CoChat

Data-Driven Approaches Can Overcome the Cost–Accuracy Trade-Off in Multireference Diagnostics

Open access
Duan, Chenru, Liu, Fang, Nandy, Aditya, Kulik, Heather J. · 2020 · Journal of Chemical Theory and Computation
Cited by 47

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

High-throughput computational screening typically employs methods (i.e., density functional theory or DFT) that can fail to describe challenging molecules, such as those with strongly correlated electronic structure. In such cases, multireference (MR) correlated wavefunction theory (WFT) would be the appropriate choice but remains more challenging to carry out and automate than single-reference (SR) WFT or DFT. Numerous diagnostics have been proposed for identifying when MR character is likely to have an effect on the predictive power of SR calculations, but conflicting conclusions about diagnostic performance have been reached on small data sets. We compute 15 MR diagnostics, ranging from affordable DFT-based to more costly MR-WFT-based diagnostics, on a set of 3,165 equilibrium and distorted small organic molecules containing up to six heavy atoms. Conflicting MR character assignments and low pairwise linear correlations among diagnostics are also observed over this set. We evaluate the ability of existing diagnostics to predict the percent recovery of the correlation energy, %Ecorr. None of the DFT-based diagnostics are nearly as predictive of %Ecorr as the best WFT-based diagnostics. To overcome the limitation of this cost–accuracy trade-off, we develop machine learning (ML, i.e., kernel ridge regression) models to predict WFT-based diagnostics from a combination of DFT-based diagnostics and a new, size-independent 3D geometric representation. The ML-predicted diagnostics correlate as well with MR effects as their computed (i.e., with WFT) values, significantly improving over the DFT-based diagnostics on which the models were trained. These ML models thus provide a promising approach to improve upon DFT-based diagnostic accuracy while remaining suitably low cost for high-throughput screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jctc.0c00358

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
Duan, C., Liu, F., Nandy, A., & Kulik, H. J.
Venue
Journal of Chemical Theory and Computation
Published
2020-06-14
Volume
16
Issue
7
Pages
4373-4387
ISSN
  • 1549-9618 (ISSN-L)
  • 1549-9626
OpenAlex
W3034944909
Cited by
47
References
19
FWCI
3.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.