High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index; 8 of the 16 sources its claims cite were checked for support.
Abstract
Combustion of biomass and waste results in release of corrosive species, such as alkali chlorides and water vapor, which accelerate the corrosion of superheaters in the boiler. To improve our understanding of alkali-induced corrosion, long-term corrosion investigations are needed. This study utilizes a systematic approach based on long-term corrosion studies (up to 8000 h) in a well-controlled laboratory environment to understand the corrosion behavior and protectiveness of oxide scales formed on a FeCr alloy (marginal chromia former) and three overlay weld coating systems (lean FeCrAl, FeCrAl, and Ni-based alloy) in a KCl-rich environment at 600 °C. The results show that all the alloys undergo fast breakaway corrosion and form duplex-layered scales consisting of outward- and inward-growing oxide scales. The marginal chromia former exhibits parabolic oxidation kinetics and forms Fe-rich oxides in the outer scale and mixed Fe- and Cr-oxides in the inner layer. These oxide microstructures are compared to the scales formed on probe-exposed samples in boilers, and similar microstructures are typically found after exposures. The FeCrAl coatings form Fe-rich oxides in the outer layer and Fe-, Cr-, and Al-oxides in the inner layer. All alloy systems except the Ni-based coating show corrosion rates in the boiler in good agreement with the laboratory test prediction. The Ni-based coating exhibits the slowest oxidation kinetics in the laboratory, forming thin oxide scales with Ni-rich oxides in the outer layer and Cr-rich oxides in the inner layers, while this is not the case in the waste-fired boiler.
Overview
CoChat Summary
TL;DR
Long-term laboratory and field exposures at 600 °C show that a marginal chromia former and three overlay coatings all undergo breakaway corrosion in KCl-rich biomass/waste boiler-like conditions, forming duplex outward/inward oxide scales. Laboratory parabolic kinetics predict field oxide thickness well for most alloys, except the Ni-based coating, which corrodes faster in the waste-fired boiler due to Cl and high flue-gas temperature.
Key findings
- All investigated materials underwent breakaway oxidation after the shortest laboratory exposure of 168 h at 600 °C in 5% O2 + 20% H2O + N2 with 2 mg/cm² KCl, forming multilayered outward- and inward-growing oxide scales; K2CrO4 particles formed at the surface of all materials.
- Laboratory parabolic rate constants were 0.0256 μm²/s for the marginal chromia former, 0.0216 μm²/s for lean FeCrAl, 0.0149 μm²/s for FeCrAl, and 0.0051 μm²/s for the Ni-based coating. The marginal chromia former grew from ∼90 to ∼206 μm after 168 and 8000 h, while the Ni-based alloy formed 13–42 μm scales after 8000 h.
- After 8000 h, inner-scale Cr enrichment reached 55 at % for lean FeCrAl and 70 at % for FeCrAl; the Ni-based coating had Cr-rich inner scales of 80 at % after 168 h and 90 at % after 8000 h.
- Field oxide thicknesses agreed with laboratory predictions for most alloys: marginal chromia former 150 μm measured vs 148 μm calculated after 3000 h; FeCrAl 70 μm measured vs 69 μm calculated after 3000 h. The Ni-based coating was the exception: 120 μm measured after 1000 h in the waste-fired boiler vs 25 μm calculated, with up to 30% Cl detected within the oxide and 6.5 wt % Cl in the deposit.
Methods
- Four material/coating systems were tested: a marginal chromia former ferritic-martensitic stainless steel, a lean FeCrAl coating with 12.4 wt % Cr, a normal FeCrAl coating with 21 wt % Cr, and a Ni-based coating. Laboratory coupons and field ring samples were produced by overlay welding.
- Laboratory exposures used 2 mg/cm² KCl predeposited on samples, then exposure in 5% O2 + 20% H2O + N2 (balance) at 600 °C for 168, 500, 1000, and 8000 h. Field exposures were at 600 °C in three commercial boilers: marginal chromia former and FeCrAl for 3000 h in a BFB boiler, lean FeCrAl for 2000 h in a wood-chip BFB boiler, and Ni-based alloy for 1000 h in a waste-fired grate boiler.
