Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

NaCeF4:Gd,Tb Scintillator as an X-ray Responsive Photosensitizer for Multimodal Imaging-Guided Synchronous Radio/Radiodynamic Therapy

Zhong, Xiaoyan, Wang, Xianwen, Zhan, Guiting, Tang, Yong’an, Yao, Yuzhu, Dong, Ziliang, Hou, Linqian, Zhao, He, Zeng, Songjun, Hu, Jun, Cheng, Liang, Yang, Xiangliang·2019·Nano Letters

Abstract

Photosensitizers (PSs) that are directly responsive to X-ray for radiodynamic therapy (RDT) with desirable imaging abilities have great potential applications in cancer therapy. Herein, the cerium (Ce)-doped NaCeF 4:Gd,Tb scintillating nanoparticle (ScNP or scintillator) is first reported. Due to the sensitization effect of the Ce ions, Tb ions can emit fluorescence under X-ray irradiation to trigger X-ray excited fluorescence (XEF). Moreover, Ce and Tb ions can absorb the energy of secondary electrons generated by X-ray to produce reactive oxide species (ROS) for RDT. With the intrinsic absorption of X-ray by lanthanide elements, the NaCeF 4:Gd,Tb ScNPs also act as a computed tomography (CT) imaging contrast agent and radiosensitizers for radiotherapy (RT) sensitization synchronously. Most importantly, the transverse relaxation time of Gd 3+ ions is shortened due to the doping of Ce and Tb ions, leading to the excellent performance of our ScNPs in T 2 -weighted MR imaging for the first time. Both in vitro and in vivo studies verify that our synthesized ScNPs have good performance in XEF, CT, and T 2 -weighted MR imaging, and a synchronous RT/RDT is achieved with significant suppression on tumor progression under X-ray irradiation. Importantly, no systemic toxicity is observed after intravenous injection of ScNPs. Our work highlights that ScNPs have potential in multimodal imaging-guided RT/RDT of deep tumors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.9b03682

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 180

Metadata

Authors
Zhong, X., Wang, X., Zhan, G., Tang, Y., Yao, Y., Dong, Z., Hou, L., Zhao, H., Zeng, S., Hu, J., Cheng, L., & Yang, X.
Venue
Nano Letters
Published
2019-10-02
Volume
19
Issue
11
Pages
8234-8244
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2978788781
Cited by
180
References
5
FWCI
17.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: NaCeF4:Gd,Tb Scintillator as an X-ray Responsive Photosensitizer for Multimodal Imaging-Guided Synchronous Radio/Radiodynamic Therapy. https://app.cochat.ai/papers/10.1021/acs.nanolett.9b03682
The paper
Zhong, X., Wang, X., Zhan, G., Tang, Y., Yao, Y., Dong, Z., Hou, L., Zhao, H., Zeng, S., Hu, J., Cheng, L., & Yang, X. (2019). NaCeF4:Gd,Tb Scintillator as an X-ray Responsive Photosensitizer for Multimodal Imaging-Guided Synchronous Radio/Radiodynamic Therapy. Nano Letters. https://doi.org/10.1021/acs.nanolett.9b03682

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.