The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Luminescent Zn(II) Coordination Polymers for Highly Selective Sensing of Cr(III) and Cr(VI) in Water
Abstract
Three photoluminescent zinc coordination polymers (CPs), {[Zn 2 (tpeb) 2 (2,5-tdc)(2,5-Htdc) 2 ]·2H 2 O} n ( 1 ), {[Zn 2 (tpeb) 2 (1,4-ndc)(1,4-Hndc) 2 ]·2.6H 2 O} n ( 2 ), and {[Zn 2 (tpeb) 2 (2,3-ndc) 2 ]·H 2 O} n ( 3 ) (tpeb = 1,3,5-tri-4-pyridyl-1,2-ethenylbenzene, 2,5-tdc = 2,5-thiophenedicarboxylic acid, 1,4-ndc = 1,4-naphthalenedicarboxylic acid, and 2,3-ndc = 2,3-naphthalenedicarboxylic acid) were prepared from reactions of Zn(NO 3 ) 2 ·6H 2 O with tpeb and 2,5-H 2 tdc, 1,4-H 2 ndc, or 2,3-H 2 ndc under solvothermal conditions. Compound 1 has a two-dimensional (2D) grid-like network formed from bridging 1D [Zn(tpeb)] n chains via 2,5-tdc dianions. 2 and 3 possess similar one-dimensional (1D) double-chain structures derived from bridging the [Zn(tpeb)] n chains via pairs of 1,4-ndc or 2,3-ndc ligands. The solid-state, visible emission by 1 – 3 was quenched by Cr 3+, CrO 4 2–, and Cr 2 O 7 2– ions in water with detection limits by the most responsive complex 3 of 0.88 ppb for Cr 3+ and 2.623 ppb for Cr 2 O 7 2– (pH = 3) or 1.734 ppb for CrO 4 2– (pH = 12). These values are well below the permissible limits set by the USEPA and European Union and the lowest so far reported for any bi/trifunctional CPs sensors. The mechanism of Cr 3+ luminescence quenching involves irreversible coordination to free pyridyl sites in the CP framework, while the Cr 6+ quenching involves reversible overlap of the absorption bands of the analytes with those of the excitation and/or emission bands for 3 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystal structure refinement with SHELXL
Sheldrick, G. M. (2015) · Acta Crystallographica Section C Structural Chemistry · doi:10.1107/s2053229614024218 · Cited by 43,982
Single-crystal structure validation with the program PLATON
Spek, A. L. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889802022112 · Cited by 14,084
An empirical correction for absorption anisotropy
Blessing, R. H. (1995) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767394005726 · Cited by 7,928
Luminescent Functional Metal–Organic Frameworks
Cui, Y., Yue, Y., Qian, G., & Chen, B. (2012) · Chemical Reviews · doi:10.1021/cr200101d · Cited by 5,697
Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576714022985 · Cited by 4,983
Luminescent metal–organic frameworks
Allendorf, M. D., Bauer, C. A., Bhakta, R. K., & Houk, R. J. T. (2009) · Chemical Society Reviews · doi:10.1039/b802352m · Cited by 4,960
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Wang, B., Lv, X.-L., Feng, D., Xie, L.-H., Zhang, J., Li, M., Xie, Y., Li, J.-R., & Zhou, H.-C. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b01663 · Cited by 1,568
Optical chemosensors and reagents to detect explosives
Salinas, Y., Martínez-Máñez, R., Marcos, M. D., Sancenón, F., Costero, A. M., Parra, M., & Gil, S. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15173h · Cited by 1,144
Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection
Chang, H., Tang, L., Wang, Y., Jiang, J., & Li, J. (2010) · Analytical Chemistry · doi:10.1021/ac9025384 · Cited by 892
Efficient Activation of Aromatic C-H Bonds for Addition to C-C Multiple Bonds
Jia, C., Piao, D., Oyamada, J., Lu, W., Kitamura, T., & Fujiwara, Y. (2000) · Science · doi:10.1126/science.287.5460.1992 · Cited by 827
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Zheng, M., Xie, Z., Qu, D., Li, D., Du, P., Jing, X., & Sun, Z. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4042355 · Cited by 794
Zhou, L., Lin, Y., Huang, Z., Ren, J., & Qu, X. (2012) · Chem. Commun. · doi:10.1039/c2cc16791c · Cited by 706
Tuning the Selectivity of Two Chemosensors to Fe(III) and Cr(III)
Mao, J., Wang, L., Dou, W., Tang, X., Yan, Y., & Liu, W. (2007) · Organic Letters · doi:10.1021/ol7020687 · Cited by 380
Li, X., Xu, H., Kong, F., & Wang, R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201307650 · Cited by 349
