Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index; none of the 48 sources its claims cite is checked for support yet.

Isotopically Labeled Nanoparticles at Relevant Concentrations: How Low Can We Go? The Case of CdSe/ZnS QDs in Surface Waters

Open access

Abstract

Analytical barriers impose work at nanoparticles (NPs) concentrations orders of magnitude higher than the expected NPs concentrations in the environment. To overcome these limitations, the use of nontraditional stable isotope tracers incorporated in NPs (spiked-NPs) coupled with HR-ICP-MS has been proposed. The performance and efficiency of this analytical method was assessed in the case of quantum dots (QDs). Multi-isotopically labeled 111 Cd 77 Se/ 68 ZnS QDs were synthesized and their dissemination in natural aquatic matrices (river, estuarine and sea waters) was modeled at very low concentrations (from 0.1 to 5000 ppt). The QD limits of quantification (QD-LOQ) in each matrix were calculated according to the isotopic tracer. In ultrapure and simple medium (HNO 3 2%), Zn, Cd, and Se originated from the QDs were quantifiable at concentrations of 10, 0.3, and 6 ppt, respectively, which are lower than the conventional HR-ICP-MS LOQs. In aquatic matrices, the QD-LOQs increase 10-, 130-, and 250-fold for Zn, Cd, and Se, respectively, but remain relevant of environmental concentrations (3.4 ppt ≤ QD-LOQs ≤ 2.5 ppb). These results validate the use of isotopically labeled ENPs at relevant concentrations in experimental studies related to either their fate, behavior, or toxicity in most aquatic matrices.

Overview

CoChat Summary

TL;DR

The paper determines how low isotopically labeled CdSe/ZnS quantum dots can be quantified in river, estuarine, and seawater matrices by HR-ICP-MS. It reports QD limits of quantification from 3.4 to 2500 ppt depending on tracer element and matrix, with Cd and Zn tracers performing far better than Se.

Key findings

  • Multi-spiked CdSe/ZnS QDs were synthesized with 95.89% ¹¹¹Cd, 99.11% ⁶⁸Zn, and 98.95% ⁷⁷Se enrichments; TEM size was 7.9 ± 1.1 nm (n = 250), and the TGA-coated stock contained 101.1 ± 1.0 ppm Zn, 31.8 ± 0.3 ppm Cd, 19.2 ± 0.3 ppm Se, and 404 ± 41 ppm S by ICP-OES.
  • Recovery rates were 99 ± 14% for Cd, 97 ± 13% for Zn, and 19 ± 8% for Se across all matrices; Se performed poorly because it required high-resolution ICP-MS and gave much lower count numbers.
  • QD-LOQs in simple media were 10 and 7 ppt for Zn, 0.31 and 1.9 ppt for Cd, and 6 ppt for Se in HNO₃ 2%; in complex matrices they rose to 39–139 ppt for Zn, 3.4–76 ppt for Cd, and 132–2534 ppt for Se. Mean QD-LOQs for Cd and Zn were 29 and 70 ppt, and complex matrices gave QD-LOQs 37 and 11 times those in simple media for Cd and Zn, respectively.
  • The method allowed detection in realistic surface waters at about 41 ppt Cd and 95 ppt Zn on average, 3–6 orders of magnitude lower than typical ENP fate/toxicity study concentrations, and up to 2 orders of magnitude more sensitive than QD photoluminescence methods.

Methods

  • Multi-isotopically labeled CdSe/ZnS QDs were synthesized by a hot-injection adaptation of Bae et al., using ¹¹¹Cd-enriched CdO, ⁶⁸Zn-enriched ZnO, ⁷⁷Se-enriched Se, and sulfur, then ligand-exchanged with thioglycolic acid; characterization used UV-vis, fluorescence, TEM/EDXS, and ICP-OES.
  • QDs were added to Seine river water, synthetic seawater, three Seine/SW estuarine mixtures, and controls (HNO₃ 2% and NaNO₃ 0.01 M) at target concentrations of 0.1–5000 ppt Zn, corresponding to 0.03–1500 ppt Cd and 0.02–1000 ppt Se; samples were triplicated, acidified to 2% HNO₃, and seawater/estuarine samples were diluted 50-fold before analysis.
  • Quantification used HR-ICP-MS for Cd, Zn, and Se isotopes with Rh internal standard and isobaric interference corrections; recovery plots, RMSEP, t-tests, and ANOVA were used to determine QD-LOQs and assess controlling factors.

Limitations

  • The paper states that Se tracing lacks sensitivity: recovery was only 19 ± 8%, QD-LOQSe was about one order of magnitude higher than QD-LOQZn and QD-LOQCd, and for elements subject to strong polyatomic interferences it may not be possible to access spike concentrations below the ppb level; hydride generation is suggested as a possible workaround.
  • The paper states that QD-LOQs in complex matrices depend on geochemical background concentration, dilution factor, and analysis resolution; Zn QD-LOQ depended only on dilution factor, while Cd QD-LOQ correlated strongly with geochemical background.
  • The paper states that QD-LOQ estimates are conservative/overestimated because few experimental points lie near the LOQ and RMSEP is calculated from data spanning several decades; it also notes that aggregation means not all disseminated QDs will dissolve. Evident from the text: the seawater matrix was synthetic rather than natural, and only one natural river water (Seine) was tested.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1021/acs.est.8b04096

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 2 Not valid · 28 Not checked · 69 Own results and interpretations

49 more claims

Create a free account to see all 99 claims and to verify the 43 references still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 27
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 55 references

Research works printed but not linked: 2

  1. McCurdy E., 2014, Spectroscopy
  2. Thomas R., 2002, Spectroscopy, 17

Cited by

See all 27

Metadata

Authors
Supiandi, N. I., Charron, G., Tharaud, M., Cordier, L., Guigner, J.-M., Benedetti, M. F., & Sivry, Y.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • Sorbonne Paris Cité (FR)
  • Institut de minéralogie, de physique des matériaux et de cosmochimie (FR)
Corresponding author
Sivry, Y.
Venue
Environmental Science & Technology
Published
2019-01-31
Volume
53
Issue
5
Pages
2586-2594
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2913316496
Cited by
27
References
55
Citations by year
2024: 3 · 2023: 2 · 2022: 8 · 2021: 5 · 2020: 5 · 2019: 4
FWCI
2.26
Type
journal article
Language
en
Locations
  • Environmental Science & Technology (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
  • Institut de Physique du Globe de Paris
  • R?gion ?le-de-France (12015908)
  • Agence Nationale de S?curit? Sanitaire de l'Alimentation, de l'Environnement et du Travail (EST-2013/1/264)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
  • Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
Keywords
CdSe/ZnS quantum dots, stable isotope tracers, limit of quantification, river water, estuarine waters, seawater, nanoparticle toxicity
MeSH terms
Sulfides, Zinc Compounds, Selenium Compounds, Cadmium Compounds, Quantum Dots

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.