Cited by 274Plasmonic and Surface Plasmon ResearchGold and Silver Nanoparticles Synthesis and ApplicationsNear-Field Optical Microscopy

Nanogapped Au Antennas for Ultrasensitive Surface-Enhanced Infrared Absorption Spectroscopy

Dong, Liangliang, Yang, Xiao, Zhang, Chao, Cerjan, Benjamin, Zhou, Linan, Tseng, Ming Lun, Zhang, Yu, Alabastri, Alessandro +2 more·2017·Nano Letters

Abstract

Surface-enhanced infrared absorption (SEIRA) spectroscopy has outstanding potential in chemical detection as a complement to surface-enhanced Raman spectroscopy (SERS), yet it has historically lagged well behind SERS in detection sensitivity. Here we report a new ultrasensitive infrared antenna designed to bring SEIRA spectroscopy into the few-molecule detection range. Our antenna consists of a bowtie-shaped Au structure with a sub-3 nm gap, positioned to create a cavity above a reflective substrate. This three-dimensional geometry tightly confines incident mid-infrared radiation into its ultrasmall junction, yielding a hot spot with a theoretical SEIRA enhancement factor of more than 10 7, which can be designed to span the range of frequencies useful for SEIRA. We quantitatively evaluated the IR detection limit of this antenna design using mixed monolayers of 4-nitrothiophenol (4-NTP) and 4-methoxythiolphenol (4-MTP). The optimized antenna structure allows the detection of as few as ∼500 molecules of 4-NTP and ∼600 molecules of 4-MTP with a standard commercial FTIR spectrometer. This strategy offers a new platform for analyzing the IR vibrations of minute quantities of molecules and lends insight into the ultimate limit of single-molecule SEIRA detection.

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.7b02736

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Squeezing the gap between adjacent plasmonic nanoantennas to the nanometer scale increases electric field intensity but ruins sensing performance by decreasing active area and increasing fabrication cost.

    “The other method to improve the sensitivity is to increase the intensity of the electric field by squeezing the gap between adjacent PNA into the nanometer scale29–31. However, the narrow gap ruins the sensing performance by a decrement in the active area and increases fabrication cost.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dong, L., Yang, X., Zhang, C., Cerjan, B., Zhou, L., Tseng, M. L., Zhang, Y., Alabastri, A., Nordlander, P., & Halas, N. J.
Affiliations
Rice University (US)
Corresponding author
Halas, Naomi J.
Venue
Nano Letters
Published
2017-08-16
Volume
17
Issue
9
Pages
5768-5774
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2744183462
Cited by
274
References
50
Citations by year
2026: 15 · 2025: 38 · 2024: 33 · 2023: 28 · 2022: 32 · 2021: 30 · 2020: 30 · 2019: 36 · 2018: 32
FWCI
12.09
Type
journal article
Language
en
Open access
closed
Locations
  • Nano Letters (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Welch Foundation (C-1220, C-1222)
  • Army Research Office (W911NF-12-1-0407)
  • Air Force Office of Scientific Research (FA9550-15-1-0022)
  • Division of Electrical, Communications and Cyber Systems (ECCS-1610229)
  • Defense Threat Reduction Agency (HDTRA1-16-1-0042)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Near-Field Optical Microscopy
Keywords
surface-enhanced infrared absorption, bowtie nanoantennas, single-molecule detection, 4-nitrothiophenol, detection limit, chemical sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review