Soft and MRI Compatible Neural Electrodes from Carbon Nanotube Fibers
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Soft and magnetic resonance imaging (MRI) compatible neural electrodes enable stable chronic electrophysiological measurements and anatomical or functional MRI studies of the entire brain without electrode interference with MRI images. These properties are important for many studies, ranging from a fundamental neurophysiological study of functional MRI signals to a chronic neuromodulatory effect investigation of therapeutic deep brain stimulation. Here we develop soft and MRI compatible neural electrodes using carbon nanotube (CNT) fibers with a diameter from 20 μm down to 5 μm. The CNT fiber electrodes demonstrate excellent interfacial electrochemical properties and greatly reduced MRI artifacts than PtIr electrodes under a 7.0 T MRI scanner. With a shuttle-assisted implantation strategy, we show that the soft CNT fiber electrodes can precisely target specific brain regions and record high-quality single-unit neural signals. Significantly, they are capable of continuously detecting and isolating single neuronal units from rats for up to 4-5 months without electrode repositioning, with greatly reduced brain inflammatory responses as compared to their stiff metal counterparts. In addition, we show that due to their high tensile strength, the CNT fiber electrodes can be retracted controllably postinsertion, which provides an effective and convenient way to do multidepth recording or potentially selecting cells with particular response properties. The chronic recording stability and MRI compatibility, together with their small size, provide the CNT fiber electrodes unique research capabilities for both basic and applied neuroscience studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [315]
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Effect of Acid Treatment on Carbon Nanotube-Based Flexible Transparent Conducting Films
Geng, H.-Z., Kim, K. K., So, K. P., Lee, Y. S., Chang, Y., & Lee, Y. H. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0722224 · Cited by 925
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Zhang, X., Jiang, K., Feng, C., Liu, P., Zhang, L., Kong, J., Zhang, T., Li, Q., & Fan, S. (2006) · Advanced Materials · doi:10.1002/adma.200502528 · Cited by 604
Self-citationA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Hippocampal theta oscillations are travelling waves
Lubenov, E. V., & Siapas, A. G. (2009) · Nature · doi:10.1038/nature08010 · Cited by 540
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Deep brain stimulation restores frontostriatal network activity in obsessive-compulsive disorder
Figee, M., Luigjes, J., Smolders, R., Valencia-Alfonso, C.-E., van Wingen, G., de Kwaasteniet, B., Mantione, M., Ooms, P., de Koning, P., Vulink, N., et al. (2013) · Nature Neuroscience · doi:10.1038/nn.3344 · Cited by 466
The mechanobiology of brain function
Tyler, W. J. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3383 · Cited by 420
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
Neural Stimulation and Recording with Bidirectional, Soft Carbon Nanotube Fiber Microelectrodes
Vitale, F., Summerson, S. R., Aazhang, B., Kemere, C., & Pasquali, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b01060 · Cited by 311
Microseizures and the spatiotemporal scales of human partial epilepsy
Stead, M., Bower, M., Brinkmann, B. H., Lee, K., Marsh, W. R., Meyer, F. B., Litt, B., Van Gompel, J., & Worrell, G. A. (2010) · Brain · doi:10.1093/brain/awq190 · Cited by 311
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Liu, K., Sun, Y., Chen, L., Feng, C., Feng, X., Jiang, K., Zhao, Y., & Fan, S. (2008) · Nano Letters · doi:10.1021/nl0723073 · Cited by 274
Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.273 · Cited by 257
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 183
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Thalamic synchrony and the adaptive gating of information flow to cortex
Wang, Q., Webber, R. M., & Stanley, G. B. (2010) · Nature Neuroscience · doi:10.1038/nn.2670 · Cited by 166
Self-citationA comparison of the mechanical properties of fibers spun from different carbon nanotubes
Jia, J., Zhao, J., Xu, G., Di, J., Yong, Z., Tao, Y., Fang, C., Zhang, Z., Zhang, X., Zheng, L., et al. (2010) · Carbon · doi:10.1016/j.carbon.2010.11.054 · Cited by 158
Self-citationMechanism of Anesthesia Revealed by Shunting Actions of Isoflurane on Thalamocortical Neurons
Ries, C. R., & Puil, E. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1795 · Cited by 157
MR imaging-related heating of deep brain stimulation electrodes: in vitro study.