- Postexposure analysis used SEM/EDX on cross sections prepared by broad ion beam milling, ImageJ oxide thickness measurements, and ion chromatography for Cl⁻ and SO4²⁻ in deposits. Parabolic rate constants were determined from long-term laboratory exposures.
Limitations
- Stated: the study considers the propagation phase and not the initiation phase; the initial phase before 168 h may have a different kp value.
- Stated: field samples can experience changes in flue gas velocity or temperature, thermal cycling, and varying deposit thickness, and outer oxide scale can spall during exposure or handling. For lean FeCrAl in the field, only the inward-growing layer (50 μm) was recovered, so the predicted total thickness was 100 μm.
- Evident from the text: field exposures used different boilers, fuels, and durations for different alloys, so direct laboratory-to-field comparisons across materials are not fully controlled.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
4 Valid · 2 Not valid · 2 Not checked · 40 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“The results of microstructural investigations in this study indicate that the formation of a healing layer is the key to improving corrosion resistance in harsh environments, which is in line with previous studies that have investigated oxide scales formed after breakaway oxidation.30”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Discussion > Oxide Microstructure
What the sources say
- Supportedcites [30] Ssenteza V.; Eklund J.; Bigdeli S.; Jonsson T. Long-Term Corrosion Behavior of FeCr(Al, Ni) Alloys in O2 + H2O with KCl(s) at 600 °C: Microstructural Evolution after Breakaway Oxidation. Corros. Sci. 2024, 226, 111654 10.1016/j.corsci.2023.111654. source
Section 4.3 (p. 11) reports that Cr/Al-rich inward-growing healing layers provide good secondary protection after breakaway oxidation. The Conclusion (p. 12) attributes differences in corrosion resistance mainly to the oxide microstructures formed after breakaway, supporting the cited comparison. (LLM, conf=0.92)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, all alloy systems are expected to undergo fast breakaway oxidation in this very corrosive environment.1,8”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Discussion
What the sources say
- Not checked — no full text of the sourcecites [1] Furugaki T.; Takahashi H.; Hayashi S. Breakdown of Protective Cr-Rich Oxide Scale Formed on Heat-Resistant Steels for Superheater Tubes in a Waste Power Generation Boiler. High Temperature Corrosion of Materials 2024, 101, 61 10.1007/s11085-023-10184-0. source
- Partly supportedcites [8] Reddy L.; Sattari M.; Davis C. J.; Shipway P. H.; Halvarsson M.; Hussain T. Influence of KCl and HCl on a Laser Clad FeCrAl Alloy: In-Situ SEM and Controlled Environment High Temperature Corrosion. Corros. Sci. 2019, 158, 108076 10.1016/j.corsci.2019.07.003. sourceExperimental — accuracy not yet measured
Section 4.2 (page unavailable) reports substantially more corrosion products on the tested APMT FeCrAl coating when KCl is present. It does not establish that all alloy systems will undergo fast breakaway oxidation; the study addresses one coating, and the cited passages do not characterize its oxidation as breakaway. (LLM, conf=0.85)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Thus, the corrosion performance is expected to mainly depend on the secondary protection; i.e., the scale formed after breakaway oxidation.3”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Discussion
What the sources say
