The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Blood-Compatible Surfaces with Phosphorylcholine-Based Polymers for Cardiovascular Medical Devices
Abstract
For the acquisition of blood-compatible materials, various hydrophilic polymers for surface modification have been examined. Among them, polymers with a representative phospholipid polar group, the phosphorylcholine (PC) group, are a successful example. These polymers were designed from inspiration of the cell membrane surface and provide protein adsorption resistance even following contact with plasma. This important property is based on the unique hydration state of water molecules surrounding hydrated polymer; in other words, water molecules weakly interact with the polymers and maintain their favorable cluster structure through hydrogen bonding. These polymers are not only hydrophilic, but also electrically neutral, important characteristics which make hydrogen bonding with water molecules less likely to occur and avoid hydrophobic interactions. Phosphorylcholine groups and other zwitterionic structures are significant as hydrophilic functional groups meeting these important requirements. In this review, blood compatibility of a polymer having a PC group is introduced in relation to its hydration structure, followed by a description of the applications of this polymer to cardiovascular medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Novel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Cited by
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Metadata
- Authors
- Ishihara, K.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-07-30
- Volume
- 35
- Issue
- 5
- Pages
- 1778-1787
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2887036209
- Cited by
- 187
- References
- 4
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood-Compatible Surfaces with Phosphorylcholine-Based Polymers for Cardiovascular Medical Devices. https://app.cochat.ai/papers/10.1021/acs.langmuir.8b01565
- The paper
- Ishihara, K. (2019). Blood-Compatible Surfaces with Phosphorylcholine-Based Polymers for Cardiovascular Medical Devices. Langmuir. https://doi.org/10.1021/acs.langmuir.8b01565
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.