Finelli, D. A., Rezai, A. R., Ruggieri, P. M., Tkach, J. A., Nyenhuis, J. A., Hrdlicka, G., Sharan, A. D., Gonzalez-Martinez, J. A., Stypulkowski, P. H., & Shellock, F. G. (2002) · PubMed Central · Cited by 125
Electrophysiology and Functional MRI in Post-Acute Mild Traumatic Brain Injury
Gosselin, N., Bottari, C., Chen, J.-K., Petrides, M., Tinawi, S., de Guise, É., & Ptito, A. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1493 · Cited by 124
Effects of Anesthesia on BOLD Signal and Neuronal Activity in the Somatosensory Cortex
Aksenov, D. P., Li, L., Miller, M. J., Iordanescu, G., & Wyrwicz, A. M. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2015.130 · Cited by 113
Graphene Encapsulated Copper Microwires as Highly MRI Compatible Neural Electrodes
Zhao, S., Liu, X., Xu, Z., Ren, H., Deng, B., Tang, M., Lu, L., Fu, X., Peng, H., Liu, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b03829 · Cited by 108
Self-citationDouble‐Peak Mechanical Properties of Carbon‐Nanotube Fibers
Zhao, J., Zhang, X., Di, J., Xu, G., Yang, X., Liu, X., Yong, Z., Chen, M., & Li, Q. (2010) · Small · doi:10.1002/smll.201001120 · Cited by 100
Self-citationRecent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Magnetic and electronic properties of multiwall carbon nanotubes
Likodimos, V., Glenis, S., Guskos, N., & Lin, C. L. (2003) · Physical review. B, Condensed matter · doi:10.1103/physrevb.68.045417 · Cited by 67
Information Coding through Adaptive Gating of Synchronized Thalamic Bursting
Whitmire, C. J., Waiblinger, C., Schwarz, C., & Stanley, G. B. (2016) · Cell Reports · doi:10.1016/j.celrep.2015.12.068 · Cited by 62
Self-citationThani, N. B., Bala, A., Swann, G. B., & Lind, C. R. P. (2011) · Neurosurgery · doi:10.1227/neu.0b013e318218c7ae · Cited by 61
Isoflurane abolishes spontaneous firing of serotonin neurons and masks their pH/CO2chemosensitivity
Massey, C. A., Iceman, K. E., Johansen, S. L., Wu, Y., Harris, M. B., & Richerson, G. B. (2015) · Journal of Neurophysiology · doi:10.1152/jn.01073.2014 · Cited by 54
Antkowiak, B., & Helfrich-Forster, C. (1998) · Anesthesiology · doi:10.1097/00000542-199806000-00024 · Cited by 53
Mobin, F., Salles, A. A. F. D., Behnke, E., & Frysinger, R. C. (1999) · Stereotactic and Functional Neurosurgery · doi:10.1159/000029730 · Cited by 53
Syringe Injectable Electronics
Liu, J. (2017) · Springer theses · doi:10.1007/978-3-319-68609-7_5 · Cited by 47
Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study
Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875581 · Cited by 45
Metal artifacts caused by gradient switching
Graf, H., Steidle, G., Martirosian, P., Lauer, U. A., & Schick, F. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20524 · Cited by 42
Adaptive Movable Neural Interfaces for Monitoring Single Neurons in the Brain
Muthuswamy, J., Anand, S., & Sridharan, A. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00094 · Cited by 25
Artifact properties of carbon nanotube yarn electrode in magnetic resonance imaging
Jiang, C., Hao, H. W., & Li, L. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026013 · Cited by 22
Gradient field switching as a source for artifacts in MR imaging of metallic stents
Shenhav, A., & Azhari, H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20294 · Cited by 11
Antkowiak, B., Hentschke, H., & Kirschfeld, K. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.5.617 · Cited by 11
Research works printed but not linked: 2
- Finelli D. A., 2002, Am. J. Neuroradiol., 23, 1795
- Sakas D. E., 2007, Operative Neuromodulation: Vol. 2: Neural Networks Surgery
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Zhang, X., Lu, W., Zhou, G., & Li, Q. (2020) · Advanced Materials · doi:10.1002/adma.201902028 · Cited by 408
Self-citationFunctional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Soft bioelectronics for the management of cardiovascular diseases
Sunwoo, S.-H., Han, S. I., Park, C. S., Kim, J. H., Georgiou, J. S., Lee, S.-P., Kim, D.-H., & Hyeon, T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00102-z · Cited by 167
“Therefore, carbon-based nanomaterials can be applied for bioelectrodes 102–104 , and they can also be functionalized to serve as biochemical sensors 105,106 .”
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
“Carbon nanotubes (CNT) based Magnetic Resonance Imaging (MRI) compatible neural probes have also been developed to combine functional MRI (fMRI) studies across entire brain regions without any electrode interferences [99].”
Background
Metadata
- Authors
- Lu, L., Fu, X., Liew, Y., Zhang, Y., Zhao, S., Xu, Z., Zhao, J., Li, D., Li, Q., Stanley, G. B., & Duan, X.
- Affiliations
- Georgia Institute of Technology (US)
- Peking University (CN)
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia 30332, United States
- Chinese Academy of Sciences (CN)
- Corresponding author
- Stanley, Garrett B.
- Duan, Xiaojie
- ORCID
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-24
- Volume
- 19
- Issue
- 3
- Pages
- 1577-1586
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2916787787
- Semantic Scholar
- 1d4ed08c1d4642040f608e71402491748fddf059
- Cited by
- 146
- References
- 49
- Citations by year
- 2026: 20 · 2025: 25 · 2024: 17 · 2023: 22 · 2022: 23 · 2021: 24 · 2020: 13 · 2019: 2
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Nano Letters (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (91648207, 21422301)
- Ministry of Science and Technology of the People's Republic of China (2016YFA0200103, 2014CB932500)
- Beijing Graphene Innovation Program (Z161100002116028)
- Central People's Government of the People's Republic of China
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- carbon nanotube fibers, neural electrodes, MRI compatibility, soft electrodes, chronic neural recording, single-unit recording, neuroinflammation, deep brain stimulation, functional MRI, neuromodulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.