- Partly supportedcites [3] Persdotter A.; Eklund J.; Liske J.; Jonsson T. Beyond Breakaway Corrosion–Influence of Chromium, Nickel and Aluminum on Corrosion of Iron-Based Alloys at 600 °C. Corros. Sci. 2020, 177, 108961 10.1016/j.corsci.2020.108961. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) defines secondary protection as the protection provided by the scale formed after breakaway and says alloys in harshly corrosive environments must rely on it. The Conclusions (page unavailable) likewise emphasize its importance where breakaway cannot be prevented. The claim omits that condition and therefore overgeneralizes the paper’s point: primary protection still matters when it can prevent or delay breakaway. (LLM, conf=0.84)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, the combustion of biomass and waste is well-known to result in a corrosive environment within the boiler due to the formation of, e.g., alkali salts and high levels of H2O(g), which accelerate the degradation of various components in the boiler, such as the superheater tubes (SH).1−12”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Introduction
What the sources say
- Not checked — no full text of the sourcecites [1] Furugaki T.; Takahashi H.; Hayashi S. Breakdown of Protective Cr-Rich Oxide Scale Formed on Heat-Resistant Steels for Superheater Tubes in a Waste Power Generation Boiler. High Temperature Corrosion of Materials 2024, 101, 61 10.1007/s11085-023-10184-0. source
- Not checked — no full text of the sourcecites [2] Skrifvars B.-J.; Westén-Karlsson M.; Hupa M.; Salmenoja K. Corrosion of Super-Heater Steel Materials under Alkali Salt Deposits.. Part 2: SEM Analyses of Different Steel Materials. Corros Sci. 2010, 52 (3), 1011– 1019. 10.1016/j.corsci.2009.11.026. source
- Partly supportedcites [3] Persdotter A.; Eklund J.; Liske J.; Jonsson T. Beyond Breakaway Corrosion–Influence of Chromium, Nickel and Aluminum on Corrosion of Iron-Based Alloys at 600 °C. Corros. Sci. 2020, 177, 108961 10.1016/j.corsci.2020.108961. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) identifies corrosion as a problem that limits the lifetime of components in biomass- and waste-fired boilers. The Sample Preparation section (page unavailable) says potassium carbonate can induce breakaway corrosion, but the paper does not establish that combustion produces alkali chlorides and high levels of water vapor or that those species accelerate superheater-tube corrosion. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [4] Jiang C.; Feng M.; Chen M.; Chen K.; Geng S.; Wang F. Corrosion Behaviour of Iron and Nickel Aluminide Coatings under the Synergistic Effect of NaCl and Water Vapour. Corros. Sci. 2021, 187, 109484 10.1016/j.corsci.2021.109484. source
- Partly supportedcites [5] Jafari R.; Sadeghimeresht E.; Farahani T. S.; Huhtakangas M.; Markocsan N.; Joshi S. KCl-Induced High-Temperature Corrosion Behavior of HVAF-Sprayed Ni-Based Coatings in Ambient Air. Journal of Thermal Spray Technology 2018, 27 (3), 500– 511. 10.1007/s11666-017-0684-9. sourceExperimental — accuracy not yet measured
The Introduction of Jafari et al. (2018) clearly supports the chloride half of the claim: combustion of biomass and waste fuels yields high-temperature gases containing chlorine compounds that deposit on the superheater tubes, creating a highly corrosive environment, and 'alkali chloride/chlorine accelerates corrosion by reacting with protective metal oxide scale via the active oxidation mechanism'. However, no passage in our copy attributes corrosion acceleration to water vapor / H2O(g) from combustion — the study was run in dry ambient air at 600 °C, and humidity appears only in the title of a cited reference (Ref 9, Jonsson et al., 'oxidizing humid conditions'), not as a point this paper makes. The H2O(g) element of the citing sentence is therefore not supported by this source. (LLM, conf=0.78)
- Not checked — no full text of the sourcecites [6] Sui J.; Lehmusto J.; Bergelin M.; Hupa M. The Effects of KCl, NaCl and K2CO3 on the High-Temperature Oxidation Onset of Sanicro 28 Steel. Oxidation of Metals 2016, 85 (5), 565– 598. 10.1007/s11085-016-9613-4. source
- Not checked — no full text of the sourcecites [7] Kiamehr S.; Dahl K. v; Montgomery M.; Somers M. A. J. KCl-Induced High Temperature Corrosion of Selected Commercial Alloys. Materials and Corrosion 2015, 66 (12), 1414– 1429. 10.1002/maco.201408213. source