Sperling, M., Xu, S., & Welz, B. (1992) · Analytical Chemistry · doi:10.1021/ac00048a007 · Cited by 343
MOF based luminescence tuning and chemical/physical sensing
Müller-Buschbaum, K., Beuerle, F., & Feldmann, C. (2015) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2015.03.036 · Cited by 337
Luminescent Silole Nanoparticles as Chemoselective Sensors for Cr(VI)
Toal, S. J., Jones, K. A., Magde, D., & Trogler, W. C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052582w · Cited by 328
Highly Selective Detection of Nitro Explosives by a Luminescent Metal–Organic Framework
Nagarkar, S. S., Joarder, B., Chaudhari, A. K., Mukherjee, S., & Ghosh, S. K. (2013) · Angewandte Chemie · doi:10.1002/ange.201208885 · Cited by 279
Shi, P.-F., Zhao, B., Xiong, G., Hou, Y.-L., & Cheng, P. (2012) · Chemical Communications · doi:10.1039/c2cc33707j · Cited by 247
Linos, A., Petralias, A., Christophi, C. A., Christoforidou, E., Kouroutou, P., Stoltidis, M., Veloudaki, A., Tzala, E., Makris, K. C., & Karagas, M. R. (2011) · Environmental Health · doi:10.1186/1476-069x-10-50 · Cited by 246
Yi, F., Li, J., Wu, D., & Sun, Z. (2015) · Chemistry – A European Journal · doi:10.1002/chem.201500595 · Cited by 235
Park, I., Medishetty, R., Kim, J., Lee, S. S., & Vittal, J. J. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201310536 · Cited by 182
Subramanian, K. S. (1988) · Analytical Chemistry · doi:10.1021/ac00152a004 · Cited by 172
Narin, İ., Kars, A., & Soylak, M. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.04.125 · Cited by 141
Cao, C., Hu, H., Xu, H., Qiao, W., & Zhao, B. (2016) · CrystEngComm · doi:10.1039/c5ce02568k · Cited by 132
Kiran, K., Kumar, K. S., Prasad, B., Kanchi, S., Babu, L. R., & Janardhanam, K. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.05.007 · Cited by 126
Zhitkovich, A., Song, Y., Quievryn, G., & Voitkun, V. (2000) · Biochemistry · doi:10.1021/bi0015459 · Cited by 115
Jena, B. K., & Raj, C. R. (2008) · Talanta · doi:10.1016/j.talanta.2008.02.027 · Cited by 110
The role of chromium(V) in the mechanism of chromate-induced oxidative DNA damage and cancer.
Sugden, K. D., & Stearns, D. M. (2000) · PubMed · Cited by 103
Oxygen radical-mediated DNA damage by redox-active chromium(III) complexes
Sugden, K. D., Geer, R. D., & Rogers, S. J. (1992) · Biochemistry · doi:10.1021/bi00161a049 · Cited by 97
Saluja, P., Sharma, H. K., Kaur, N., Singh, N., & Jang, D. O. (2012) · Tetrahedron · doi:10.1016/j.tet.2012.01.047 · Cited by 93
Demirel, G. B., Daglar, B., & Bayındır, M. (2013) · Chemical Communications · doi:10.1039/c3cc43202e · Cited by 88
Gürleyük, H., & Wallschläger, D. (2001) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b102740a · Cited by 88
Chen, M., Chen, L., Li, H., Brammer, L., & Lang, J. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c6qi00160b · Cited by 55
Self-citationKubáň, P., Kuban, P., & Kubáň, V. (2003) · Electrophoresis · doi:10.1002/elps.200390179 · Cited by 54
An ‘off–on’ fluorescent chemosensor of selectivity to Cr3+ and its application to MCF-7 cells
Li, Z., Zhao, W., Zhang, Y., Zhang, L., Yu, M., Liu, J., & Zhang, H. (2011) · Tetrahedron · doi:10.1016/j.tet.2011.07.008 · Cited by 45
Polymers for Luminescent Sensing Applications
Kim, H., Kim, Y., & Chang, J. Y. (2014) · Macromolecular Chemistry and Physics · doi:10.1002/macp.201400128 · Cited by 31
Cited by
Metal ion detection using luminescent-MOFs: Principles, strategies and roadmap
Razavi, S. A. A., & Morsali, A. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213299 · Cited by 262
Tian, X.-M., Yao, S.-L., Qiu, C.-Q., Zheng, T.-F., Chen, Y.-Q., Huang, H., Chen, J.-L., Liu, S.-J., & Wen, H.-R. (2020) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.9b03152 · Cited by 261
Metadata
- Authors
- Gu, T.-Y., Dai, M., Young, D. J., Ren, Z.-G., & Lang, J.-P.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-24
- Volume
- 56
- Issue
- 8
- Pages
- 4668-4678
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2598797895
- Cited by
- 254
- References
- 39
- FWCI
- 13.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.