Soft and MRI Compatible Neural Electrodes from Carbon Nanotube Fibers
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Soft and magnetic resonance imaging (MRI) compatible neural electrodes enable stable chronic electrophysiological measurements and anatomical or functional MRI studies of the entire brain without electrode interference with MRI images. These properties are important for many studies, ranging from a fundamental neurophysiological study of functional MRI signals to a chronic neuromodulatory effect investigation of therapeutic deep brain stimulation. Here we develop soft and MRI compatible neural electrodes using carbon nanotube (CNT) fibers with a diameter from 20 μm down to 5 μm. The CNT fiber electrodes demonstrate excellent interfacial electrochemical properties and greatly reduced MRI artifacts than PtIr electrodes under a 7.0 T MRI scanner. With a shuttle-assisted implantation strategy, we show that the soft CNT fiber electrodes can precisely target specific brain regions and record high-quality single-unit neural signals. Significantly, they are capable of continuously detecting and isolating single neuronal units from rats for up to 4-5 months without electrode repositioning, with greatly reduced brain inflammatory responses as compared to their stiff metal counterparts. In addition, we show that due to their high tensile strength, the CNT fiber electrodes can be retracted controllably postinsertion, which provides an effective and convenient way to do multidepth recording or potentially selecting cells with particular response properties. The chronic recording stability and MRI compatibility, together with their small size, provide the CNT fiber electrodes unique research capabilities for both basic and applied neuroscience studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [315]
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Effect of Acid Treatment on Carbon Nanotube-Based Flexible Transparent Conducting Films
Geng, H.-Z., Kim, K. K., So, K. P., Lee, Y. S., Chang, Y., & Lee, Y. H. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0722224 · Cited by 925
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Research works printed but not linked: 2
- Finelli D. A., 2002, Am. J. Neuroradiol., 23, 1795
- Sakas D. E., 2007, Operative Neuromodulation: Vol. 2: Neural Networks Surgery
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Zhang, X., Lu, W., Zhou, G., & Li, Q. (2020) · Advanced Materials · doi:10.1002/adma.201902028 · Cited by 408
Self-citationFunctional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Soft bioelectronics for the management of cardiovascular diseases
Sunwoo, S.-H., Han, S. I., Park, C. S., Kim, J. H., Georgiou, J. S., Lee, S.-P., Kim, D.-H., & Hyeon, T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00102-z · Cited by 167
“Therefore, carbon-based nanomaterials can be applied for bioelectrodes 102–104 , and they can also be functionalized to serve as biochemical sensors 105,106 .”
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
“Carbon nanotubes (CNT) based Magnetic Resonance Imaging (MRI) compatible neural probes have also been developed to combine functional MRI (fMRI) studies across entire brain regions without any electrode interferences [99].”
Background
Metadata
- Authors
- Lu, L., Fu, X., Liew, Y., Zhang, Y., Zhao, S., Xu, Z., Zhao, J., Li, D., Li, Q., Stanley, G. B., & Duan, X.
- Affiliations
- Georgia Institute of Technology (US)
- Peking University (CN)
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia 30332, United States
- Chinese Academy of Sciences (CN)
- Corresponding author
- Stanley, Garrett B.
- Duan, Xiaojie
- ORCID
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-24
- Volume
- 19
- Issue
- 3
- Pages
- 1577-1586
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2916787787
- Semantic Scholar
- 1d4ed08c1d4642040f608e71402491748fddf059
- Cited by
- 146
- References
- 49
- Citations by year
- 2026: 20 · 2025: 25 · 2024: 17 · 2023: 22 · 2022: 23 · 2021: 24 · 2020: 13 · 2019: 2
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Nano Letters (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (91648207, 21422301)
- Ministry of Science and Technology of the People's Republic of China (2016YFA0200103, 2014CB932500)
- Beijing Graphene Innovation Program (Z161100002116028)
- Central People's Government of the People's Republic of China
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- carbon nanotube fibers, neural electrodes, MRI compatibility, soft electrodes, chronic neural recording, single-unit recording, neuroinflammation, deep brain stimulation, functional MRI, neuromodulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.