- Partly supportedcites [8] Reddy L.; Sattari M.; Davis C. J.; Shipway P. H.; Halvarsson M.; Hussain T. Influence of KCl and HCl on a Laser Clad FeCrAl Alloy: In-Situ SEM and Controlled Environment High Temperature Corrosion. Corros. Sci. 2019, 158, 108076 10.1016/j.corsci.2019.07.003. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says biomass combustion creates a more aggressive boiler environment that increases material loss, and identifies chloride salts—particularly KCl—as important in biomass fireside corrosion. It also mentions chlorides in municipal-waste boiler deposits and water vapour in a corrosion-related reaction, but does not establish that combustion produces high levels of water vapour or specifically links the resulting degradation to superheater tubes. (LLM, conf=0.84)
- Could not verifycites [9] Okoro S. C.; Kiamehr S.; Montgomery M.; Frandsen F. J.; Pantleon K. Effect of FLue Gas Composition on Deposit Induced Hightemperature Corrosion under Laboratory Conditionsmimicking Biomass FIring. Part I: Exposures in Oxidizingand Chlorinating Atmospheres. Materials and Corrosion 2017, 68 (5), 499– 514. 10.1002/maco.201609173. sourceExperimental — accuracy not yet measured
Our copy of Okoro et al. (2017) holds only the DTU repository record — the title/author header block and the 'Abstract'-labelled metadata and citation-export entries (journal, volume 68, issue 15, pp. 499-514, DOI, RIS/BIBTEX/APA exports) — with no article body text. Six queries (biomass/waste combustion and superheater corrosion, alkali chloride/alkali salt degradation of superheaters, water vapour H2O(g), introduction on biomass-fired boilers, experimental exposure procedures, corrosion-rate/scale results) returned nothing but these metadata passages, so the claim's substance — that biomass and waste combustion releases alkali chlorides and H2O(g) accelerating superheater-tube degradation — is neither stated nor contradicted in our copy. The title's topic (deposit-induced high temperature corrosion mimicking biomass firing) is consistent with the claim but does not assert it, and the record is not flagged truncated, so the decisive text is simply absent rather than cut off. (LLM, conf=0.70)
- Partly supportedcites [10] Wu D. L.; Dahl K. V.; Grumsen F. B.; Christiansen T. L.; Montgomery M.; Hald J. Breakdown Mechanism of γ-Al2O3 on Ni2Al3 Coatings Exposed in a Biomass Fired Power Plant. Corros. Sci. 2020, 170, 108583 10.1016/j.corsci.2020.108583. sourceExperimental — accuracy not yet measured
Our copy of Wu et al. (2020) consists only of the DTU Orbit repository record (Abstract section, no page numbers): it reports a Ni2Al3 coated tube exposed 7100 h in a wood (biomass) firing power plant where local corrosion attack occurred, with γ-Al2O3 broken down by reaction with KCl(g) forming potassium aluminate and Cl migration yielding volatile AlCl3 and alumina fluxing. That supports the part of the claim attributing alkali-chloride-driven corrosion in a biomass-fired boiler to this source. It does not mention water vapour/H2O(g) as a corrosive species, does not mention waste firing, and does not identify the exposed tube as a superheater, so those parts of the background statement are unsupported by our copy (the introduction/body text is not available in our holdings, so the paper's own general background statements could not be checked). (LLM, conf=0.70)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The Ni-based coating exhibits the slowest oxidation kinetics in the laboratory, forming thin oxide scales with Ni-rich oxides in the outer layer and Cr-rich oxides in the inner layers, while this is not the case in the waste-fired boiler.”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
16 more claims
Create a free account to see all 48 claims and every source verdict.
