motor proteins kinesin and myosin and their associated cytoskeletal filaments, we review recent work aiming for the integration of these biomolecular motors into actuators, sensors, and computing devices. In some systems, the creation of mechanical work and the processing of information become intertwined at the molecular scale, creating a fascinating type of "active matter". We discuss efforts to optimize biomolecular motor performance, construct new motors combining artificial and biological components, and contrast biomolecular motors with current artificial molecular motors. A recurrent theme in the work of the past decade was the induction and utilization of collective behavior between motile systems powered by biomolecular motors, and we discuss these advances. The exertion of external control over the motile structures powered by biomolecular motors has remained a topic of many studies describing exciting progress. Finally, we review the current limitations and challenges for the construction of hybrid systems powered by biomolecular motors and try to ascertain if there are theoretical performance limits. Engineering with biomolecular motors has the potential to yield commercially viable devices, but it also sharpens our understanding of the design problems solved by evolution in nature. This increased understanding is valuable for synthetic biology and potentially also for medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Promotion of microtubule assembly in vitro by taxol
SCHIFF, P. B., FANT, J., & HORWITZ, S. B. (1979) · Nature · doi:10.1038/277665a0 · Cited by 3,600
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Kinesin superfamily motor proteins and intracellular transport
Hirokawa, N., Noda, Y., Tanaka, Y., & Niwa, S. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2774 · Cited by 1,859
Skeletal muscle: A brief review of structure and function
Frontera, W. R., & Ochala, J. (2015) · Calcified Tissue International · doi:10.1007/s00223-014-9915-y · Cited by 1,758
Single kinesin molecules studied with a molecular force clamp
Visscher, K., Schnitzer, M. J., & Block, S. M. (1999) · Nature · doi:10.1038/22146 · Cited by 1,027
Maze—solving by an amoeboid organism
Nakagaki, T., Yamada, H., & Tóth, Á. (2000) · Nature · doi:10.1038/35035159 · Cited by 1,022
Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965
Bio-inspired magnetic swimming microrobots for biomedical applications
Peyer, K. E., Zhang, L., & Nelson, B. J. (2013) · Nanoscale · doi:10.1039/c2nr32554c · Cited by 820
Energy transduction in the F1 motor of ATP synthase
Wang, H., & Oster, G. (1998) · Nature · doi:10.1038/24409 · Cited by 440
Kinesin׳s tail domain is an inhibitory regulator of the motor domain
Coy, D. L., Hancock, W. O., Wagenbach, M., & Howard, J. (1999) · Nature Cell Biology · doi:10.1038/13001 · Cited by 329
Cited by
The Future of Molecular Machines
Aprahamian, I. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00064 · Cited by 376
Electronic energy migration in microtubules
Kalra, A. P., Benny, A., Travis, S. M., Zizzi, E. A., Morales-Sanchez, A., Oblinsky, D. G., Craddock, T. J. A., Hameroff, S. R., MacIver, M. B., Tuszyński, J. A., et al. (2023) · ACS Central Science · doi:10.1021/acscentsci.2c01114 · Cited by 80
“While the mechanical properties of microtubules and their interaction with molecular machines have been used as key components in transport-based nanodevices, 6 their autofluor-escence has not yet been exploited.”
Cooperative cargo transportation by a swarm of molecular machines
Akter, M., Keya, J. J., Kayano, K., Kabir, A. M. R., Inoue, D., Hess, H., Sada, K., Kuzuya, A., Asanuma, H., & Kakugo, A. (2022) · Science Robotics · doi:10.1126/scirobotics.abm0677 · Cited by 74
Self-citationAll Wired Up: An Exploration of the Electrical Properties of Microtubules and Tubulin
Kalra, A. P., Eakins, B. B., Patel, S. D., Ciniero, G., Rezania, V., Shankar, K., & Tuszynski, J. A. (2020) · ACS Nano · doi:10.1021/acsnano.0c06945 · Cited by 49
Metadata
- Authors
- Saper, G., & Hess, H.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-09-11
- Volume
- 120
- Issue
- 1
- Pages
- 288-309
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2972902458
- Cited by
- 149
- References
- 15
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.