The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Luminescent Zn(II) Coordination Polymers for Highly Selective Sensing of Cr(III) and Cr(VI) in Water
Abstract
Three photoluminescent zinc coordination polymers (CPs), {[Zn 2 (tpeb) 2 (2,5-tdc)(2,5-Htdc) 2 ]·2H 2 O} n ( 1 ), {[Zn 2 (tpeb) 2 (1,4-ndc)(1,4-Hndc) 2 ]·2.6H 2 O} n ( 2 ), and {[Zn 2 (tpeb) 2 (2,3-ndc) 2 ]·H 2 O} n ( 3 ) (tpeb = 1,3,5-tri-4-pyridyl-1,2-ethenylbenzene, 2,5-tdc = 2,5-thiophenedicarboxylic acid, 1,4-ndc = 1,4-naphthalenedicarboxylic acid, and 2,3-ndc = 2,3-naphthalenedicarboxylic acid) were prepared from reactions of Zn(NO 3 ) 2 ·6H 2 O with tpeb and 2,5-H 2 tdc, 1,4-H 2 ndc, or 2,3-H 2 ndc under solvothermal conditions. Compound 1 has a two-dimensional (2D) grid-like network formed from bridging 1D [Zn(tpeb)] n chains via 2,5-tdc dianions. 2 and 3 possess similar one-dimensional (1D) double-chain structures derived from bridging the [Zn(tpeb)] n chains via pairs of 1,4-ndc or 2,3-ndc ligands. The solid-state, visible emission by 1 – 3 was quenched by Cr 3+, CrO 4 2–, and Cr 2 O 7 2– ions in water with detection limits by the most responsive complex 3 of 0.88 ppb for Cr 3+ and 2.623 ppb for Cr 2 O 7 2– (pH = 3) or 1.734 ppb for CrO 4 2– (pH = 12). These values are well below the permissible limits set by the USEPA and European Union and the lowest so far reported for any bi/trifunctional CPs sensors. The mechanism of Cr 3+ luminescence quenching involves irreversible coordination to free pyridyl sites in the CP framework, while the Cr 6+ quenching involves reversible overlap of the absorption bands of the analytes with those of the excitation and/or emission bands for 3 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystal structure refinement with SHELXL
Sheldrick, G. M. (2015) · Acta Crystallographica Section C Structural Chemistry · doi:10.1107/s2053229614024218 · Cited by 43,982
Single-crystal structure validation with the program PLATON
Spek, A. L. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889802022112 · Cited by 14,084
An empirical correction for absorption anisotropy
Blessing, R. H. (1995) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767394005726 · Cited by 7,928
Luminescent Functional Metal–Organic Frameworks
Cui, Y., Yue, Y., Qian, G., & Chen, B. (2012) · Chemical Reviews · doi:10.1021/cr200101d · Cited by 5,697
Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576714022985 · Cited by 4,983
Luminescent metal–organic frameworks
Allendorf, M. D., Bauer, C. A., Bhakta, R. K., & Houk, R. J. T. (2009) · Chemical Society Reviews · doi:10.1039/b802352m · Cited by 4,960
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Wang, B., Lv, X.-L., Feng, D., Xie, L.-H., Zhang, J., Li, M., Xie, Y., Li, J.-R., & Zhou, H.-C. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b01663 · Cited by 1,568
Optical chemosensors and reagents to detect explosives
Salinas, Y., Martínez-Máñez, R., Marcos, M. D., Sancenón, F., Costero, A. M., Parra, M., & Gil, S. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15173h · Cited by 1,144
Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection
Chang, H., Tang, L., Wang, Y., Jiang, J., & Li, J. (2010) · Analytical Chemistry · doi:10.1021/ac9025384 · Cited by 892
Cited by
Metal ion detection using luminescent-MOFs: Principles, strategies and roadmap
Razavi, S. A. A., & Morsali, A. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213299 · Cited by 262
Tian, X.-M., Yao, S.-L., Qiu, C.-Q., Zheng, T.-F., Chen, Y.-Q., Huang, H., Chen, J.-L., Liu, S.-J., & Wen, H.-R. (2020) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.9b03152 · Cited by 261
Metadata
- Authors
- Gu, T.-Y., Dai, M., Young, D. J., Ren, Z.-G., & Lang, J.-P.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-24
- Volume
- 56
- Issue
- 8
- Pages
- 4668-4678
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2598797895
- Cited by
- 254
- References
- 39
- FWCI
- 13.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Luminescent Zn(II) Coordination Polymers for Highly Selective Sensing of Cr(III) and Cr(VI) in Water. https://app.cochat.ai/papers/10.1021/acs.inorgchem.7b00311
- The paper
- Gu, T.-Y., Dai, M., Young, D. J., Ren, Z.-G., & Lang, J.-P. (2017). Luminescent Zn(II) Coordination Polymers for Highly Selective Sensing of Cr(III) and Cr(VI) in Water. Inorganic Chemistry. https://doi.org/10.1021/acs.inorgchem.7b00311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.