- Borderline: one of the tests for a substantial claim is unclear. 3
- It may state two separate claims as one. 26
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Results > Corrosion Tests in Laboratory Environment
“the measured average oxide thicknesses (μm) are plotted against the square root of exposure time (in seconds), see Figure 1b.”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Results > Corrosion Tests in Laboratory Environment
“According to Figure 1b, which shows the thickness plotted against square of time”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Discussion > Oxide Microstructure
“the protective scale is protected from the alkali-rich environment by the Fe-rich scale formed directly after breakaway oxidation.”
§ High-Temperature Corrosion Behavior of Superheater Materials at 600 °C: Insights from Laboratory and Field Exposures > Results > Corrosion Tests in Laboratory Environment
“According to SEM/EDX analysis, the outer oxides are composed of mainly Ni, while the inner scales are enriched in Cr”
Citations
Cites
Grabke, H. J., Reese, E., & Spiegel, M. (1995) · Corrosion Science · doi:10.1016/0010-938x(95)00011-8 · Cited by 537
KCl Induced Corrosion of a 304-type Austenitic Stainless Steel at 600°C; The Role of Potassium
Pettersson, J., Asteman, H., Svensson, J. E., & Johansson, L. G. (2005) · Oxidation of Metals · doi:10.1007/s11085-005-5704-3 · Cited by 182
Point defects and cation tracer diffusion in (CrFe1 − )3 − O4 spinels
Töpfer, J., Aggarwal, S., & Dieckmann, R. (1995) · Solid State Ionics · doi:10.1016/0167-2738(95)00190-h · Cited by 169
Kawahara, Y. (2007) · Journal of Thermal Spray Technology · doi:10.1007/s11666-006-9012-5 · Cited by 102
Folkeson, N., Jonsson, T., Halvarsson, M., Johansson, L. ‐., & Svensson, J. ‐. (2011) · Materials and Corrosion · doi:10.1002/maco.201005942 · Cited by 93
Self-citationDepletion and Voids Formation in the Substrate During High Temperature Oxidation of Ni–Cr Alloys
Desgranges, C., Lequien, F., Aublant, E., Nastar, M., & Monceau, D. (2013) · Oxidation of Metals · doi:10.1007/s11085-012-9328-0 · Cited by 82
Skrifvars, B.-J., Westén-Karlsson, M., Hupa, M., & Salmenoja, K. (2010) · Corrosion Science · doi:10.1016/j.corsci.2009.11.026 · Cited by 70
Initial Stages of the HCl-Induced High-Temperature Corrosion of Alloy 310
Folkeson, N., Johansson, L.-G., & Svensson, J.-E. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2754174 · Cited by 66
Israelsson, N., Unocic, K. A., Hellström, K., Jonsson, T., Norell, M., Svensson, J.-E., & Johansson, L.-G. (2015) · Oxidation of Metals · doi:10.1007/s11085-015-9546-3 · Cited by 54
Self-citationThermogravimetric studies of high temperature reactions between potassium salts and chromium
Lehmusto, J., Lindberg, D., Yrjas, P., Skrifvars, B.-J., & Hupa, M. M. (2012) · Corrosion Science · doi:10.1016/j.corsci.2012.02.013 · Cited by 53
Failure analysis of superheater tube
Movahedi-Rad, A. V., Plasseyed, S. S., & Attarian, M. (2014) · Engineering Failure Analysis · doi:10.1016/j.engfailanal.2014.11.012 · Cited by 46
Persdotter, A., Eklund, J., Liske, J., & Jonsson, T. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108961 · Cited by 44
Self-citationJiang, C., Feng, M., Chen, M., Chen, K., Geng, S., & Wang, F. (2021) · Corrosion Science · doi:10.1016/j.corsci.2021.109484 · Cited by 42
KCl‐induced high temperature corrosion of selected commercial alloys: Part I: chromia‐formers
Kiamehr, S., Dahl, K. V., Montgomery, M., & Somers, M. A. J. (2015) · Materials and Corrosion · doi:10.1002/maco.201408213 · Cited by 42
