CoChat

Slit-Enhanced Chiral- and Broadband Infrared Ultra-Sensing

Knipper, Richard, Kopecký, Vladimír, Huebner, Uwe, Popp, Jürgen, Mayerhöfer, Thomas G. · 2018 · ACS Photonics

The DOI matches its Crossref record; 41 of the 42 references it cites were found in a registry or an index.

Abstract

This work demonstrates a membrane-based chiral plasmonic metamaterial with two plasmonic absorption bands which can be used for broadband surface-enhanced infrared absorption (SEIRA) and vibrational circular dichroism (VCD) sensing in the spectral range ∼1000–4000 cm–1 (SEIRA) and ∼2000–4000 cm–1 (VCD). Based on finite-difference time-domain simulations, the chiral plasmonic response was optimized for enhancement at around 3200 cm–1. Accordingly, the chiral cross-slit array was adjusted for application in conventional transmission measurement setups and covers an area of 1 mm2. Polyethylene was used as a model analyte to simulate the SEIRA broadband response and the results were compared with octadecanethiol measurements due to their spectral similarity. Signal enhancement was observed from 3000 cm–1 down to 1400 cm–1 by tuning the polarization of the incoming radiation. Due to the inherent chirality of the design, a strong VCD absorbance of 0.83 at ∼3500 cm–1 could be observed for the unloaded substrate. For substrates loaded with α-pinene, it was observed that this value even increased to more than unity and, in addition, direct enhancement of VCD could be achieved, although the VCD signal is not directly comparable with that of the neat substance. Since the substrate–analyte complex also shows a giant circular birefringence effect, most likely due to the formation of a chiral effective medium, it has great potential to be used as a sensor and may be applicable in a multitude of different scenarios in the analysis of biologic and pharmaceutic substances.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsphotonics.8b00476

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 41 references

Research works printed but not linked: 1

  1. Knipper, 2018, Observation of Giant Infrared Circular Dichroism in Plasmonic 2D-Metamaterial Arrays, ACS Photonics, 5, 1176, 10.1021/acsphotonics.8b00476

Cited by

See all 39

Metadata

Authors
Knipper, R., Kopecký, V., Huebner, U., Popp, J., & Mayerhöfer, T. G.
Affiliations
  • Leibniz Institute of Photonic Technology (DE)
  • Charles University , , Ke Karlovu 5 , 2, ,
  • Leibniz Institute of Photonic Technology (IPHT) , Albert-Einstein-Str. 9 , , ,
Venue
ACS Photonics
Published
2018-07-23
Volume
5
Issue
8
Pages
3238-3245
ISSN
2330-4022 (ISSN-L)
OpenAlex
W2884096448
Cited by
39
References
42
Citations by year
2026: 1 · 2025: 2 · 2024: 8 · 2023: 7 · 2022: 2 · 2021: 6 · 2020: 7 · 2019: 5 · 2018: 1
FWCI
1.90
Type
journal article
Language
en
Open access
closed
Locations
ACS Photonics (publishedVersion)
Funders
  • Bundesministerium f?r Bildung und Forschung (03IPT513Y)
  • Grantov? Agentura Cesk? Republiky (P205/12/G118)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
Keywords
surface-enhanced infrared absorption, vibrational circular dichroism, infrared detection, circular birefringence, octadecanethiol, α-pinene, polyethylene

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Slit-Enhanced Chiral- and Broadband Infrared Ultra-Sensing. https://app.cochat.ai/papers/10.1021/acsphotonics.8b00476
The paper
Knipper, R., Kopecký, V., Huebner, U., Popp, J., & Mayerhöfer, T. G. (2018). Slit-Enhanced Chiral- and Broadband Infrared Ultra-Sensing. ACS Photonics. https://doi.org/10.1021/acsphotonics.8b00476

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.