Multiscale Framework for Imaging Radiolabeled Therapeutics
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The resistance of a tumor to a drug is the result of bulk properties of the tumor tissue as well as phenotypic variations displayed by single cells. Here, we show that radioisotopic detection methods, commonly used for tracking the tissue distribution of drug compounds, can be extended to the single-cell level to image the same molecule over a range of physical scales. The anticancer drug rituximab was labeled with short-lived radionuclides (89Zr/64Cu) and its accumulation at the organ level was imaged using PET in a humanized transgenic mouse model of non-Hodgkin’s lymphoma. To capture the distribution of the drug at a finer scale, tissue sections and single living cells were imaged using radioluminescence microscopy (RLM), a novel method that can detect radionuclides with single-cell resolution. In vivo PET images (24 h postinjection) showed that [89Zr]rituximab targeted the intended site of human CD20 expression, the spleen. Within this organ, RLM was used to resolve radiotracer accumulation in the splenic red pulp. In a separate study, RLM highlighted marked differences between single cells, with binding of the radiolabeled antibody ranging from background levels to 1200 radionuclides per cell. Overall, RLM images demonstrated significantly higher spatial resolution and sensitivity than conventional storage-phosphor autoradiography. In conclusion, this combination of PET and RLM provides a unique opportunity for exploring the molecular mechanism of drugs by tracking the same molecule over multiple physical scales, ranging from single living cells to organs substructures and entire living subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These approaches are complemented by in vivo imaging techniques such as radioluminescence microscopy (RLM), which detects radiolabeled drugs at single-cell resolution, enabling the tracking of drug distribution from organs to single cells (Natarajan et al., 2015).”
From Spatial pharmacology of anti-cancer immunomodulators: a comprehensive review (2026) · cites this paper as Natarajan et al., 2015
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“For example, RLM revealed marked differences in rituximab binding between single cells, with some cells accumulating up to 1200 radionuclides per cell (Natarajan et al., 2015).”
From Spatial pharmacology of anti-cancer immunomodulators: a comprehensive review (2026) · cites this paper as Natarajan et al., 2015
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum dots versus organic dyes as fluorescent labels
Resch-Genger, U., Grabolle, M., Cavaliere-Jaricot, S., Nitschke, R., & Nann, T. (2008) · Nature Methods · doi:10.1038/nmeth.1248 · Cited by 3,833
Tumour stem cells and drug resistance
Dean, M., Fojo, T., & Bates, S. (2005) · Nature reviews. Cancer · doi:10.1038/nrc1590 · Cited by 3,668
Mechanisms of Cancer Drug Resistance
Gottesman, M. M. (2002) · Annual Review of Medicine · doi:10.1146/annurev.med.53.082901.103929 · Cited by 2,643
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,255
Live-cell imaging of alkyne-tagged small biomolecules by stimulated Raman scattering
Wei, L., Hu, F., Shen, Y., Chen, Z., Yu, Y., Lin, C.-C., Wang, M. C., & Min, W. (2014) · Nature Methods · doi:10.1038/nmeth.2878 · Cited by 504
Willingham, M. C., Cornwell, M. M., CARDARELLI, C. O., Gottesman, M. M., & Pastan, I. H. (1986) · PubMed · Cited by 305
Autoradiography, MALDI-MS, and SIMS-MS Imaging in Pharmaceutical Discovery and Development
Solon, E. G., Schweitzer, A., Stoeckli, M., & Prideaux, B. (2010) · The AAPS Journal · doi:10.1208/s12248-009-9158-4 · Cited by 250
Single-cell and subcellular pharmacokinetic imaging allows insight into drug action in vivo
Thurber, G. M., Yang, K. S., Reiner, T., Kohler, R. H., Sorger, P., Mitchison, T., & Weissleder, R. (2013) · Nature Communications · doi:10.1038/ncomms2506 · Cited by 194
Efficient Elimination of B-Lineage Lymphomas by Anti-CD20–Auristatin Conjugates
Law, C., Cerveny, C. G., Gordon, K. A., Klussman, K., Mixan, B. J., Chace, D. F., Meyer, D. L., Doronina, S. O., Siegall, C. B., Francisco, J. A., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1028 · Cited by 116
Laughney, A. M., Kim, E., Sprachman, M. M., Miller, M. A., Kohler, R. H., Yang, K. S., Orth, J. D., Mitchison, T. J., & Weissleder, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009318 · Cited by 77
Encyclopedia of Drug Metabolism and Interactions
(2011) · Wiley eBooks · doi:10.1002/9780470921920 · Cited by 76
Pratx, G., Chen, K., Sun, C., Martin, L. J., Carpenter, C. M., Olcott, P. D., & Xing, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046285 · Cited by 60
Self-citationThe performance of a CCD digital autoradiography imaging system