Pettersson, C., Johansson, L.-G., & Svensson, J.-E. (2008) · Oxidation of Metals · doi:10.1007/s11085-008-9118-x · Cited by 40
Phother-Simon, J., Hanif, I., Liske, J., & Jonsson, T. (2021) · Corrosion Science · doi:10.1016/j.corsci.2021.109315 · Cited by 37
Self-citationKCl-Induced High-Temperature Corrosion Behavior of HVAF-Sprayed Ni-Based Coatings in Ambient Air
Jafari, R., Sadeghimeresht, E., Farahani, T. S., Huhtakangas, M., Markocsan, N., & Joshi, S. (2018) · Journal of Thermal Spray Technology · doi:10.1007/s11666-017-0684-9 · Cited by 37
Waste incineration plants in the FRG: Construction, materials, investigation on cases of corrosion
Reichel, H. ‐., & Schirmer, U. (1989) · Materials and Corrosion · doi:10.1002/maco.19890400303 · Cited by 37
The Influence of Sulfur Additions on the Corrosive Environments in a Waste-Fired CFB Boiler
Pettersson, J., Pettersson, C., Folkeson, N., Johansson, L. G., Skog, E., & Svensson, J. E. (2006) · Materials Science Forum · doi:10.4028/www.scientific.net/msf.522-523.563 · Cited by 31
Yan, Z., Li, W., Li, X., Wei, J., Liu, C., & Da, Y. (2022) · Engineering Failure Analysis · doi:10.1016/j.engfailanal.2022.106457 · Cited by 31
Reddy, L., Sattari, M., Davis, C. J., Shipway, P. H., Halvarsson, M., & Hussain, T. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.07.003 · Cited by 28
Okoro, S. C., Kiamehr, S., Montgomery, M., Frandsen, F. J., & Pantleon, K. (2017) · Materials and Corrosion · doi:10.1002/maco.201609173 · Cited by 27
Continuous KCl addition in high temperature exposures of 304 L – A way to mimic a boiler environment
Phother-Simon, J., Jonsson, T., & Liske, J. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108511 · Cited by 25
Self-citationEklund, J., Persdotter, A., Hanif, I., Bigdeli, S., & Jonsson, T. (2021) · Corrosion Science · doi:10.1016/j.corsci.2021.109584 · Cited by 23
Self-citationSsenteza, V., Eklund, J., Bigdeli, S., & Jonsson, T. (2024) · Corrosion Science · doi:10.1016/j.corsci.2023.111654 · Cited by 23
Self-citationRecent Development of Corrosion Factors and Coating Applications in Biomass Firing Plants
Wu, D., Yuan, Z., Liu, S., Zheng, J., Wei, X., & Zhang, C. (2020) · Coatings · doi:10.3390/coatings10101001 · Cited by 22
The Effects of KCl, NaCl and K2CO3 on the High-Temperature Oxidation Onset of Sanicro 28 Steel
Sui, J., Lehmusto, J., Bergelin, M., & Hupa, M. (2016) · Oxidation of Metals · doi:10.1007/s11085-016-9613-4 · Cited by 19
Fireside corrosion in German fossil‐fuel fired power plants. Appearence, mechanism and causes
Reichel, H. (1988) · Materials and Corrosion · doi:10.1002/maco.19880390205 · Cited by 18
High temperature corrosion memory in a waste fired boiler – Influence of sulfur
Paz, M. D., Phother-Simon, J., Andersson, S., & Jonsson, T. (2021) · Waste Management · doi:10.1016/j.wasman.2021.05.005 · Cited by 17
Self-citationBreakdown mechanism of γ-Al2O3 on Ni2Al3 coatings exposed in a biomass fired power plant
Wu, D. L., Dahl, K. V., Grumsen, F. B., Christiansen, T. L., Montgomery, M., & Hald, J. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108583 · Cited by 16
The effect of Cl, Br, and F on high-temperature corrosion of heat-transfer alloys
Eriksson, J.-E., Lehmusto, J., Dirbeba, M., Silvander, L., Lindberg, D., & Hupa, L. (2023) · Fuel · doi:10.1016/j.fuel.2023.128516 · Cited by 15
The Onset of Potassium Chloride Induced High Temperature Corrosion: A Novel Experimental Approach
Sui, J., Lehmusto, J., Bergelin, M., & Hupa, M. M. (2014) · Oxidation of Metals · doi:10.1007/s11085-014-9501-8 · Cited by 15
Should the oxygen source be considered in the initiation of KCl-induced high-temperature corrosion?
