Spontaneous Internalization of Cell Penetrating Peptide-Modified Nanowires into Primary Neurons
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Semiconductor nanowire (NW) devices that can address intracellular electrophysiological events with high sensitivity and spatial resolution are emerging as key tools in nanobioelectronics. Intracellular delivery of NWs without compromising cellular integrity and metabolic activity has, however, proven difficult without external mechanical forces or electrical pulses. Here, we introduce a biomimetic approach in which a cell penetrating peptide, the trans-activating transcriptional activator (TAT) from human immunodeficiency virus 1, is linked to the surface of Si NWs to facilitate spontaneous internalization of NWs into primary neuronal cells. Confocal microscopy imaging studies at fixed time points demonstrate that TAT-conjugated NWs (TAT-NWs) are fully internalized into mouse hippocampal neurons, and quantitative image analyses reveal an ca. 15% internalization efficiency. In addition, live cell dynamic imaging of NW internalization shows that NW penetration begins within 10-20 min after binding to the membrane and that NWs become fully internalized within 30-40 min. The generality of cell penetrating peptide modification method is further demonstrated by internalization of TAT-NWs into primary dorsal root ganglion (DRG) neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Self-citationWadia, J. S., Stan, R. V., & Dowdy, S. F. (2004) · Nature Medicine · doi:10.1038/nm996 · Cited by 1,647
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Self-citationSoft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Cited by
3D Arrays of 1024‐Pixel Image Sensors based on Lead Halide Perovskite Nanowires
Gu, L., Tavakoli, M. M., Zhang, D., Zhang, Q., Waleed, A., Xiao, Y., Tsui, K., Lin, Y., Liao, L., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201601603 · Cited by 300
High‐Aspect‐Ratio Nanostructured Surfaces as Biological Metamaterials
Higgins, S. G., Becce, M., Belessiotis‐Richards, A., Seong, H., Sero, J. E., & Stevens, M. M. (2020) · Advanced Materials · doi:10.1002/adma.201903862 · Cited by 256
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
“active detector areas that are much smaller than conventional passive electrodes, nanowire FETs are potential candidates for incorporation into mesh electronics to provide highly-localized detection of both extracellular and intracellular field/action potentials in vivo [26 ,52 ,53 ,54].”
Self-citationMesh nanoelectronics: seamless integration of electronics with tissues.
Dai, X., Hong, G., Gao, T., & Lieber, C. M. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00547 · Cited by 86
Self-citation
Metadata
- Authors
- Lee, J.-H., Zhang, A., You, S. S., & Lieber, C. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-12
- Volume
- 16
- Issue
- 2
- Pages
- 1509-1513
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2236337102
- Cited by
- 101
- References
- 6
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.