Ott, R. J., MacDonald, J. H., Wells, K., & Ott, R. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/7/322 · Cited by 50
Digital autoradiography using room temperature CCD and CMOS imaging technology
Cabello, J., Bailey, A., Kitchen, I., Prydderch, M. L., Clark, A. T., Turchetta, R. A. D., & Wells, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/16/019 · Cited by 50
Pratx, G., Chen, K., Sun, C., Axente, M., Sasportas, L. S., Carpenter, C. M., & Xing, L. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.113365 · Cited by 46
Self-citationNatarajan, A., Habte, F. G., & Gambhir, S. S. (2012) · Bioconjugate Chemistry · doi:10.1021/bc300039r · Cited by 42
Self-citationBioluminescence microscopy using a short focal‐length imaging lens
Ogoh, K., Akiyoshi, R., MAY‐MAW‐THET, Sugiyama, T., DOSAKA, S., Hatta‐Ohashi, Y., & Suzuki, H. (2014) · Journal of Microscopy · doi:10.1111/jmi.12109 · Cited by 41
Natarajan, A., Gowrishankar, G., Nielsen, C. H., Wang, S., Iagaru, A. H., Goris, M. L., & Gambhir, S. S. (2012) · Molecular Imaging and Biology · doi:10.1007/s11307-011-0537-8 · Cited by 41
Self-citationBright Lu2O3:Eu Thin‐Film Scintillators for High‐Resolution Radioluminescence Microscopy
Sengupta, D., Miller, S., Marton, Z., Chin, F. T., Nagarkar, V. V., & Pratx, G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500372 · Cited by 37
Self-citationRadionuclide targeting and dosimetry at the microscopic level: the role of microautoradiography
Puncher, M. R. B., & Blower, P. J. (1994) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02426701 · Cited by 33
Natarajan, A., & Gambhir, S. S. (2014) · Molecular Imaging and Biology · doi:10.1007/s11307-014-0810-8 · Cited by 29
Self-citationSingle-Cell Analysis of [18F]Fluorodeoxyglucose Uptake by Droplet Radiofluidics
Türkcan, S. C., Nguyen, J., Vilalta, M., Shen, B., Chin, F. T., Pratx, G., & Abbyad, P. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00792 · Cited by 22
Self-citation14C autoradiography with an energy-sensitive silicon pixel detector
Esposito, M., Mettivier, G., & Russo, P. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/7/003 · Cited by 19
Koshkin, V., & Krylov, S. N. (2011) · Analytical Chemistry · doi:10.1021/ac201690t · Cited by 15
Cited by
Cilliers, C., Nessler, I., Christodolu, N., & Thurber, G. M. (2017) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.6b01091 · Cited by 117
“8 Although experimental methods are approaching the cellular scale, 9 their resolution is intrinsically limited by the path length of the positron and imaging equipment.”
Subcellular Targeting of Theranostic Radionuclides
Bavelaar, B. M., Lee, B. Q., Gill, M. R., Falzone, N., & Vallis, K. A. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.00996 · Cited by 121
Modular low-light microscope for imaging cellular bioluminescence and radioluminescence
Kim, T. J., Türkcan, S. C., & Pratx, G. (2017) · Nature Protocols · doi:10.1038/nprot.2017.008 · Cited by 46
Self-citationDevelopment of trackable metal-based drugs: new generation of therapeutic agents
Bertrand, B., Doulain, P., Goze, C., & Bodio, E. (2016) · Dalton Transactions · doi:10.1039/c5dt04275e · Cited by 35
Optical Imaging of Ionizing Radiation from Clinical Sources
Shaffer, T. M., Drain, C. M., & Grimm, J. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.178624 · Cited by 33
“Although the prior examples were completed using in vitro samples, RLM was also used with ex vivo tissue samples, directly analogous to autoradiography (38).”
Method
Metadata
- Authors
- Natarajan, A., Türkcan, S., Gambhir, S. S., & Pratx, G.
- Affiliations
- Stanford Medicine (US)
- Stanford University School of Medicine , 1050 Arastradero Rd , , ,
- Corresponding author
- Pratx, Guillem
- Venue
- Molecular Pharmaceutics
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-10-13
- Volume
- 12
- Issue
- 12
- Pages
- 4554-4560
- ISSN
- 1543-8384 (ISSN-L)
- 1543-8392
- PMC
- PMC4674817
- OpenAlex
- W2409875238
- Cited by
- 19
- References
- 24
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 8 · 2016: 4
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Molecular Pharmaceutics (publishedVersion, other-oa)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Cancer Institute (R01CA186275)
- Congressionally Directed Medical Research Programs (W81XWH-14-1-0288)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Detection and Scintillator Technologies
- Keywords
- rituximab, zirconium-89, copper-64, positron emission tomography, single-cell imaging, non-Hodgkin lymphoma, CD20, splenic red pulp, chemoresistance, multiscale imaging
- MeSH terms
- Rituximab, Animals, Antineoplastic Agents, Autoradiography, Disease Models, Animal, Humans, Lymphoma, Non-Hodgkin, Mice, Transgenic, Radioisotopes, Tissue Distribution, Antigens, CD20, Radiopharmaceuticals, Positron-Emission Tomography, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.