Lehmusto, J., Sattari, M., Halvarsson, M., & Hupa, L. (2021) · Corrosion Science · doi:10.1016/j.corsci.2021.109332 · Cited by 11
Chlorine Corrosion Degradation of Low Alloyed Ferritic Steels in Temperature Range 450–550 °C
Dudziak, T. P., Jura, K., & Rutkowska, J. (2016) · Oxidation of Metals · doi:10.1007/s11085-016-9617-0 · Cited by 8
Improving Heat Recovery In Biomass-Fired Boilers
Keiser, J. R., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Sharp, W., Singbeil, D., Singh, P., Frederick, L. A., & Meyer, J. (2013) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1093743 · Cited by 7
Initial corrosion attack of 304L and T22 in 2 MW biomass gasifier: a microstructural investigation
Hooshyar, H., Liske, J., Johansson, L., Seemann, M. C., & Jonsson, T. (2015) · Materials at High Temperatures · doi:10.1179/0960340914z.000000000101 · Cited by 5
Self-citationFurugaki, T., Takahashi, H., & Hayashi, S. (2024) · High Temperature Corrosion of Materials · doi:10.1007/s11085-023-10184-0 · Cited by 4
Research works printed but not linked: 3
- Mcnallan M.; Liang W. W.; Kim S. H.; Kang C. T. Acceleration of the High Temperature Oxidation of Metals by Chlorine. NACE 1983, 316– 321.
- Grabke H. J.; Reese E.; Spiegel M. The Effects of Chlorides, Hydrogen Chloride, and Sulfur Dioxide in the Oxidation of Steels below Deposits. Corrosion Sci. 1995, 37 (7), 1023– 1043. 10.1016/0010-938X(95)00011-8. · DOI · Paper page
- Folkeson N.; Jonsson T.; Halvarsson M.; Johansson L.-G.; Svensson J.-E. The Influence of Small Amounts of KCl(s) on the High Temperature Corrosion of a Fe-2.25Cr-1Mo Steel at 400 and 500°C. Materials and Corrosion 2011, 62 (7), 606– 615. 10.1002/maco.201005942. · DOI · Paper page
Cited by
Yang, J. Y., Ren, P., Zhang, P., Yang, Y., & Wang, Q. J. (2026) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2026.133562 · Cited by 1
Metadata
- Authors
- Ssenteza, V., Olausson, M. D. P., Eklund, J., Nockert, J., Liske, J., & Jonsson, T.
- Affiliations
- Chalmers University of Technology (SE)
- Chalmers University of Technology, Kemivägen 10, 412 96 Gothenburg, Sweden
- Valmet (Sweden) (SE)
- Kanthal (Sweden) (SE)
- Corresponding author
- Ssenteza, Vicent
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2024-12-12
- Volume
- 39
- Issue
- 1
- Pages
- 819-827
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- PMC
- PMC11726439
- OpenAlex
- W4405307976
- Semantic Scholar
- 9ea7e2252499f245645b92aa75e9f881fb980560
- Cited by
- 1
- References
- 38
- Citations by year
- 2026: 1
- FWCI
- 0.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Energy & Fuels (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Funders
- H2020 Energy (815147)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › High-Temperature Coating Behaviors
- Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
- Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
- Keywords
- high-temperature corrosion, oxide scale formation, breakaway corrosion, oxidation kinetics, boiler corrosion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.